Page 92

Appendix

F

A–B

Scanner Commands Each label in this manual is preceded by two characters which represent the serial command for a scanner parameter. The following tables list the command mnemonic for each scanner parameter and the page location of the corresponding label. Mnemonic ZA ZB ZC @C @A @B AA AB AC AD BC BD NP NQ NO NN HA HE HF

General Scanner Setup Parameters Function Set Scanner to Factory Defaults Display Scanner Configuration Transmit Program Version Number Transmit Program ID Enable Full Continuous Power Enable Standby Power Beeper Off Beeper On; Volume Low Beeper On; Volume Medium Beeper On; Volume Loud Capture Count=1 Capture Count=2 Disable Spotter Beam Enable Spotter Beam Enable Autosense Mode Disable Autosense Mode Disable External Trigger External Trigger (+) External Trigger (–)

Page # 4-10 5-1 5-2 5-2 5-3 5-3 5-4 5-4 5-4 5-4 5-5 5-5 5-6 5-6 5-7 5-7 5-8 5-8 5-8

F–1

Page 93

Appendix F Scanner Commands

F–2

Mnemonic DA DB DC DD DE DF DG

Serial Communication Parameters Function Baud Rate = 300 Baud Rate = 600 Baud Rate = 1200 Baud Rate = 2400 Baud Rate = 4800 Baud Rate = 9600 Baud Rate = 19200

Page # 6-2 6-2 6-2 6-2 6-2 6-2 6-2

EA EB EC ED EE EF EG EH EI EJ EK EL EM EN HA HB HC HD HG HH HI HJ HK GA GB NE NF NG

7 Data Bits, 1 Stop Bit, Space Parity 7 Data Bits, 1 Stop Bit, Mark Parity 7 Data Bits, 1 Stop Bit, Even Parity 7 Data Bits, 1 Stop Bit, Odd Parity 7 Data Bits, 2 Stop Bits, Space Parity 7 Data Bits, 2 Stop Bits, Mark Parity 7 Data Bits, 2 Stop Bits, Even Parity 7 Data Bits, 2 Stop Bits, Odd Parity 8 Data Bits, 1 Stop Bit, Space Parity 8 Data Bits, 1 Stop Bit, Mark Parity 8 Data Bits, 1 Stop Bit, Even Parity 8 Data Bits, 1 Stop Bit, Odd Parity 8 Data Bits, 1 Stop Bit, No Parity 8 Data Bits, 2 Stop Bits, No Parity CTS Protocol = None Protocol = XON/XOFF Protocol = CTS(+) Protocol = CTS(–) RTS always high RTS always low RTS high means scanner has data to transmit RTS low means scanner has data to transmit RTS low means scanner ready to receive data No Intercharacter Delay Set Intercharacter Delay Serial Transmit Buffer = Full Buffering Serial Transmit Buffer = No Buffering Serial Transmit Buffer = One Label Buffering

6-4 6-4 6-4 6-4 6-5 6-5 6-5 6-5 6-6 6-6 6-6 6-6 6-5 6-6 6-8 6-8 6-8 6-8 6-9 6-9 6-9 6-9 6-9 6-10 6-10 6-11 6-11 6-11

Page 94

Appendix F Scanner Commands

Mnemonic IA IB IC MA MB MC MD ME MF JA JB FA FB KA KB LA LB

Message Format Parameters Function Prefix = None Prefix = STX Prefix = SOH Suffix=None Suffix = ETX Suffix = CR Suffix = LF Suffix = HT Suffix = CR and LF Disable Scanner Identifier Enable Scanner Identifier Disable Code Identifier Enable Code Identifier Preamble = None Preamble = 4 ASCII Characters Postamble = None Postamble = 4 ASCII Characters

Mnemonic OA OB OC OD OE OF OG OH OI QA QB QC

Symbology Parameters Function Disable Code 39 Enable Standard Code 39 Enable Full ASCII Code 39 Disable Modulo 43 Check Character Enable Modulo 43 Check Character Do Not Transmit Code 39 Start/Stop Characters Transmit Code 39 Start/Stop Characters Set Minimum Length for Code 39 Labels Set Maximum Length for Code 39 Labels Disable UPC (A and E) Enable UPC (A and E) with 2 or 5 Digit Supplements Enable UPC (A and E) without 2 or 5 Digit Supplements

Page # 7-2 7-2 7-2 7-3 7-3 7-3 7-3 7-3 7-3 7-4 7-4 7-5 7-5 7-7 7-7 7-7 7-7

Page # 8-2 8-2 8-2 8-3 8-3 8-3 8-3 8-4 8-4 8-5 8-5 8-5

F–3

Page 95

Appendix F Scanner Commands

Mnemonic QD QE QF QG QH QI QJ QK RA RB RC RD RE RF RG PA PB PC PD PE PF PG PH PI TA TB TC TD VA VB VC VD VE VF

F–4

Symbology Parameters (continued) Function Disable Transmission UPC Number System Digit Enable Transmission UPC Number System Digit Disable Transmission UPC Check Digit Enable Transmission UPC Check Digit Disable Expanded UPC-E Enable Expanded UPC-E Enable UPC to EAN Translation Disable UPC to EAN Translation Disable EAN/JAN (8 or 13) Enable EAN/JAN with 2 or 5 Digit Supplements Disable EAN/JAN without 2 or 5 Digit Supplements Disable Transmission EAN/JAN Number System Digit Enable Transmission EAN/JAN Number System Digit Disable Transmission EAN/JAN Check Digit Enable Transmission EAN/JAN Check Digit Disable Interleaved 2 of 5 Enable Interleaved 2 of 5 without Check Digit Enable Interleaved 2 of 5 with Check Digit Set Minimum Length for Interleaved 2 of 5 Labels Set Maximum Length for Interleaved 2 of 5 Labels Disable Standard 2 of 5 Enable Standard 2 of 5 Set Minimum Length for Standard 2 of 5 Labels Set Maximum Length for Standard 2 of 5 Labels Disable Code 128 Enable Code 128 Set Minimum Length for Code 128 Labels Set Maximum Length for Code 128 Labels Disable Codabar Enable Codabar Disable Transmission Codabar Start/Stop Characters Enable Transmission Codabar Start/Stop Characters Set Minimum Length for Codabar Labels Set Maximum Length for Codabar Labels

Page # 8-6 8-6 8-6 8-6 8-5 8-5 8-7 8-7 8-8 8-8 8-8 8-9 8-9 8-9 8-9 8-10 8-10 8-10 8-11 8-11 8-12 8-12 8-12 8-12 8-13 8-13 8-13 8-13 8-14 8-14 8-14 8-14 8-15 8-15