Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 11 of 16

Bulletin 2755 Hand-Held Scanner with RS-232 Option User Manual, pages 83 to 85

Pages 83 to 85 of 104: 10 - Specifications; A - Bar Code Text Symbols

The original document is the PDF (662 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Allen-Bradley 2755-G3

Page 83

Chapter

10

A–B

Specifications Hand-Held Scanners Catalog No. 2755-G3-D Catalog No. 2755-G6-D

Optical Nominal Scan Rate Wavelength (nominal) Maximum Pitch Maximum Skew Scanning Range Minimum Bar Width 6.0 mil (.15 mm) 7.5 mil (.19 mm) 10.0 mil (.25 mm) 15.0 mil (.38 mm) 20.0 mil (.51 mm) 40.0 mil (1.02 mm) 55.0 mil (1.40 mm)

35 scans/second 670 nm ±55 degrees ±65 degrees

Standard Range (2755-G3-D) 3.0 in - 5.0 in 7.6 cm - 12.7 cm 2.5 in - 7.5 in 6.4 cm - 19.0 cm 1.0 in - 10.0 in 2.5 cm - 25.4 cm 1.5 in - 14.0 in 3.8 cm - 35.6 cm 2.5 in - 18.0 in 6.4 cm - 45.7 cm 9.0 in - 25.0 in 22.9 cm - 63.5 cm 12.0 in - 30.0 in 30.5 cm - 76.2 cm

Scanning Range Autosense Mode

Long Range (2755-G6-D) N.A. N.A. N.A. 8.0 in - 22 in 20.3 cm - 55.9 cm 12 in - 36 in 30.5 cm - 91.4 cm 23 in - 60 in 58.4 cm - 152.4 cm 23 in - 66 in 58.4 cm - 167.6 cm

36 in (91.4 cm) maximum (to reflective label or tape)

Electrical Supply Voltage Current Consumption While Scanning Standby Power Continuous Full Power 1

4.75 to 14 VDC 200 mA maximum 100 maximum 200 mA maximum 1

Autosense mode automatically uses continuous full power. 10–1

Page 84

Chapter 10 Specifications

Mechanical Dimensions Inches Millimeters Weight LED Indicators Good Read Scanning

4.0(L) x 2.8(W) x 6.6(H) 102(L) x 71(W) x 168(H) 8.0 oz (0.23 kg) Green Yellow

Environmental Operating Temperature Storage Temperature Relative Humidity Electrostatic Discharge Drop Test Dust and Rain

0° to 122° F -18° to +50° C -40° to 158° F -40° to +70° C 5 to 95% (noncondensing) 15kv to any external surface 5 feet (1.27 meter) on concrete MIL STD 810D Sections 510.2I & 506.2II

Interface RS-232 Certification Dept. of Health and Class II laser product. Human Services (DHHS) Complies with DHHS radiation performance standards, 21 DFR subchapter J.

10–2

Page 85

A

Appendix

A–B

Bar Code Test Symbols Use the following labels to insure that your scanner is functioning properly. The only label the long range scanner can read below is the Interleaved 2-of-5 (15 mil) label.

A–1