Page 1 of Operating Instructions: CLV640 Bar Code Scanner, Advanced Line

Manual · Sick

Operating Instructions: CLV640 Bar Code Scanner, Advanced Line

Manual132 pagesPDF 7.9 MB

Operating instructions for the SICK CLV640 fixed-mount bar code scanner: installation, wiring, SOPAS-ET setup, maintenance and data sheets.

Download the PDF7.9 MB

Covers · 1 model

The models it covers

Summary

What is in it

SICK's operating instructions for the CLV640 Bar Code Scanner from its Advanced Line, offered as a line scanner, raster scanner or line scanner with oscillating mirror, with a front or side reading window. The manual covers safety, a quick start, the product and its operating methods, mechanical and electrical installation (serial, CAN, Ethernet, switching inputs and outputs), startup and configuration with the SOPAS-ET software, maintenance, troubleshooting, technical data, depth of field diagrams, dimensional drawings and ordering information.

Its parts

  1. Notes on this document
  2. Safety information
  3. Quick-Start
  4. Product description
  5. Installation
  6. Electrical installation
  7. Startup and configuration
  8. Maintenance
  9. Troubleshooting
  10. Technical data
  11. Appendix

From the manual

Key facts from this manual

Each line names its page in the PDF.

The SICK operating instructions from 2008 for the CLV640 Advanced Line bar code scanner, which has dynamic focus and comes as a line, raster or oscillating mirror scanner. It covers safety, the product and its indicators, mechanical and electrical installation, startup with the SOPAS-ET software, maintenance, troubleshooting, technical data and ordering information for accessories.

Read for this summary: pages 1 to 2, 26 to 28, 36 to 37, 79 to 83 and 111 to 116 of 132.

Device
Bar code scanner with dynamic focus position: line, raster or line with oscillating mirror; front or side reading window p. 28
Interfaces
Host: RS-232 or RS-422/485 (2.4 to 115.2 kbd) or Ethernet; Aux: RS-232 at 57.6 kbd or Ethernet; CAN 20 kBit/s to 1 MBit/s p. 81
Power
18 to 30 V DC; typically 5.5 W at 24 V DC, oscillating mirror version 6.5 W p. 82, 83
Connection
Standard version: 0.9 m cable with 15-pole D-Sub-HD plug; Ethernet version: revolving unit with two M12 connectors (12-pole plug, 4-pole socket) p. 82
Scan rate, resolution
400 to 1,200 Hz; resolution 0.20 to 1.0 mm, type-dependent p. 81
Temperature
Operating 0 to +40 °C; storage -20 to +70 °C p. 82
Light source
Red laser diode, 655 nm p. 81
Switching I/O
Standard version: 2 inputs and 2 PNP outputs (max. 100 mA); Ethernet version: 1 input, no output; 2 more of each via CMC600 in CDB620 p. 81, 82
Weight
Standard version: 320 g with cable (front window), 340 g (side); Ethernet version: 250 g (front), 270 g (side) p. 82
Variants
CLV640-0000 (1042014) line, front, cable; CLV640-0120 (1042015) line, front, connector unit; CLV640-6000 (1042022) and CLV640-6120 (1042023) oscillating mirror, side p. 27
Firmware, software
SICK firmware from v 1.0 0000; SOPAS-ET configuration software from v 2.16 p. 2
Connection modules
CDB620-001 (1042256) and CDM420-0001 (1025362); parameter memory module CMC600-101 (1042259) p. 112, 113
Cables
6034417 extension cable, 2 m, CLV640 to CDB620 or CDM420; 2014054 RS-232 null modem cable, 3 m, CLV640 to PC p. 115, 116
AC power module
CMP400 (2029468) for the CDM420: 100 to 250 VAC in, 24 V DC out, max. 10.8 W p. 113

What this manual walks you through

  • What comes in the box p. 26
  • Choosing a variant by scanning method, reading window and connection p. 27, 111
  • Reading the six housing LEDs and the bar graph p. 37
  • Configuring the scanner with SOPAS-ET or command strings p. 36
  • Finding installation, wiring and configuration errors p. 79
  • Viewing the status protocol in SOPAS-ET p. 80
  • Connecting to PROFIBUS DP or DeviceNet through CMF400 gateways or the CDF600 p. 113, 114
  • Ordering brackets, cables and connectors p. 111, 115, 116
  • Oscillating mirror modes and settings p. 83

Good to know

  • The scanner cannot be repaired by the user; it can be replaced, and repairs are for SICK service staff. p. 80
  • The Result 1 and Result 2 outputs exist only on the standard version; the Ethernet version needs a CDB620/CDM420 with CMC600. p. 36
  • The Micro SD card is not included, and only SICK approved cards should be used. p. 26
  • The status protocol keeps only the last five entries of each error type. p. 80
  • The manual states laser class 2 (IEC 60825-1 and EN 60825-1). p. 81

Questions this manual answers

What voltage does the SICK CLV640 need?

18 to 30 V DC; it draws typically 5.5 W at 24 V DC. p. 82

What does a red READY LED on the CLV640 mean?

The scanner has detected a hardware error. p. 37

Is a Micro SD card included with the CLV640?

No. The 512 MB Micro SD card for parameter cloning is optional. p. 26, 81

Which cable connects a CLV640 to a PC over RS-232?

The 3 m SICK null modem cable 2014054. p. 116

Can a faulty CLV640 be repaired on site?

No. The user cannot repair it, but can replace it quickly; contact SICK Service first. p. 80

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. 1 Notes on this document11
    1. 1.1 Purpose11
    2. 1.2 Target group11
    3. 1.3 Depth of information11
    4. 1.4 Used symbols12
  2. 2 Safety information13
    1. 2.1 Authorised users13
    2. 2.2 Intended use14
    3. 2.3 General safety precautions and protection measures14
    4. 2.4 Quick stop and quick restart17
    5. 2.5 Environmental information18
  3. 3 Quick-Start19
    1. 3.1 Preparing the bar code scanner for the quick start19
    2. 3.2 Establishing connection with the bar code scanner19
    3. 3.3 Performing the reading20
  4. 4 Product description23
    1. 4.1 Setting up the bar code scanner23
    2. 4.2 Included in delivery26
    3. 4.3 Device versions27
    4. 4.4 System requirements27
    5. 4.5 Product features and functions (overview)28
    6. 4.6 Bar code scanner methods of operation29
    7. 4.7 Indicators and control elements36
  5. 5 Installation41
    1. 5.1 Overview of installation sequences41
    2. 5.2 Installation preparations41
    3. 5.3 Installation location43
    4. 5.4 Installation of the bar code scanner48
    5. 5.5 Installing external components49
    6. 5.6 Removing the bar code scanner50
  6. 6 Electrical installation51
    1. 6.1 Overview of installation sequence51
    2. 6.2 Electrical installation preparation51
    3. 6.3 Electrical connections and cables52
    4. 6.4 Performing electrical installation56
    5. 6.5 Pin assignment and wire colour assignment of the assembled cables62
  7. 7 Startup and configuration65
    1. 7.1 Overview of the startup procedure65
    2. 7.2 SOPAS-ET configuration software65
    3. 7.3 Establish communication with the bar code scanner66
29 more lines, from page 68 on
  1. 7.4 First startup68
    1. 7.5 Default setting70
    2. 7.6 Adjusting the bar code scanner71
  2. 8 Maintenance73
    1. 8.1 Maintenance during operation73
    2. 8.2 Cleaning the bar code scanner73
    3. 8.3 Cleaning further optical effective surfaces76
    4. 8.4 Checking the incremental encoder76
    5. 8.5 Replacing a bar code scanner76
  3. 9 Troubleshooting79
    1. 9.1 Overview of errors and malfunctions which could occur79
    2. 9.2 Detailed malfunction analysis79
    3. 9.3 Status protocol80
    4. 9.4 SICK Support80
  4. 10 Technical data81
    1. 10.1 Datenblatt Barcodescanner CLV640 (Linien-/ Rasterscanner)81
    2. 10.2 Data sheet for the CLV640 Bar Code Scanner (line scanner with oscillating mirror)83
    3. 10.3 Specification diagrams84
    4. 10.4 CLV640 Bar Code Scanner dimensional drawings102
  5. 11 Appendix109
    1. 11.1 Appendix overview109
    2. 11.2 Configuring the bar code scanner with command strings109
    3. 11.3 Calculating the code length of a bar code110
    4. 11.4 Ordering information for bar code scanner and accessories111
    5. 11.5 Dimensional drawing accessories117
    6. 11.6 Supplementary documentation121
    7. 11.7 Glossary122
    8. 11.8 EC Declaration of Conformity130
    9. 11.9 Code samples of bar codes (selection)131

From the PDF’s own bookmarks.

The whole text · 15 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 101-10
  2. Pages 11 to 1811-18
  3. 3 Quick-Start19-22
  4. 4 Product description, pages 23 to 3123-31
  5. 4 Product description, pages 32 to 4032-40
  6. 5 Installation41-50
  7. 6 Electrical installation51-64
  8. 7 Startup and configuration65-72
  9. 8 Maintenance73-78
  10. Pages 79 to 8879-88
  11. Pages 89 to 9889-98
  12. Pages 99 to 10899-108
  13. 11 Appendix, pages 109 to 116109-116
  14. 11 Appendix, pages 117 to 124117-124
  15. 11 Appendix, pages 125 to 132125-132

The file

Revision and size

Revision8011975/0000/2008-04-14
PublisherSICK AG
Pages132
PDF7.9 MB
TextText from the PDF itself; page 132 is a scan, read by OCR, which may hold reading errors.

The first pages · 3 of 132

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 132
Page 2
Page 2of 132
Page 3
Page 3of 132

More documents · 1

For the same models