Manual · Sick
Operating Instructions: CLV640 Bar Code Scanner, Advanced Line
Manual132 pagesPDF 7.9 MB
Operating instructions for the SICK CLV640 fixed-mount bar code scanner: installation, wiring, SOPAS-ET setup, maintenance and data sheets.
Covers · 1 model
The models it covers
Summary
What is in it
SICK's operating instructions for the CLV640 Bar Code Scanner from its Advanced Line, offered as a line scanner, raster scanner or line scanner with oscillating mirror, with a front or side reading window. The manual covers safety, a quick start, the product and its operating methods, mechanical and electrical installation (serial, CAN, Ethernet, switching inputs and outputs), startup and configuration with the SOPAS-ET software, maintenance, troubleshooting, technical data, depth of field diagrams, dimensional drawings and ordering information.
Its parts
- Notes on this document
- Safety information
- Quick-Start
- Product description
- Installation
- Electrical installation
- Startup and configuration
- Maintenance
- Troubleshooting
- Technical data
- Appendix
From the manual
Key facts from this manual
Each line names its page in the PDF.
The SICK operating instructions from 2008 for the CLV640 Advanced Line bar code scanner, which has dynamic focus and comes as a line, raster or oscillating mirror scanner. It covers safety, the product and its indicators, mechanical and electrical installation, startup with the SOPAS-ET software, maintenance, troubleshooting, technical data and ordering information for accessories.
- Device
- Bar code scanner with dynamic focus position: line, raster or line with oscillating mirror; front or side reading window p. 28
- Interfaces
- Host: RS-232 or RS-422/485 (2.4 to 115.2 kbd) or Ethernet; Aux: RS-232 at 57.6 kbd or Ethernet; CAN 20 kBit/s to 1 MBit/s p. 81
- Power
- 18 to 30 V DC; typically 5.5 W at 24 V DC, oscillating mirror version 6.5 W p. 82, 83
- Connection
- Standard version: 0.9 m cable with 15-pole D-Sub-HD plug; Ethernet version: revolving unit with two M12 connectors (12-pole plug, 4-pole socket) p. 82
- Scan rate, resolution
- 400 to 1,200 Hz; resolution 0.20 to 1.0 mm, type-dependent p. 81
- Temperature
- Operating 0 to +40 °C; storage -20 to +70 °C p. 82
- Light source
- Red laser diode, 655 nm p. 81
- Switching I/O
- Standard version: 2 inputs and 2 PNP outputs (max. 100 mA); Ethernet version: 1 input, no output; 2 more of each via CMC600 in CDB620 p. 81, 82
- Weight
- Standard version: 320 g with cable (front window), 340 g (side); Ethernet version: 250 g (front), 270 g (side) p. 82
- Variants
- CLV640-0000 (1042014) line, front, cable; CLV640-0120 (1042015) line, front, connector unit; CLV640-6000 (1042022) and CLV640-6120 (1042023) oscillating mirror, side p. 27
- Firmware, software
- SICK firmware from v 1.0 0000; SOPAS-ET configuration software from v 2.16 p. 2
- Connection modules
- CDB620-001 (1042256) and CDM420-0001 (1025362); parameter memory module CMC600-101 (1042259) p. 112, 113
- Cables
- 6034417 extension cable, 2 m, CLV640 to CDB620 or CDM420; 2014054 RS-232 null modem cable, 3 m, CLV640 to PC p. 115, 116
- AC power module
- CMP400 (2029468) for the CDM420: 100 to 250 VAC in, 24 V DC out, max. 10.8 W p. 113
What this manual walks you through
- What comes in the box p. 26
- Choosing a variant by scanning method, reading window and connection p. 27, 111
- Reading the six housing LEDs and the bar graph p. 37
- Configuring the scanner with SOPAS-ET or command strings p. 36
- Finding installation, wiring and configuration errors p. 79
- Viewing the status protocol in SOPAS-ET p. 80
- Connecting to PROFIBUS DP or DeviceNet through CMF400 gateways or the CDF600 p. 113, 114
- Ordering brackets, cables and connectors p. 111, 115, 116
- Oscillating mirror modes and settings p. 83
Good to know
- The scanner cannot be repaired by the user; it can be replaced, and repairs are for SICK service staff. p. 80
- The Result 1 and Result 2 outputs exist only on the standard version; the Ethernet version needs a CDB620/CDM420 with CMC600. p. 36
- The Micro SD card is not included, and only SICK approved cards should be used. p. 26
- The status protocol keeps only the last five entries of each error type. p. 80
- The manual states laser class 2 (IEC 60825-1 and EN 60825-1). p. 81
Questions this manual answers
What voltage does the SICK CLV640 need?
18 to 30 V DC; it draws typically 5.5 W at 24 V DC. p. 82
What does a red READY LED on the CLV640 mean?
The scanner has detected a hardware error. p. 37
Is a Micro SD card included with the CLV640?
No. The 512 MB Micro SD card for parameter cloning is optional. p. 26, 81
Which cable connects a CLV640 to a PC over RS-232?
The 3 m SICK null modem cable 2014054. p. 116
Can a faulty CLV640 be repaired on site?
No. The user cannot repair it, but can replace it quickly; contact SICK Service first. p. 80
Contents
Chapters and sections
Each line opens the PDF at its page.
- 1 Notes on this document11
- 2 Safety information13
- 3 Quick-Start19
- 4 Product description23
- 5 Installation41
- 6 Electrical installation51
- 7 Startup and configuration65
29 more lines, from page 68 on
- 7.4 First startup68
- 8 Maintenance73
- 9 Troubleshooting79
- 10 Technical data81
- 11 Appendix109
- 11.1 Appendix overview109
- 11.2 Configuring the bar code scanner with command strings109
- 11.3 Calculating the code length of a bar code110
- 11.4 Ordering information for bar code scanner and accessories111
- 11.5 Dimensional drawing accessories117
- 11.6 Supplementary documentation121
- 11.7 Glossary122
- 11.8 EC Declaration of Conformity130
- 11.9 Code samples of bar codes (selection)131
The whole text · 15 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
- Pages 1 to 101-10
- Pages 11 to 1811-18
- 3 Quick-Start19-22
- 4 Product description, pages 23 to 3123-31
- 4 Product description, pages 32 to 4032-40
- 5 Installation41-50
- 6 Electrical installation51-64
- 7 Startup and configuration65-72
- 8 Maintenance73-78
- Pages 79 to 8879-88
- Pages 89 to 9889-98
- Pages 99 to 10899-108
- 11 Appendix, pages 109 to 116109-116
- 11 Appendix, pages 117 to 124117-124
- 11 Appendix, pages 125 to 132125-132
The file