Page 32

Chapter 4

Product description

Operating Instructions CLV640 Bar Code Scanner

Trigger sources for the switch-over are: •

Signal at the switching input "Sensor 2" for the max. 2-pole switching

•

Command from the host interface or the integrated timer (e.g. search run) for the max. 8-pole switch-over

•

Reversal points of oscillation mirror for the bilateral deflection on the line scanner with oscillating mirror chapter 4.6.4 Oscillating mirror control, page 32

The distance configurations of the switching order are assigned via the programmable cross-reference list. Note

The focus position can be configured using the SOPAS-ET configuration software: PROJECT TREE, CLV640, PARAMETER, READING CONFIGURATION PROJECT TREE, CLV640, PARAMETER, READING CONFIGURATION, OSCILLATING MIRROR PROJECT TREE, CLV640, PARAMETER, READING CONFIGURATION, FOCUS CONTROL PROJECT TREE, CLV640, PARAMETER, READING CONFIGURATION, DYNAMIC READING CONFIGURATION 4.6.4

Oscillating mirror control

You can manipulate the position of the scanning line for the line scanner with oscillating mirror (CLV640-6000/CLV640-6120) by configuring the oscillating mirror. In addition to parking (fixed scanning line position which can be adjusted) or continuous oscillation independent of the reading pulse, controlled operation of the oscillating mirror also enables optimised operation sequences related to the reading pulse: • n-fold oscillation around an adjustable start position within the reading pulse

•

One-shot: one-time deflection (forward and return) per reading pulse from an adjustable start position

In every oscillation mode, the amplitude can be adjusted separately for each of the two deflection directions. The deflection speed ratio of one deflection direction to the other can be adjusted within the selected periodic time for the entire oscillation sequence.

Fig. 4-5:

32

CLV640 Oscillating Mirror: Example of focal position control in search run, here with 6 focus positions

© SICK AG · Division Auto Ident · Germany · All rights reserved

8011975/0000/2008-04-14

Page 33

Operating Instructions

Product description

Chapter 4

CLV640 Bar Code Scanner

Note

The behaviour or the position of the oscillating mirror can be configured via the SOPAS-ET configuration software: PROJECT TREE, CLV640, PARAMETER, READING CONFIGURATION, OSCILLATING MIRROR, register tab OSCILLATING MIRROR 4.6.5

Increment configuration

The bar code scanner receives information about the conveyor speed from an external incremental encoder, for example. The incremental encoder delivers pulses which are used to determine the current conveyor speed. The conveyor speed results from the number of impulses and the resolution of the external incremental encoder. Note

The increment source and the resolution/speed can be configured using the SOPAS-ET configuration software: PROJECT TREE, CLV640, PARAMETER, INCREMENT CONFIGURATION, register tab INCREMENT

4.6.6

Code configuration

The bar code scanner can decode the following code types: •

Codabar

•

Code 39

•

UPC/EAN

•

2/5 Interleaved

•

Code 93

•

Code 128 family

•

Pharmacode

Note

The code types can be selected and configured using the SOPAS-ET configuration software: PROJECT TREE, CLV640, PARAMETER, CODE CONFIGURATION, register tab SYMBOLOGIES The selected code types can be configured individually. For this purpose, separate register tabs are available in the configuration software SOPAS-ET.

8011975/0000/2008-04-14

© SICK AG · Division Auto Ident · Germany · All rights reserved

33

Page 34

Chapter 4

Product description

Operating Instructions CLV640 Bar Code Scanner

4.6.7

Reading operation mode

There is only one object in the reading field during start/stop operation, i.e. all the read codes should be unambiguously assigned to the object. The start and stop of the reading process control one/two reading pulse sensors at the beginning and at the end of the reading field as standard. The distance between each sensor is determined by the size of the reading field. The reading process can be alternatively controlled with command strings via the data interface. The output of the reading results is carried out either at the end of the reading pulse (the rear edge of the object has left the end of the reading field) or during the reading pulse if certain configurable conditions have been fulfilled.

Fig. 4-6:

Reading operation mode for the CLV640 Bar Code Scanner in stand-alone operation

Note

The reading operation mode can be configured using the SOPAS-ET configuration software: PROJECT TREE, CLV640, PARAMETER, DATA PROCESSING, register tab TRACKING

4.6.8

Data processing

Note

The output time in the reading process with regard to the reading pulse start can be configured using the SOPAS-ET configuration software: PROJECT TREE, CLV640, PARAMETER, DATA PROCESSING, OUTPUT CONTROL Furthermore, the evaluation conditions and filters and sorters for data output to the host computer can be configured: PROJECT TREE, CLV640, PARAMETER, DATA PROCESSING, EVALUATION CONDITION PROJECT TREE, CLV640, PARAMETER, DATA PROCESSING, FILTER/SORTER FOR OUTPUT 4.6.9

Output format

The reading result (decoded codes) is displayed via selectable physical interfaces. Two different output formats (telegrams) can be defined for this task, one format for "No Read" and one for the heartbeat (signalisation of readiness). Note

The output formats can be configured using the SOPAS-ET configuration software: PROJECT TREE, CLV640, PARAMETER, DATA PROCESSING, OUTPUT FORMAT

34

© SICK AG · Division Auto Ident · Germany · All rights reserved

8011975/0000/2008-04-14

Page 35

Operating Instructions

Product description

Chapter 4

CLV640 Bar Code Scanner

4.6.10

Network / interface / IOs

All important interfaces for displaying the reading results are available on the bar code scanner. Several bar code scanners can be connected to each other via the CAN bus in the SICK-specific CAN-SENSOR network. Note

The network parameters can be configured using the SOPAS-ET configuration software: PROJECT TREE, CLV640, PARAMETER, NETWORK / INTERFACE / IOS, tab pages NETWORK OPTIONS

4.6.11

Data interfaces

The following data interfaces are available on the bar code scanner depending on the version: Data interface

Function

Host interface (RS-232 or RS-422/485 and Ethernet host port)

Preparation of the reading result for further processing by the host processor

Auxiliary interface (RS-232 and Ethernet aux port)

Reading diagnosis or host interface monitoring

CAN

Networking several bar code scanners

Tab. 4-4:

Data interface function

Note

The data interfaces can be configured using the SOPAS-ET configuration software: PROJECT TREE, CLV640, PARAMETER, NETWORK / INTERFACE / IOS, SERIAL PROJECT TREE, CLV640, PARAMETER, NETWORK / INTERFACE / IOS, ETHERNET PROJECT TREE, CLV640, PARAMETER, NETWORK / INTERFACE / IOS, CAN 4.6.12

Digital inputs

The external sensor for the object triggering (photoelectric reflex switch) and the incremental encoder, e.g., can be connected to the digital switching inputs. Note

The digital inputs can be configured using the SOPAS-ET configuration software: PROJECT TREE, CLV640, PARAMETER, NETWORK / INTERFACE / IOS, DIGITAL INPUTS

Important

8011975/0000/2008-04-14

The connection "Sensor 2" is only available on the standard version of the bar code scanner. For the Ethernet version of the bar code scanner, this input is only available with the connection module CDB620/CDM420 in combination with the parameter memory module CMC600.

© SICK AG · Division Auto Ident · Germany · All rights reserved

35

Page 36

Product description

Chapter 4

Operating Instructions CLV640 Bar Code Scanner

4.6.13

Digital outputs

With certain events in the reading process (e.g. for unsuccessful decoding "No Read"), two independent switch signals can be generated at both digital outputs and can be used, e.g., to display the event status. Note

The digital outputs can be configured using the SOPAS-ET configuration software: PROJECT TREE, CLV640, PARAMETER, NETWORK / INTERFACE / IOS, DIGITAL OUTPUTS

Important

The switching outputs "Result 1" and "Result 2" are only available on the standard version of the bar code scanner. For the Ethernet version of the bar code scanner, the two outputs are only available with the connection module CDB620/CDM420 in combination with the parameter memory module CMC600.

4.7

Indicators and control elements

4.7.1

User interface

The bar code scanner is configured application-specifically using the SOPAS-ET configuration software (see chapter 7.4.1 Overview of the startup procedure, page 68). The software for this runs on a PC which must be connected to one of the two data interfaces (aux interface: Ethernet or RS-232, host interface: RS-232/RS-422/485 or Ethernet) of the bar code scanner. As an alternative to the SOPAS-ET configuration software, command strings are available upon which the user interface of the SOPAS-ET configuration software is based (see chapter 11.2 Configuring the bar code scanner with command strings, page 109). In case of an error, startup and diagnosis can be carried out via the SOPAS-ET configuration software. The bar code scanner operates fully automated in normal operation.

36

© SICK AG · Division Auto Ident · Germany · All rights reserved

8011975/0000/2008-04-14

Page 37

Operating Instructions

Product description

Chapter 4

CLV640 Bar Code Scanner

4.7.2

LEDs on the bar code scanner's housing

The bar code scanner's housing has six LEDs that display the operating status, the laser diode's activity, the status of the reading result and the transfer to the RS-232/RS-422/485, CAN and Ethernet interfaces. In reading operation the LEDs indicate the following: LED

Colour

Meaning

READY

Green

• Lights up constantly after switching on and a successful self-test • Goes out when parameter values are being uploaded from or downloaded to the bar code scanner

Red

• Lights up when a hardware error has been detected

RESULT

Green

• Lights up after a successful read (Good Read, 100 ms)

LASER

Green

• Reading operation: Lights up when the laser diode is switched on (depends on the reading pulse)

DATA

Green

• Lights up during the data transfer for 100 ms

CAN

Yellow

• Flickers during the data transfer via the CAN interface

LNK TX

Green

• Lights up when the physical Ethernet connection is o.k.

Bar graph (0 ... 100%)

Green

• LED´s light up according to the reading rate during diagnostic mode.

• During normal reading mode the bar graph display is switched off.

Tab. 4-5:

LED indications

Important

8011975/0000/2008-04-14

The “Result“ LED is not coupled with one of the “Result 1“ or "Result 2" outputs.

© SICK AG · Division Auto Ident · Germany · All rights reserved

37

Page 38

Product description

Chapter 4

Operating Instructions CLV640 Bar Code Scanner

4.7.3

Buttons on the bar code scanner housing

There are two yellow buttons on the bar code scanner housing in the LED area (see chapter 4.1.1 Device view, page 24). You can call up predefined functions via these buttons. After changing to the button operating mode you can select one function each by repeatedly pressing the lower button. By pressing the upper button, you can start or stop the selected function. The "TeachIn" function (for matchcode) and "Auto-Setup" stop the bar code scanner automatically. Currently you cannot call up user-defined functions. The selected function is shown via the corresponding LED below the buttons. When using both of the buttons the LEDs have different meanings than in normal reading operation:

Tab. 4-6:

LED

Colour

Function

Read Diagn

Green

Flashes slowly: the "Reading diagnosis/evaluation" function is selected Flashes rapidly: the "Reading diagnosis/evaluation" function is started

TeachIn

Green

Flashes slowly: the "TeachIn matchcode" function is selected Flashes rapidly: the "TeachIN matchcode" function is started

Auto-Setup

Green

Flashes slowly: the "Auto-Setup" function is selected Flashes rapidly: the "Auto-Setup" function is started

Adjust

Green

Flashes slowly: the "Adjusting" function is selected Flashes rapidly: the "Adjusting" function is started

Userdefined

Yellow

(momentarily not available)

Meaning of the LEDs during activation of buttons

Important

When using the buttons, the "Laser" LED's function differs from its original function in reading operation, the display of the switched-on laser diode. Use of the buttons In order to use one of the possible function with the buttons, do as follows: 1.

Press the upper button for approx. 3 seconds. The bar code scanner stops the current reading operation, switches off the LEDs and the bargraph display and changes to the button operating mode. With immediate effect the bar code scanner ignores all the other external reading pulses. No reading results are displayed via the host interface. The beeper confirms this process with an ascending melody. The "Read Diagn" function is pre-selected as first function (LED flashes slowly).

2.

Repeatedly press the lower button until the LED of the required function flashes. The bar code scanner scans all the possible functions successively without starting them and starts over. The beeper confirms each step with a sound.

3.

Press the upper button once to start the selected function. The LED flashes faster and the beeper confirms the start with two sounds.

38

© SICK AG · Division Auto Ident · Germany · All rights reserved

8011975/0000/2008-04-14

Page 39

Operating Instructions

Product description

Chapter 4

CLV640 Bar Code Scanner

4.

Press the upper button again to stop the function. The LED flashes more slowly again and the beeper confirms the end with two sounds. The bar code scanner stops the "TeachIn" (for matchcode) and "Auto-Setup" function automatically, when the presented bar code was read successfully. During this procedure, the "Ready" LED flashes in green three times and the beeper confirms it with an ascending melody.

5.

In order to return from the button operating mode to the reading operation, press the upper button again for approx. 3 seconds. The beeper confirms the change with a descending melody. The "Ready" LED lights up again. The bar code scanner is ready for reading and waits for a reading pulse.

Further behaviour of the bar code scanner when operated by buttons

8011975/0000/2008-04-14

•

Changing into button operating mode is only possible if no other user is logged onto the bar code scanner for changing the parameters via the SOPAS-ET configuration software. If this is the case, however, a descending melody is started by the beeper when trying to change into the button operating mode. The bar code scanner remains in reading operation.

•

In case a user logs onto the bar code scanner in button operating mode, the bar code scanner leaves the button operating mode and restarts the reading operation. The beeper confirms the change with a descending melody.

•

If no function is started in button operating mode or if no button operation can be performed after using a function, the bar code scanner returns into reading operation automatically after 30 seconds. The beeper confirms the change with a descending melody.

•

The bar code scanner terminates an activated continous function 5 minutes after start. It returns to reading operation automatically. The beeper confirms the change with a descending melody.

•

If the bar code scanner could not read the bar code in the "TeachIN" (for matchcode) as well as "Auto-Setup" functions, the "Ready" LED flashes in red for three times. The beeper reports this with a descending melody. After this the bar code scanner remains in button operating mode.

•

You cannot switch off or turn down the beeper in button operating mode.

© SICK AG · Division Auto Ident · Germany · All rights reserved

39

Page 40

Product description

Chapter 4

Operating Instructions CLV640 Bar Code Scanner

4.7.4

Parameter set on the Micro SD memory card (optional)

The bar code scanner stores configured parameter values in the internal PROM as well as on the Micro SD memory card (cloning), provided that this card has been inserted into the bar code scanner. If the bar code scanner needs to be replaced, the memory card enables easy and quick transfer of the parameter set to the new device (see chapter 8.5 Replacing a bar code scanner, page 76). Important

In order to avoid data loss, the Micro SD memory card may only be removed and inserted into the new device after the respective bar code scanner has been switched off and deenergized. When inserting the memory card, make sure that the contacts point backwards and upwards (towards the inscription "mircoSD" on the box slot). The memory card is located behind a black rubber cover attached to the bar code scanner.

Fig. 4-7:

Micro SD memory card for storing the parameter set

Important

To maintain the enclosure rating IP 65, the black rubber cover has to be closed and lie flush against the device. As an alternative to the Micro SD memory card in the bar code scanner, the external, optional parameter memory module CMC600 in connection module CDB620/CDM420 may also be used for storing the parameter set. If both the Micro SD memory card and the parameter memory module CMC600 are available, the bar code scanner will load the parameter set from the CMC600.

40

© SICK AG · Division Auto Ident · Germany · All rights reserved

8011975/0000/2008-04-14