Page 41

Operating Instructions

Installation

Chapter 5

CLV640 Bar Code Scanner

5

Installation 5.1

Overview of installation sequences

This chapter describes the installation sequences for the bar code scanner and its external components. The typical installation sequences are displayed below:

Important

•

Changing the language of the laser warning sign (if necessary)

•

Selecting the installation location for the bar code scanner

•

Aligning the bar code scanner to the object carrying the bar code

•

Installing the bar code scanner

•

Installing connection module CDB620 or CDM420

•

Connecting the bar code scanner to connection module CDB620 or CDM420

•

Adjusting the bar code scanner

•

Installing the reading pulse sensor for reading pulse triggering

Do not open the bar code scanner's housing. If the device is opened, the SICK AG warranty shall not apply.

5.2

Installation preparations

The following general requirements should be observed for installation: •

Typical space requirement: application specific

•

Unobstructed view of the objects for the bar code scanner

•

Stable installation bracket with sufficient load capacity and measurements suited to the bar code scanner (see chapter 10.4 CLV640 Bar Code Scanner dimensional drawings, page 102)

•

Shock absorbent and vibration free attachment

The following tools and resources are required for installation: •

Two M5 bolts: To fix bracket no. 2020410, quick release clamp no. 2025526 or fix bracket no. 2042800 to the base. The bolt length depends on the wall thickness of the base.

•

Laser warning sign set (if necessary)

•

Tool

•

Tape measure (up to 1 m (3.28ft))

•

Goniometer

5.2.1

Components to be installed

The following components have to be placed ready for installation: •

8011975/0000/2008-04-14

CLV640 Bar Code Scanner

© SICK AG · Division Auto Ident · Germany · All rights reserved

41

Page 42

Chapter 5

Installation

Operating Instructions CLV640 Bar Code Scanner

5.2.2

Accessories

The following accessories are not included in the delivery of the bar code scanner. They have to be ordered separately and placed ready for installation: •

Mounting device, see next chapter

•

Connection module CDB620 or CDM420

•

Reading pulse sensor for external reading pulse triggering, e. g. photoelectric reflex switch/photoelectric proximity switch

5.2.3

Mounting device

The bar code scanner is fixed using two blind hole taps (M5) that are each located on the narrow sides of the device chapter 10.4 CLV640 Bar Code Scanner dimensional drawings, page 102. The bar code scanner can be mounter using the following SICK holders: •

Bracket no. 2020410

•

Quick release clamp no. 2025526

•

Bracket no. 2042800

•

Round rod holder no. 2042801

The construction of the angle with adapter plate no. 2042800 supports e. g. varied mounting options and the alignment of the bar code scanner in two axis.

Fig. 5-1:

Example: Fixing the bar code scanner with the bracket no. 2042800

The dimensioning of the SICK-holders is shown in chapter 11.5 Dimensional drawing accessories, page 117. Alternatively, the user can provide a holder. The holder should meet the following requirements: •

Stable mounting device – Adjustable alignment of the bar code scanner in the x and y axis – The mounting device must be able to bear the weight of the bar code scanner including its connection cable (depending on the device version) without vibrating.

•

Two M5 bolts to fix the bar code scanner. – The screw length depends on the thickness of the mounting device. – The maximum thread reach in the bar code scanner is 5 mm (0.2 in) from the housing surface.

42

© SICK AG · Division Auto Ident · Germany · All rights reserved

8011975/0000/2008-04-14

Page 43

Operating Instructions

Installation

Chapter 5

CLV640 Bar Code Scanner

5.2.4

Exchanging the laser warning sign

The laser warning on the bar code scanner must be in a language that the operators of the unit in which the bar code scanner is integrated can understand. A set of self-adhesive laser warning signs German/American English and French/American English is included in the delivery. ¾

If necessary, replace the English laser warning sign before operating the bar code scanner.

Fig. 5-2:

5.3

Exchanging the laser warning sign

Installation location

The following aspects are relevant for the selection of the installation location: •

Allocation of the scanning line for the bar code

•

Reading distance to the bar code and aperture angle α

•

Angle alignment of the bar code scanner

•

Avoiding surface reflections

•

Counting direction of the reading angle (position of the bar code along the scanning line)

Furthermore, the distance between the bar code scanner and the host computer and the distance to the connection module has to be taken into account (see chapter 6.2 Electrical installation preparation, page 51 and chapter 5.5.1 Installing connection module CDB620 or CDM420, page 49).

8011975/0000/2008-04-14

© SICK AG · Division Auto Ident · Germany · All rights reserved

43

Page 44

Chapter 5

Installation

Operating Instructions CLV640 Bar Code Scanner

5.3.1

Allocation of the scanning line for the bar code

The main allocation of the scanning line to the bar code on the object depends on the version of the bar code scanner (line scanner, raster scanner or line scanner with oscillating mirror).

Fig. 5-3:

Allocation of the scanning line(s) for the bar code and conveyor system

5.3.2

Reading distance to the bar code and aperture angle α

The maximum distance between the bar code scanner's reading window and the bar code must not exceed the device-specific thresholds. The usable length of the scanning line that is used for the evaluation (reading area height) depends on the reading distance because of the V-shaped deflection of the beam.

Fig. 5-4:

Definition of the reading distance a and the aperture angle α

In the specification diagrams (chapter 10.3 Specification diagrams, page 84) the depth of field is shown depending on the adjustable focus position and the aperture angles used for various resolutions (modul widths).

44

© SICK AG · Division Auto Ident · Germany · All rights reserved

8011975/0000/2008-04-14

Page 45

Operating Instructions

Installation

Chapter 5

CLV640 Bar Code Scanner

5.3.3

Angle alignment of the bar code scanner

The bar code scanner is optimally aligned if the scanning line almost scans the lines of the bar code in the right-hand angle (90°). Possible code positions that can occur between the scanning line and bar code in all three levels in the room have to be taken into account. β

α

γ

α Azimuth angle (tilt) β Inclination angle (pitch) γ Step angle (skew) a Reading distance b Reading range Fig. 5-5:

Angle

Threshold

Azimuth α (tilt)

max. 30° (resolution 0.35 mm (13.8 mil), depending on the print image)

Inclination β (pitch)

max. 45° (depending on module width)

Step angle γ (skew)

max. 45° (depending on module width)

Tab. 5-1:

8011975/0000/2008-04-14

Line scanner: Reading angles that occurs between the scanning line and bar code

Permitted reading angles between the scanning line and bar code

© SICK AG · Division Auto Ident · Germany · All rights reserved

45

Page 46

Chapter 5

Installation

Operating Instructions CLV640 Bar Code Scanner

5.3.4

Avoiding surface reflections

If the light of the scanning line(s) vertically meets the surface of the bar code, this can result in disruptive reflections when the bounced back light is received. To prevent this effect, the bar code scanner must be installed in such a way that the light emitted is tilted down relative to the plumb line.

Fig. 5-6:

Avoiding surface reflection using the line scanner as an example: Angle between emitting light and bar code (tilted away from the plumb line)

5.3.5

Counting direction of the reading angle and code angle

The bar code scanner can scan and decode several bar codes with every read. The location-related reading diagnosis data is determined: •

The reading angle from the reading window to the red scanning line of the deflected scanning beam under which the middle of a bar code is detected can be displayed as an RA (reading angle) value.

•

In addition, with the line scanner with oscillating mirror, the deflection angle of the scanning line under which the bar code scanner detects the bar code on the red scanning line can be displayed as a CW value.

The determination of the RA/CW value enables identical bar codes (code type, code length and data contents) to be separated and the bar code data to be assigned to their position on the object.

46

© SICK AG · Division Auto Ident · Germany · All rights reserved

8011975/0000/2008-04-14

Page 47

Operating Instructions

Installation

Chapter 5

CLV640 Bar Code Scanner

Fig. 5-7:

Counting direction of the reading angle RA within the scanning line and of the code angle CW with the oscillating mirror

8011975/0000/2008-04-14

© SICK AG · Division Auto Ident · Germany · All rights reserved

47

Page 48

Chapter 5

Installation

Operating Instructions CLV640 Bar Code Scanner

5.4

Installation of the bar code scanner

5.4.1

Installing the bar code scanner

Damage to the device! The maximum thread reach of the two blind hole taps M5 is 5 mm (0.2 in). Longer bolts will damage the device. ¾

Use bolts of a suitable length.

1.

Preparing base for the installation of the bar code scanner holder, see chapter 5.2.2 Accessories, page 42.

2.

Place the object with the bar code at the designated position where the reading should be taken in the bar code scanner's visual range (no conveyor movement).

3.

Visually align the bar code scanner to the bar code. Pay attention to the following points: – With the bar code scanner with the front reading window, ensure that the narrow reverse side of the device with the laser warning sign is facing the viewer and is approximately parallel to the bar code plane. – With the bar code scanner with the side reading window, respectively the line scanner with oscillating mirror, ensure that the wide side panel with the LEDs is facing the viewer and is approximately parallel with the bar code plane. – During the reading, consider the reading angle, see chapter 5.3.3 Angle alignment of the bar code scanner, page 45. – If the bar code's position within the scanning line is relevant for the evaluation, observe the reading angle's counting direction, see chapter 5.3.5 Counting direction of the reading angle and code angle, page 46.

48

4.

Installing the bar code scanner holder on the base.

5.

Screw M5 bolts through the holder and into the bar code scanner's blind hole taps and gently tighten them.

6.

Adjusting the bar code scanner, see chapter 7.6.1 Adjusting the bar code scanner, page 71.

© SICK AG · Division Auto Ident · Germany · All rights reserved

8011975/0000/2008-04-14

Page 49

Operating Instructions

Installation

Chapter 5

CLV640 Bar Code Scanner

5.5

Installing external components

5.5.1

Installing connection module CDB620 or CDM420

Depending on the application, you can install either connection module CDB620 or CDM420. The installation process is the same for both modules. Important

If the PC with the SOPAS-ET configuration software accesses the bar code scanner's auxiliary interface (RS-232; 57.6 kbd) via the connection module, the connection module should not be installed more than 3 m (9.84 ft) cable lengths away from the bar code scanner. 1.

Install the connection module close to the bar code scanner.

2.

Install the connection module in such a way that the opened device can be accessed at any time.

Important

For detailed information about installation and electrical installation, see the operating instructions "Connection Module CDB620“ (no. 8012119, German/English) or "Connection Module CDM420-0001“ (no. 8010004, German/English). 5.5.2

Installing the external reading pulse sensor

If the bar code scanner is triggered by an external reading pulse sensor (photoelectric reflex switch), the sensor has to be installed close to the bar code scanner. Bar code scanner in the middle or at the end of the conveyed material b

Fig. 5-8:

Bar code scanner at the beginning of the conveyed material b< a b b< a

Line scanner: Installation example for positioning the external reading pulse sensor

The installation location depends on the distance (a) of the bar code to the front edge of the object. Depending on the application, the sensor should be attached in such a way that bar codes on different sized objects can be fully read during the evaluation (reading gate). 5.5.3

Installing the incremental encoder

An incremental encoder is required for separating bar codes with the same code type and identical content. The increment impulses have to come from the conveyor system area where the bar code scanner is reading.

8011975/0000/2008-04-14

1.

Install suitable increment encoders near to the bar code scanner, best against the direction of the conveyor system in front of the bar code scanner.

2.

Ensure that the incremental encoder has direct and fixed contact with the drive system and that the friction wheel rotates without slipping.

© SICK AG · Division Auto Ident · Germany · All rights reserved

49

Page 50

Chapter 5

Installation

Operating Instructions CLV640 Bar Code Scanner

5.6

Removing the bar code scanner

Removal of the components is described in chapter 8.5.1 Removing the bar code scanner, page 76.

50

© SICK AG · Division Auto Ident · Germany · All rights reserved

8011975/0000/2008-04-14