Page 51

Operating Instructions

Electrical installation

Chapter 6

CLV640 Bar Code Scanner

6

Electrical installation 6.1 Important

Overview of installation sequence

Electrical installation must be performed by qualified staff. The following list provides an overview of a typical installation sequence: •

Connecting the bar code scanner to connection module CDB620 or CDM420

•

Wiring the bar code scanner's data and function interfaces

•

Connecting the connection module to the supply voltage

•

Connecting a PC for start-up and configuration (RS-232 or Ethernet)

The actual installation work which has to be carried out depends on the respective system configuration and the version of the bar code scanner (see chapter 6.2 Electrical installation preparation, page 51). Once electrical installation has been completed, the bar code scanner is started up and configured (see chapter 7 Startup and configuration, page 65).

6.2

Electrical installation preparation

The following general requirements should be observed for the electrical installation: •

Supply voltage 18 ... 30 V DC (functional extra-low voltage in accordance with IEC 3644-41 (VDE 0100 Part 410)) and min. 10 W output power – Using connection module CDB620/CDM420: supply voltage provided by terminals of the connection module - or – Free wiring by customer (without connection module CDB620/CDM420): connection of supply voltage e.g. by cable no. 6034418 (15-pole D-Sub-HD socket to open end)

•

With external reading pulsing – Appropriate reading pulse sensor (start/stop), e. g. photoelectric reflex switch: for registering an object in the reading area – Additional appropriate reading pulse sensor (stop), e.g. photoelectric reflex switch: For registering the end of pulse with extended external reading pulse

Important

•

Appropriate incremental encoder: For separating identical bar codes

•

Host computer with RS-232, RS-422/485 data interface or Ethernet: For further processing the reading data

•

Connection cables: See chapter 11.4.7 Accessories: Cables for Ethernet version, page 115

The possible distance between the bar code scanner and the host computer depends on the physical version of the selected host interface and the set data transfer rate. The following tools and resources are required for electrical installation:

8011975/0000/2008-04-14

•

Tool

•

Digital measuring device (current/voltage measurement)

© SICK AG · Division Auto Ident · Germany · All rights reserved

51

Page 52

Chapter 6

Electrical installation

Operating Instructions CLV640 Bar Code Scanner

6.3

Electrical connections and cables

Fig. 6-1:

Standard version: Electrical connections at the bar code scanner with connection cable

Fig. 6-2:

Ethernet version: Electrical connections at the bar code scanner with connector unit

52

© SICK AG · Division Auto Ident · Germany · All rights reserved

8011975/0000/2008-04-14

Page 53

Operating Instructions

Electrical installation

Chapter 6

CLV640 Bar Code Scanner

6.3.1 Important

Electrical connections at the bar code scanner

Prerequisites for enclosure rating IP 65: •

The black rubber cover of the memory card (optional) has to be closed and lie flush against the device.

•

The connectors attached to the used electrical connections of the Ethernet version have to be firmly screwed.

The same applies to the EMC requirement (ESD) according to CE. Depending on the device version, the following electrical connections are available at the bar code scanner: Device version

Connection (design)

Interfaces

CLV640-0000 CLV640-1000 CLV640-2000 CLV640-3000 CLV640-6000

Cable with connector (D-Sub-HD, 15-pole, plug)

e. g. connection mod• RS-232 ule CDB620 or • RS-422/485 CDM420 • CAN • Two digital inputs • Two digital outputs • Power supply

Tab. 6-1:

8011975/0000/2008-04-14

Electrical connections to the bar code scanner with a fixed cable and connector (standard version)

Device version

Connection (design)

Interfaces

For connection to

CLV640-0120 CLV640-1120 CLV640-2120 CLV640-3120 CLV640-6120

Connector 1 at the connector unit (M-12, 4-pole, socket)

• Ethernet

Network provided by the client

Connector 2 at the connector unit M-12, 12-pole, plug

• RS-232 • RS-422/485 • CAN • One digital input • Power supply e. g. connection module CDB620 or CDM420

Tab. 6-2:

Important

For connection to

Electrical connections to the bar code scanner with connector unit (Ethernet version)

Additional digital inputs and outputs are available at connection module CDB620/CDM420 (available from week 07/2008) in combination with the parameter memory module CMC600.

© SICK AG · Division Auto Ident · Germany · All rights reserved

53

Page 54

Chapter 6

Electrical installation

Operating Instructions CLV640 Bar Code Scanner

6.3.2

Bar code scanner connections to the cable and connector (standard version)

6 1

11

15

Pin

Signal

Function

1

18 ... 30 V DC

Operating voltage

2

RxD (Aux)

Aux interface (receiver)

3

TxD (Aux)

Aux interface (sender)

4

Sensor 2

Digital switching input (adjustable function, e. g. external reading pulse)

5

GND

Ground

6

RD+ (RS-422/485)

Host interface (receiver)

7

RD– (RS-422/485); RxD (RS-232)

Host interface (receiver)

8

TD+ (RS-422/485)

Host interface (sender)

9

TD– (RS-422/485); TxD (RS-232)

Host interface (sender)

10

CAN H

CAN bus (IN/OUT)

11

CAN L

CAN bus (IN/OUT)

12

Result 1

Digital switching output, adjustable function

13

Result 2

Digital switching output, adjustable function

14

Sensor 1

Digital switching input for external reading pulse

15

SensGND

Common ground for the switching inputs

-

–

Shield

Tab. 6-3:

Standard version: Pin assignment of the 15-pole D-Sub-HD cable connector

6.3.3

Bar code scanner's connections with connector unit (Ethernet version)

Pin

Signal

Function

1

TD+

Transmitter+

2

RD+

Receiver+

3

TD-

Transmitter-

4

RD-

Receiver-

-

-

Shield

Tab. 6-4:

54

5 10

Ethernet version: Pin assignment of the 4-pole M12 socket

© SICK AG · Division Auto Ident · Germany · All rights reserved

8011975/0000/2008-04-14

Page 55

Operating Instructions

Electrical installation

Chapter 6

CLV640 Bar Code Scanner

Pin

Signal

Function

1

GND

Ground

2

18 ... 30 V DC

Operating voltage

3

CAN L

CAN bus (IN/OUT)

4

CAN H

CAN bus (IN/OUT)

5

TD+ (RS-422/485)

Host interface (sender)

6

TD– (RS-422/485); TxD (RS-232)

Host interface (sender)

7

TxD (Aux)

Aux interface (sender)

8

RxD (Aux)

Aux interface (receiver)

9

SensGND

Switching input Sensor 1 ground

10

Sensor 1

Digital switching input (external reading pulse)

11

RD+ (RS-422/485)

Host interface (receiver)

12

RD– (RS-422/485); RxD (RS-232)

Host interface (receiver)

-

–

Shield

Tab. 6-5:

Important

8011975/0000/2008-04-14

Ethernet version: Pin assignment on the 12-pole M12 plug

The "Sensor 2", "Result 1" and "Result 2" connections are only available on the bar code scanner with a cable and connector (standard version) and for the Ethernet version via the CDB620/CDM420 connection module in combination with the parameter memory module CMC600.

© SICK AG · Division Auto Ident · Germany · All rights reserved

55

Page 56

Electrical installation

Chapter 6

Operating Instructions CLV640 Bar Code Scanner

6.4 Important

Performing electrical installation

To ensure secure fastening of the connected connectors and adherence to the enclosure rating, the knurled nuts/coupling rings of the M12 connectors have to be tightened or the cable connectors have to be secured. 1.

Connect or release current linkages only under de-energised conditions.

2.

All wire cross sections and their shields on customer side have to be selected and implemented according to valid engineering standards.

Damage to the connector unit at the bar code scanner due to overwinding. The connector unit at the bar code scanner has two end positions. ¾

Never turn the connector unit more than 180° in one direction (comming from one of the end positions).

¾

Always rotate the connector unit in the direction of the laser diode name.

Fig. 6-3:

6.4.1

Direction of rotation of the connector unit

Connecting the power supply for the bar code scanner

The bar code scanner requires a supply voltage of 18 ... 30 V DC (functional extra-low voltage in accordance with IEC 364-4-41 (VDE 0100 (Part 410)) for operation. The functional extra-low voltage can be created using a safety transformer in accordance with IEC 742 (VDE 0551). The maximum current consumption is 6.5 W. The bar code scanner is supplied with 18 ...30 V DC via connection module CDB620 or CDM420. If the power supply module CMP400/CMP490 is used, the input voltage is 100 ... 250 V AC/ 50 ... 60 Hz at the module.

Important

56

The output circuit must be electrically separated from the input circuit. This is usually created by means of a safety transformer in accordance with IEC 742 (VDE 0551).

© SICK AG · Division Auto Ident · Germany · All rights reserved

8011975/0000/2008-04-14

Page 57

Operating Instructions

Electrical installation

Chapter 6

CLV640 Bar Code Scanner

Connecting supply voltage When wiring the bar code scanner using connection module CDB620 or CDM420, the bar code scanner's data and function interfaces are contacted to the connection module together with the power supply. 1.

Ensure that the connection module's supply voltage has been switched off.

2.

Standard version: Connect the bar code scanner's 15-pole cable plug to the connection module's 15-pole socket and screw it tight. - or Ethernet version: Connect the bar code scanner's 12-pole plug via a corresponding cable (e.g. 2042916) to the connection module's 15-pole socket and screw it tight.

6.4.2

Wiring serial data interfaces

The maximum data transfer rate depends on the cable length and the interface type. Interface type

Transfer rate

RS-232 up to 19,200 Bd max. 10 m (32.8 ft)

38,400 ... 57,600 Bd max. 3 m (9.8 ft)

115,200 Bd max. 2 m (6.6 ft)

max. 38,400 Bd max. 1,200 m (3,937 ft)

max. 115,200 Bd max. 500 m (1,640 ft)

RS-422/485

1)

Distance to the host

1) With corresponding line termination according to specification

Tab. 6-6:

8011975/0000/2008-04-14

Recommended maximum cable lengths, depending on the selected data transfer rate

© SICK AG · Division Auto Ident · Germany · All rights reserved

57

Page 58

Chapter 6

Electrical installation

Operating Instructions CLV640 Bar Code Scanner

RS-232 CLV

Host

CLV

Host

RS-422

Fig. 6-4:

Wiring the serial host data interfaces (RS-232 or RS-422) on the 15-pole D-Sub-HD plug

Pin assignment for the serial auxiliary data interface on the 15-pole D-Sub-HD plug: •

RxD = Pin 2

•

TxD = Pin 3

•

GND = Pin 5

Damage to the interface module! Incorrect wiring of the serial data interfaces can damage electronic components in the bar code scanner. ¾

Observe information about wiring the serial data interface.

¾

Check the wiring carefully before switching on the bar code scanner.

1.

Connect the bar code scanner's serial interface to the host in accordance with the EMC regulations using shielded cables. Adhere to the maximum cable lengths.

2.

To prevent interference, do not lay cables parallel to power supply cables and motor lines over a longer distance, e. g. in cable channels.

Important

Terminating the RS-422 data interface Termination can be performed either in connection module CDB620 or CDM420. See operating instructions "Connection module CDB620" or "Connection module CDM420".

58

© SICK AG · Division Auto Ident · Germany · All rights reserved

8011975/0000/2008-04-14

Page 59

Operating Instructions

Electrical installation

Chapter 6

CLV640 Bar Code Scanner

6.4.3

Wiring CAN interface

Important

To wire and configure the bar code scanner's CAN interface for use in the CAN-SENSOR-network, see the operating instructions "Using the CAN Interface“ (no. 8009180, English). 6.4.4

Wiring Ethernet interface

Aux and host interface communication can also be executed in parallel via the Ethernet interface.

$X[ +RVW

&$1

(WKHUQHW

Fig. 6-5:

Important

Function of the Ethernet interface

The Ethernet interface has an auto-MDIX function. This automatically sets the speed and any cross connection that is required. 6.4.5

Wiring switching inputs

If the bar code scanner's reading process should be triggered by an external sensor, the reading pulse sensor is connected to the "Sensor 1" switching input.

Fig. 6-6:

8011975/0000/2008-04-14

Wiring the “Sensor 1“ switching input on the 15-pole D-Sub-HD plug

© SICK AG · Division Auto Ident · Germany · All rights reserved

59

Page 60

Electrical installation

Chapter 6

Operating Instructions CLV640 Bar Code Scanner

The "Sensor 2" switching input has the following functions, among others: Trigger source for •

Incremental encoder input

•

Reading pulse generator for reading pulse end

Fig. 6-7:

Important

Wiring the "Sensor 2" switching input on the 15-pole D-Sub-HD plug

The ratings for "Sensor 1" and "Sensor 2" are identical. Switching behaviour

Power fed to the input opens the internal reading gate of the bar code scanner. (Default setting: active high; debouncing: max. 30 ms (standard))

Features

– Optodecoupled, reverse polarity protected – Can be wired with the PNP output of a sensor

Electrical values

Low: |Vin| ≤ 2 V; |Iin| ≤ 0.3mA High: 6 V ≤ |Vin| ≤ 32 V; 0.7 mA ≤ |Iin| ≤ 5.0 mA

Tab. 6-7:

¾

Ratings for the switching inputs

Connect switching inputs depending on application.

Important

To wire the switching inputs using connection module CDB620 or CDM420, see operating instructions "Connection Module CDB620" (no. 8012119, German/English) or "Connection Module CDM420-0001" (no. 8010004, German/English).

60

© SICK AG · Division Auto Ident · Germany · All rights reserved

8011975/0000/2008-04-14

Page 61

Operating Instructions

Electrical installation

Chapter 6

CLV640 Bar Code Scanner

6.4.6

Wiring switching outputs

The two switching outputs "Result 1" and "Result 2" can be allocated various functions for outputting the result status independently of each other. If the assigned result occurs in the reading process, the corresponding switching output at the end of the reading pulse is live for the selected impulse duration. Important

The "result" LED is not coupled with one of the "result" outputs.

Fig. 6-8:

Important

The ratings of the two switching outputs are identical. Switching behaviour

PNP switching against the distribution voltage VS

Features

Short-circuit proof + temperature-protected, Galvanically not separate from VS

Electrical values

0 V ≤ Vout ≤ VS Guaranteed: (VS −1.5 V) ≤ Vout ≤ VS with Iout ≤ 100 mA

Tab. 6-8:

Important

Possible wiring of the "Result 1" switching output on the 15-pole D-Sub-HD plug

Ratings for the switching outputs

Capacitance loads at the switching output affect the switching behaviour. Threshold is a max. capacitance of 100 nF. Exeeding this value can lead to unwanted pulsing behaviour of the output. 1.

Connect switching outputs depending on application.

2.

Wire the switching outputs with a load resistance to test the switching functions using a high-resistance digital voltmeter. Indication of incorrect voltages/switching statuses is avoided this way.

Important

To wire the switching outputs using connection module CDB620 or CDM420, see the operating instructions "Connection Module CDB620" (no. 8012119, German/English) or "Connection Module CDM420-0001" (no. 8010004, German/English).

8011975/0000/2008-04-14

© SICK AG · Division Auto Ident · Germany · All rights reserved

61

Page 62

Chapter 6

Electrical installation

Operating Instructions CLV640 Bar Code Scanner

6.5

Pin assignment and wire colour assignment of the assembled cables

6.5.1

Pin assignment of the assembled cables

Cable no. 6034414, 6029630, 6034415, 6030928 (Ethernet version)

Pin (4-pole)

Signal

Function

Pin (6-pole)

1

TD+

Transmitter+

1

3

TD-

Transmitter-

2

2

RD+

Receiver+

3

-

-

4

-

-

5

4

RD-

Receiver-

6

-

-

Shield

-

Tab. 6-9:

Pin assignment of the 4-pole M12 plug and the 6-pole RJ45 plug

Cable no. 2042916, 2041834, 2042914, 2042915 (Ethernet version)

Pin (12-pole) Signal

Function

Pin (15-pole)

2

18 ... 30 V DC

Operating voltage

1

8

RxD (Aux)

Aux interface (receiver)

2

7

TxD (Aux)

Aux interface (sender)

3

-

-

-

4

1

GND

Ground

5

11

RD+ (RS-422/485)

Host interface (receiver)

6

12

RD– (RS-422/485); RxD (RS-232)

Host interface (receiver)

7

5

TD+ (RS-422/485)

Host interface (sender)

8

6

TD– (RS-422/485); TxD (RS-232)

Host interface (sender)

9

4

CAN H

CAN bus (IN/OUT)

10

3

CAN L

CAN bus (IN/OUT)

11

-

-

-

12

-

-

-

13

10

Sensor 1

Digital switching input for external reading pulse

14

9

SensGND

Common ground for the switching 15 inputs

-

–

Shield

Tab. 6-10:

62

-

Pin assignment of the 12-pole M12 socket and the 15-pole D-Sub-HD plug

© SICK AG · Division Auto Ident · Germany · All rights reserved

8011975/0000/2008-04-14

Page 63

Operating Instructions

Electrical installation

Chapter 6

CLV640 Bar Code Scanner

6.5.2

Pin assignment and wire colour assignment of the assembled cables with an open end

Cable no. 6034605 (Ethernet version)

Pin (12-pole) Signal

Function

Wire colour

1

GND

Ground brown

2

18 ... 30 V DC

Operating voltage blue

3

CAN L

CAN bus (IN/OUT)

white

4

CAN H

CAN bus (IN/OUT)

green

5

TD+ (RS-422/485)

Host interface (sender)

pink

6

TD– (RS-422/485); TxD (RS-232)

Host interface (sender)

yellow

7

TxD (Aux)

Aux interface (sender)

black

8

RxD (Aux)

Aux interface (receiver)

grey

9

SensGND

Common ground for the switching inputs red

10

Sensor 1

Digital switching input for external reading pulse violet

11

RD+ (RS-422/485)

Host interface (receiver)

grey-pink

12

RD– (RS-422/485); RxD (RS-232)

Host interface (receiver)

red-blue

Tab. 6-11:

Pin assignment of the 12-pole M12 socket and wire colours at the open end

Cable no. 6012166

Pin (5-pole)

Function

Wire colour

1

–

Shield

-

2

+24 V DC

Operating voltage red

3

GND

Ground black

4

CAN H

CAN bus (IN/OUT)

white

5

CAN L

CAN bus (IN/OUT)

blue

Tab. 6-12:

8011975/0000/2008-04-14

Signal

Pin assignment of the 5-pole M12 plug and wire colours at the open end

© SICK AG · Division Auto Ident · Germany · All rights reserved

63

Page 64

Chapter 6

Electrical installation

Operating Instructions CLV640 Bar Code Scanner

Cable no. 6034418 (Standard version)

Pin (15-pole) Signal

Function

Wire colour

1

18 ... 30 V DC

Operating voltage red

2

RxD (Aux)

Aux interface (receiver)

violet

3

TxD (Aux)

Aux interface (sender)

yellow

4

Sensor 2

Digital switching input (adjustable function, e. g. external reading pulse)

red-black

5

GND

Ground black

6

RD+ (RS-422/485)

Host interface (receiver)

light blue

7

RD– (RS-422/485); RxD (RS-232)

Host interface (receiver)

blue

8

TD+ (RS-422/485)

Host interface (sender)

light grey-turquoise

9

TD– (RS-422/485); TxD (RS-232)

Host interface (sender)

green

10

CAN H

CAN bus (IN/OUT)

grey

11

CAN L

CAN bus (IN/OUT)

pink

12

Result 1

Digital switching output, adjustable brown function

13

Result 2

Digital switching output, adjustable orange function

14

Sensor 1

Digital switching input for external reading pulse white

15

SensGND

Common ground for the switching inputs white-black

Tab. 6-13:

64

Pin assignment of the 15-pole D-Sub-HD socket and wire colours at the open cable end

© SICK AG · Division Auto Ident · Germany · All rights reserved

8011975/0000/2008-04-14