Page 65

Operating Instructions

Startup and configuration

Chapter 7

CLV640 Bar Code Scanner

7

Startup and configuration Startup, adjustments, configuration and diagnosis are carried out via the SOPAS-ET configuration software. A simple reading rate diagnosis (integrated bargraph display) can, among other things, be called up independently via two buttons on the device. See chapter 4.7.3 Buttons on the bar code scanner housing, page 38.

7.1

Overview of the startup procedure

•

Start up the bar code scanner with the factory default settings

•

Install SOPAS-ET configuration software

•

Connect the PC with the SOPAS-ET configuration software to the bar code scanner

•

In order to optimise the functionality of the bar code scanner, if necessary, adjust and configure the bar code scanner

•

Check correct functioning of the bar code scanner in reading operation

7.2

SOPAS-ET configuration software

The SOPAS-ET configuration software optimises the bar code scanner to the reading conditions on site. The configuration data can be saved and archived as a parameter set (project file) on the PC. 7.2.1

Functions of the SOPAS-ET configuration software for the bar code scanner (overview)

The online help in the SOPAS-ET configuration software describes the general functions of the software and their operation: MENU, HELP, HELP F1 •

Selecting the menu language (English, German)

•

Setup communication with the bar code scanner

•

Password protected configuration for various operating levels

•

Recording of data during the current mode (recording and analyzing the data of certain bar code scanner memory areas via the data recorder)

•

Diagnosing the system

7.2.2

System requirements for the SOPAS-ET configuration software

PC system requirements: •

Recommendation: Pentium III, 500 MHz, 512 MB RAM, CD drive, RS-232 serial data interface or Ethernet interface card, mouse (recommended) and colour monitor (recommended resolution 1,024 x 768 pixels)

•

Operating system Windows 2000TM, Windows XPTM or Windows VistaTM

•

Free storage space on the hard drive: approx. 100 MB for SOPAS-ET (V. 2.14) configuration software with help files and approx. 70 MB for "Acrobat Reader"

•

PC HTML browser, e.g. Internet ExplorerTM: For online help system for the SOPAS-ET configuration software

Connection cables: See chapter 11.4.7 Accessories: Cables for Ethernet version, page 115 and chapter 11.4.8 Accessories: General cables and connectors, page 115.

8011975/0000/2008-04-14

© SICK AG · Division Auto Ident · Germany · All rights reserved

65

Page 66

Startup and configuration

Chapter 7

Operating Instructions CLV640 Bar Code Scanner

7.2.3

Installing the SOPAS-ET configuration software

1.

Start the PC and insert the installation CD.

2.

If installation does not start automatically, call setup.exe on the CD.

3.

Follow the operating instructions to conclude installation.

7.2.4

Default setting for SOPAS-ET configuration software

Parameter

Value

User interface language

English (the software has to be restarted after changes)

Units of length

Metric

User group (operating level)

Maintenance

Download parameter for changes

Immediate, temporary (bar code scanner's RAM)

Upload parameter after online switching

Automatic

Window layout

3 (project tree, help, work area)

Serial communication

COM 1: 9,600 Bd/19,200 Bd, 8 data bits, 1 stop bit, no parity 1)

Tab. 7-1:

7.3 Prerequisite

Establish communication with the bar code scanner

The TCP-IP protocol at the PC has to be active to enable communication via TCP-IP. 7.3.1 ¾

Connecting data interfaces

Connect the PC and bar code scanner to each other.

Connection

Via data interface

Bar code scanner

STANDARD (RS-232) Directly connect the PC (serial interface) to the AUX or HOST connection of the bar code scanner using a suitable cable (see chapter 11.4.8 Accessories: General cables and connectors, page 115).

Bar code scanner (optional)

ETHERNET (10/100 MBit/s)

Tab. 7-2:

66

Default setting for the SOPAS-ET configuration software (excerpt)

Comment

Directly connect the PC (Ethernet interface) to the ETHERNET connection of the bar code scanner (see chapter 11.4.7 Accessories: Cables for Ethernet version, page 115).

Connection between the PC with SOPAS-ET configuration software and the bar code scanner

© SICK AG · Division Auto Ident · Germany · All rights reserved

8011975/0000/2008-04-14

Page 67

Startup and configuration

Operating Instructions

Chapter 7

CLV640 Bar Code Scanner

7.3.2 1.

Starting the SOPAS-ET configuration software and calling the scan assistant

Switch the power supply to the bar code scanner on. The bar code scanner performs a self-test and is initialised.

2.

Switch on the PC and start the SOPAS-ET configuration software. The SOPAS-ET configuration software opens the program window with an English program interface as standard.

3.

In order to change the language setting, click on CANCEL and change the language of the program interface to e. g. GERMAN/DEUTSCH via the menu TOOLS/OPTIONS.

4.

Once the language setting has been changed, shut down the SOPAS-ET configuration software and restart it.

5.

In the dialog window, select the option CREATE A NEW PROJECT and click on OK to confirm it.

6.

In the main window under SCAN ASSISTENT click on the CONFIGURATION button. The dialog window SCAN WIZARD appears.

7.3.3 TIP

Configuring the Ethernet connection

To establish a connection quickly and easily via Ethernet, the SOPAS-ET configuration software has a CONNECTION WIZARD in the TOOLS menu. Manual configuration: 1.

In the dialog window NETWORK SCAN WIZARD under INTERNET PROTOCOL/INTERNET PROTOCOL (IP), check the check box for ENABLE IP COMMUNICATION.

2.

Click on the ADD button.

3.

Enter the IP address of the bar code scanner and confirm it by pressing OK in the dialog window. The dialog window closes. A new entry appears in the IP ADDRESS CONFIGURATION list.

4.

Click on OK to confirm settings. The dialog window ADVANCED SCAN SETTINGS closes.

7.3.4

Configuring the serial connection

1.

In the dialog window NETWORK SCAN WIZARD under SERIAL PORT/STANDARD PROTOCOL, check the check box for ENABLE SERIAL COMMUNICATION.

2.

Click on the ADVANCED... button.

3.

Under SELECT BAUDRATE(S) deactivate all the baud rates except 57.6 KBD.

4.

Select the following PORT SETTINGS: 8 data bits, no parity, 1 stop bit.

5.

Click on OK to confirm settings. The dialog window ADVANCED SCAN SETTINGS closes.

7.3.5

Carrying out a scan

1.

In the dialog window SCAN ASSISTENT click on the NETWORK SCAN button.

2.

Select the listed devices (CLV640) and confirm via ADD DEVICE. Connected devices are searched for via the connection. The SOPAS-ET configuration software inserts the found device in the project tree and uploads the current parameter set (SYNC CHECK).

3.

8011975/0000/2008-04-14

For configuration of the devices see chapter 7.4.2 Configuring the bar code scanner, page 69.

© SICK AG · Division Auto Ident · Germany · All rights reserved

67

Page 68

Chapter 7

Startup and configuration

Operating Instructions CLV640 Bar Code Scanner

7.4

First startup

The SOPAS-ET configuration software optimises the bar code scanner to the reading conditions on site. Starting point for this is the factory default setting which can be adjusted to optimise the bar code scanner. The SOPAS-ET configuration software is used to create an application-specific parameter set which can be loaded permanently into the bar code scanner and saved/archived as a project file (spr file with configuration data) on the PC.

Fig. 7-1:

Configuration with SOPAS-ET and storage the parameter set

If the bar code scanner is optionally connected to a Micro SD memory card (see chapter 4.7.4 Parameter set on the Micro SD memory card (optional), page 40) or connected to a module with parameter memory mode CMC600, the parameter set is saved permanently to the memory card, or to the CMC600 repectively, with every permanent storage of the parameter set to the bar code scanner. After the bar code scanner is restarted, the data from the memors card, repectively from the CMC600 is automatically transferred to the bar code scanner. As such, a bar code scanner can be exchanged, for example, without losing configuration data (see chapter 8.5 Replacing a bar code scanner, page 76). If there is a memory card as well as a CMC600, the bar code scanner takes the parameter set from the CMC600. 7.4.1

68

Overview of the startup procedure

•

Connect data interfaces of the PC and the bar code scanner

•

Start the SOPAS-ET configuration software and create a new project file

•

Configure the scan assistant (activate PC communication)

•

Establish communication with the bar code scanner

•

Accept current configuration of the bar code scanner in the project tree

•

Log on as an "Authorized client" to the bar code scanner

•

Configure the bar code scanner for use

•

If necessary, apply the "Event Monitor" diagnosis tool

•

Load the optimised configuration into the bar code scanner and save permanently

•

Save the project file with the configuration data of the bar code scanner on the PC

© SICK AG · Division Auto Ident · Germany · All rights reserved

8011975/0000/2008-04-14

Page 69

Startup and configuration

Operating Instructions

Chapter 7

CLV640 Bar Code Scanner

7.4.2

Configuring the bar code scanner

All configurable parameters for the bar code scanner are grouped into a device description (jar-file) for the SOPAS-ET configuration software. The device description's project tree acts as a guideline for the configuration. The function of each respective parameter is explained in a context-sensitive manner in an online help (F1 key). The valid value range and the default setting list the display window PARAMETER INFO (right mouse button, when the cursor is positioned over the parameter). Note

In order to configure a device via the SOPAS-ET configuration software, the respective operating level has to be selected in advance. After the start, the SOPAS-ET configuration software functions at the operating level "MAINTENANCE".

1.

In the menu bar under TOOLS select the command LOGIN DEVICE.

2.

In the dialog window under USERLEVEL in the list box select the entry AUTHORIZED CLIENT. If the parameter set is password-protected, enter the password "client" in PASSWORD. Activate/deactivate password protection on the PARAMETER register tab.

3.

Click on OK to confirm the dialog window. The previously greyed out parameters on the register tabs are now accessible.

7.4.3

Permanently load changed parameter sets into the device

Changed parameter values are immediately transferred to the bar code scanner's main memory (RAM) depending on the option (“Immediate download“). To ensure that the changes remain even after the bar code scanner is restarted, the configuration has to be permanently saved in the bar code scanner's PROM. ¾

In order to load the current settings permanently in the bar code scanner, select the command PARAMETER/SAVE PERMANENT in the menu bar under CLV640 or click on in the tool bar.

7.4.4

Save, display and print the current parameter set

When archiving a parameter set it is recommended to not only save the project file on the PC but also print out the contents of the file. 1.

In order to save the current parameter set, select the menu item SAVE PROJECT AS in the menu bar under PROJECT.

2.

Enter a file name in the dialog window and confirm it via SAVE. The SOPAS-ET configuration software saves the current settings in a configuration file “*.SPR“.

3.

In order to print out the current parameter set, select the command PRINT/PRINT PREVIEW in the menu bar under PROJECT. The SOPAS-ET configuration software displays a preview of a table with a list of all the parameter values.

4.

Click on in the tool bar at the top of the dialog window.

The dialog window PRINT for the printer configuration appears. 5.

Edit setting accordingly and confirm with OK. The current project settings are printed as a table on several pages.

TIP

8011975/0000/2008-04-14

To save the current parameter set as a PDF, in the menu bar under PROJECT select the command PRINT/SAVE AS PDF FILE.

© SICK AG · Division Auto Ident · Germany · All rights reserved

69

Page 70

Startup and configuration

Chapter 7

Operating Instructions CLV640 Bar Code Scanner

7.5

Default setting

The values of the default setting are permanently saved in the bar code scanner (ROM) and in the database of the SOPAS-ET configuration software in the device-specific jar file (see chapter 7.4 First startup, page 68). A PC is not required to start up the bar code scanner with the default setting. 7.5.1 Prerequisite

Resetting the default setting in the bar code scanner

The SOPAS-ET configuration software is connected online to the bar code scanner. Two default setting types can be called up via the SOPAS-ET configuration software: •

Complete default setting (LOAD FACTORY DEFAULT) SOPAS-ET resets all parameter values of the bar code scanner to default. Settings which have been previously made for the communication parameters of the Ethernet interfaces or serial data interfaces (e.g. Ethernet address) are overwritten. The connection(s) to the bar code scanner might be interrupted and has (have) to be reconfigured.

•

Application-specific default setting (LOAD APPLICATION DEFAULT) SOPAS-ET resets the parameter values of the bar code scanner but does not change the communication parameters. Settings which have been previously made for the communication parameters of the Ethernet interfaces or serial data interfaces are kept and the current connection(s) to the bar code scanner remain(s) established.

1.

In order to discard changes to the parameter set as described above, select the corresponding command in the menu bar under CLV640. The SOPAS-ET configuration software loads the default setting from the bar code scanner and displays the parameter values in the register tabs. In the bar code scanner, the default setting will first be active in the temporary main memory only. The default setting can also be saved on or printed via the PC, chapter 7.4.4 Save, display and print the current parameter set, page 69.

2.

In the menu bar under TOOLS select the command LOGIN DEVICE.

3.

In the dialog window under USERLEVEL in the list box select the entry AUTORIZED CLIENT.

4.

Click on OK to confirm the dialog window.

5.

In the menu bar under CLV640 select the command PARAMETER/SAVE PERMANENT.

If the parameter set is password-protected, enter the password "client" in PASSWORD.

The SOPAS-ET configuration software transfers the default setting to the permanent parameter memory (PROM) of the bar code scanner. If the bar code scanner is equiped with the Micro SD memory card or connected to a connection module CDB620/CDM420 with parameter memory module CMC600, the default setting will be permanently transferred to parameter memory CMC600 or memory card respectively. Important

70

Once the default setting has been restored, password-protection is deactivated.

© SICK AG · Division Auto Ident · Germany · All rights reserved

8011975/0000/2008-04-14

Page 71

Operating Instructions

Startup and configuration

Chapter 7

CLV640 Bar Code Scanner

7.6

Adjusting the bar code scanner

7.6.1

Adjusting the bar code scanner

To completely adjust the bar code scanner, the electrical installation must be complete and the device must be operated, see chapter 6 Electrical installation, page 51 and chapter 7 Startup and configuration, page 65. 1.

Align the bar code scanner in such a way that the angle between the scanning line and the bar code's lines is almost 90°.

2.

To avoid disruptive reflections, rotate the bar code scanner from the plumb line so that the emitting light meets the bar code at an angle of approx. 105° (line scanner), chapter 5.3.4 Avoiding surface reflections, page 46.

3.

Manually bring objects with bar codes sequentially into the bar code scanner's visual range. The default setting of the focal position is 285 mm (11.2 in) from the reading window. Check the reading result using the SOPAS-ET configuration software. Move objects in different positions (angles) to the reading area and ensure that the thresholds of the permitted reading angles are not exceeded.

4.

Align the bar code scanner in such a way that the good read rate is between 70 and 100%.

5.

Tighten the screws on the bar code scanner. The bar code scanner is aligned with the bar code.

8011975/0000/2008-04-14

© SICK AG · Division Auto Ident · Germany · All rights reserved

71

Page 72

Chapter 7

Startup and configuration

Operating Instructions CLV640 Bar Code Scanner

72

© SICK AG · Division Auto Ident · Germany · All rights reserved

8011975/0000/2008-04-14