Page 73
Operating Instructions
Maintenance
Chapter 8
CLV640 Bar Code Scanner
8
Maintenance 8.1
Maintenance during operation
The bar code scanner functions maintenance free. Maintenance is not required to ensure compliance with the bar code scanner's laser class 2. Important
Do not open the bar code scanner's housing. If the device is opened, the SICK AG warranty shall not apply.
8.2 Recommendation
Cleaning the bar code scanner
In order to make use of the full optical reading capacity of the bar code scanner, the reading window should be checked regularly (e. g. weekly) for soiling. This is especially recommended when operating the device in harsh conditions (dust, abrasion, humidity, finger prints, etc.).
Damage to the eyes through laser radiation! The bar code scanner works with an red light laser of class 2. Looking at the laser's light path for a longer period of time can damage the eye's retina. The entire reading window is the LED radiation outlet opening. Caution - use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiaton exposure. ¾
Never look directly into the light path (similar to sun light).
¾
Never direct the device's laser beam at the eyes of persons.
¾
When installing and aligning the bar code scanner, avoid laser beam reflections from reflective surfaces.
¾
Do not open the housing. (Opening does not interrupt the activation of the laser diode by the reading pulsing.)
¾
Always observe the latest valid version of laser protection regulations.
The type place displays the window material used for the reading window: CLV640-xxxy
8011975/0000/2008-04-14
• y = 0: Glass
• y = 1: Plastic
© SICK AG · Division Auto Ident · Germany · All rights reserved
73
Page 74
Maintenance
Chapter 8
Operating Instructions CLV640 Bar Code Scanner
8.2.1
Cleaning the reading window
Damage to the reading window! Reduced reading capacity due to scratches or smears on the reading window! The reading window for versions CLV640-xxx0 is made of glass. ¾
Do not use aggressive cleaning agents.
¾
Do not use cleaning agents which cause increased abrasion (e.g. powder).
¾
Avoid cleaning motions on the reading window which could cause scratches or abrasion.
Damage to the reading window! Reduced reading capacity due to scratches or smears on the reading window! The reading window for versions CLV640-xxx1 is made of plastic.
Important
74
¾
Only clean the reading window with a damp cloth.
¾
Use mild cleansing agents without powder. Do not use strong cleansing agents such as acetone.
¾
Avoid cleaning motions on the reading window which could cause scratches or abrasion.
Electrostatic charges cause dust particles to stick to the reading window. This effect can be combated by using anti-static SICK synthetic cleaner (no. 5600006) in combination with a SICK lens cloth (no. 4003353).
© SICK AG · Division Auto Ident · Germany · All rights reserved
8011975/0000/2008-04-14
Page 75
Operating Instructions
Maintenance
Chapter 8
CLV640 Bar Code Scanner
Cleaning the reading window:
Fig. 8-1:
¾
Switch off the device while you are cleaning it (see Laser protection).
¾
Use a clean, soft brush to free the (glass) reading window from dust.
¾
If necessary, additionally clean the (glass) reading window with a clean, damp, lint-free cloth and a mild, anti-static window cleaning fluid.
¾
Only clean the (plastic) reading window with a clean, damp, lint-free cloth and a mild, anti-static window cleaning fluid.
Cleaning the reading window
If the reading window is scratched or damaged (cracked, broken), it must be replaced. Please contact the SICK Service. 8.2.2
8011975/0000/2008-04-14
Cleaning the housing
¾
Use a soft cloth to free the housing of dust.
¾
If necessary, also clean the LEDs on the housing.
© SICK AG · Division Auto Ident · Germany · All rights reserved
75
Page 76
Maintenance
Chapter 8
Operating Instructions CLV640 Bar Code Scanner
8.3
Cleaning further optical effective surfaces
Depending on the reading system equipment, additional external sensors with optical effective surfaces can be installed (e.g. photoelectric reflex switch for external reading pulsing). Soiling of these sensors can cause incorrect switching behaviour. ¾
In order to prevent incorrect switching behaviour, remove soiling from the optical effective surfaces of the external sensors.
Fig. 8-2:
8.4
Cleaning of the external optical sensors (reading pulse generator)
Checking the incremental encoder
If an optional incremental encoder is used, the position of the friction wheel at the drive system should be checked at regular intervals. ¾
Ensure that the incremental encoder has direct and fixed contact with the drive system and that the friction wheel rotates without slipping.
8.5
Replacing a bar code scanner
Incorrect or damaged bar code scanners have to be removed and replaced with either new or repaired bar code scanners. Important
Repairs to the bar code scanner should only be carried out by qualified and authorised SICK AG service staff. 8.5.1 1.
76
Removing the bar code scanner
Switch the power supply to the bar code scanner off.
2.
Disconnect all the connection cables on the bar code scanner.
3.
Remove the bar code scanner from the holder. Mark the bar code scanner's situation and alignment on the holder or environment.
4.
If available, remove the Micro SD memory card (optional) with the stored parameter set from the faulty bar code scanner (see chapter 4.7.4 Parameter set on the Micro SD memory card (optional), page 40). To do this, carefully open the black rubber cover and slightly press on the memory card in order to unlock it.
5.
Insert the memory card accordingly into the empty space of the new, turned-off bar code scanner the right way round (contacts to the back and top) until it is locked.
6.
Close the rubber cover.
© SICK AG · Division Auto Ident · Germany · All rights reserved
8011975/0000/2008-04-14
Page 77
Operating Instructions
Maintenance
Chapter 8
CLV640 Bar Code Scanner
8.5.2
Replacing the bar code scanner
1.
Align and install the new or repaired bar code scanner (see chapter 5 Installation, page 41). Observe any marks made previously on the holder or the environment (chapter 8.5.1 Removing the bar code scanner, page 76).
2.
Reconnect connection cables to the bar code scanner (see chapter 6 Electrical installation, page 51).
3.
Switch the power supply to the bar code scanner back on. The bar code scanner starts with the default setting.
4.
If, as an option, a Micro SD memory card has been inserted into the bar code scanner or a parameter memory module CMC600 into connection module CDB620/CDM420, the new bar code scanner will automatically load the stored parameter set from the memory card or CMC600 into its permanent memory. If both a memory card and a CMC600 are available, the bar code scanner will load the parameter set from the CMC600. - or Without Micro SD memory card /parameter memory module CMC600: Connect to the bar code scanner via the SOPAS-ET configuration software, transfer the configuration stored on the PC via download to the bar code scanner and permanently store the configuration there.
8011975/0000/2008-04-14
© SICK AG · Division Auto Ident · Germany · All rights reserved
77
Page 78
Chapter 8
Maintenance
Operating Instructions CLV640 Bar Code Scanner
78
© SICK AG · Division Auto Ident · Germany · All rights reserved
8011975/0000/2008-04-14