Page 79
Operating Instructions
Troubleshooting
Chapter 9
CLV640 Bar Code Scanner
9
Troubleshooting This chapter describes how errors at the bar code scanner can be recognised and eliminated.
9.1
Overview of errors and malfunctions which could occur
9.1.1
Installation error
•
The bar code scanner has been unsuitably aligned to objects with bar codes (e.g. visual glare)
•
Reading pulse sensor has been incorrectly positioned (e.g. internal reading gate opens too late or shuts too early)
•
Incremental encoder (optional) positioned incorrectly
9.1.2 •
Electrical installation error
Interfaces of the bar code scanner wired incorrectly
9.1.3
Configuration error
•
Functions have not been adjusted to the local conditions, e.g. parameters for the data interface set incorrectly
•
Device-related limits have not been considered, e.g. reading distance, aperture angle
•
Selected trigger source for reading pulse incorrect
9.1.4
Malfunctions during operation
•
Start/Stop operation: External reading pulse is missing, more than one object is in the reading area
•
Device error (hardware/software)
9.2
Detailed malfunction analysis
9.2.1
LEDs on the bar code scanner
The following statuses can, among other things, be read from the LEDs on the bar code scanner's housing (see chapter 4.7.2 LEDs on the bar code scanner's housing, page 37): •
Reading reliability (Bar graph, diagnostic mode)
•
Ready
•
Status of the reading result (Result)
•
Data trafic on the Host-, Aux- and CAN-interface
The LEDs can display possible malfunctions or errors. Please refer to the system information for further details.
8011975/0000/2008-04-14
© SICK AG · Division Auto Ident · Germany · All rights reserved
79
Page 80
Troubleshooting
Chapter 9
Operating Instructions CLV640 Bar Code Scanner
9.2.2
System information
The bar code scanner displays errors in various ways. The error output is hierarchised and always allows a detailed analysis: •
Communication errors can occur while transferring telegrams to the bar code scanner. In this case, the bar code scanner returns an error code.
•
Error codes are written into a status protocol for errors which occur during a reading (chapter 9.3 Status protocol, page 80).
9.3 Important
Status protocol
The status protocol remains even after switching the bar code scanner off and on again. The bar code scanner differentiates between four error types: •
Information
•
Warning
•
Error
•
Fatal error
The bar code scanner only saves the last five entries for each of the error types. 9.3.1
Displaying the status protocol using the SOPAS-ET configuration software
In order to display the status protocol, the SOPAS-ET configuration software has to be online and connected to the bar code scanner. 1.
Connect the SOPAS-ET configuration software with the device.
2.
Open the project tree CLV640, SERVICE, SYSTEMSTATUS, register tab SYSTEMINFORMATION.
9.4
SICK Support
If an error cannot be eliminated, it is possible that the bar code scanner is defective. The bar code scanner cannot be repaired by the user, meaning that it is not possible to re-establish functions after a failure. However, the bar code scanner can be rapidly replaced by the user. See chapter 8.5 Replacing a bar code scanner, page 76. ¾
If an error occurs which cannot be eliminated, please contact SICK Service:
•
International: Competent SICK branch office or SICK subsidiary – Telephone numbers and e-mail addresses on the reverse side of these operating instructions – For the postal address please visit www.sick.com
¾ Important
80
Only return devices after consultation with the SICK Service.
Repairs to the bar code scanner should only be performed by qualified and authorised SICK AG service staff.
© SICK AG · Division Auto Ident · Germany · All rights reserved
8011975/0000/2008-04-14
Page 81
Operating Instructions
Technical data
Chapter 10
CLV640 Bar Code Scanner
10
Technical data 10.1
Datenblatt Barcodescanner CLV640 (Linien-/ Rasterscanner)
Type
CLV640 Bar Code Scanner
Focus
Dynamic focus position
Reading window
Line / Raster scanner: With front/side reading window (with angle attachment: light entrance/exit under 105°)
Laser diode (wavelength)
Red light (λ = 655 nm)
MTTR of the laser diode
20,000 h
Device laser class
Class 2 in accordance with IEC 60825-1 and EN 60825-1, see warning sign on device for date of publication
Useable aperture angle max. 50° (front reading window and side reading window)
Scan/decoder frequency
400 ... 1,200 Hz
Resolution
0,20 ... 1.0 mm (5.9 ... 39.5 mil) (type-dependent)
Raster height
15 mm (0.6 in) (8 lines) with 200 mm (7.9 in) reading distance (front reading window)
Bar code print contrast (PCS)
≥ 60 %
Ambient light compatibility
2,000 lx (on bar code)
Number of bar codes per scan
1 ... 20 standard decoder; 1 ... 6 SMART decoder
Number of bar codes per reading 1 ... 50 bar codes (auto-discriminating) gate1) Bar code types
Code 39, Code 128, Code 93, Codabar, EAN, EAN 128, UPC, 2/5 Interleaved, Pharmacode
Bar code lengths
Max. 50 characters (max. 5,000 characters across all bar codes per reading gate, 500 characters with multiplexer function (CAN))
Print ratio
2:1 ... 3:1
Number of multireads
1 ... 99
Memory card for parameters (cloning)
Micro SD card (flash card) 512 MB, optional
Optical indicators
6 LEDs: Ready, Result, Laser, Data, CAN, LNK TX and bargraph display
Acoustic display
Beeper, can be switched off, with function for result status display
Control elements
2 buttons (selecting and starting/stopping functions)
Reading pulsing
Pulse sources for start: Switching inputs "Sensor 1"2) and/or "Sensor 2"; command; Automatic Cycle; CAN Pulse sources for stop: Reading pulse source, "Sensor 1", "Sensor 2", command, timer, good read, condition
"Host" data interface
Serial: RS-232 or RS-422/485; Ethernet (port 2112), adjustable data format (serial) and data output format
Data transfer rate
2,4 ... 115.2 kbd
Protocols
SICK standard (SOPAS-Cola-A)
Physical configurations
Stand-alone
"Aux" data interface
Serial: RS-232 (57.6 kbd; 8 data bits, no parity, 1 stop bit); Ethernet (port 2111); fixed data output format
"Ethernet" data interface
Only for Ethernet version: 10/100 MBit/s, TCP/IP, half/full duplex
"CAN" data interface
20 kBit/s ... 1 MBit/s, SICK CAN-SENSOR network (Master, Slave, Multiplexer)
Digital switching inputs
Standard version: 2 ("Sensor 1", "Sensor 2"), 2 additional inputs via CMC600 in CDB620 Ethernet version: 1 ("Sensor 1"), 2 additional inputs via CMC600 in CDB620, optodecoupled, Vin = max. 32 V, reverse polarity protected, can be wired with PNP output, configurable debouncing 0 ...10.000 ms
8011975/0000/2008-04-14
© SICK AG · Division Auto Ident · Germany · All rights reserved
81
Page 82
Technical data
Chapter 10
Operating Instructions CLV640 Bar Code Scanner
Type
CLV640 Bar Code Scanner
Digital switching outputs
Standard version: 2 ("Result 1", "Result 2"), 2 additional outputs via CMC600 in CDB620 Ethernet version: no output, 2 outputs via CMC600 in CDB620 PNP, Iout = max. 100 mA, short circuit-proof, configurable impulse duration (static, 10 ... 1.000 ms)
Electrical connection
Standard version: Cable (0.9 m (3 ft)) with 15-pole D-Sub-HD plug Ethernet version: Revolving connector unit with two M12 circular connectors (12-pole plug, 4-pole socket)
Operating voltage
18 ... 30 V DC in accordance with IEC 364-4-41 (SELV respectively PELV acc. to IEC 60364-4-41 (2005))
Current consumption
Line / Raster scanner: typically 5.5 W with DC 24 V ± 10%
Housing
Die-cast aluminium
Reading window material
Glass or plastic, see type plate CLV640-xxxy (y = 0: glass, y = 1: plastic)
Electrical safety according to EN 60950-1 (2006-04)
Safety class
III, according to EN 61140 (2002-03)
Enclosure rating
IP 65, according to EN 60529 (1991-10); A1 (2002-02)
EMC test
Emission: according to EN 61000-6-3 (2001-10); immunity: according to EN 61000-6-2 (2005-08)
Vibration-/ shock-test according to EN 60068-2-6 (1995) / according to EN 60068-2-27 (1993)
Weight
Standard version: 320 g with connection cable (front reading window), 340 g (side reading window) Ethernet version: 250 g without connection cables (front reading window), 270 g (side reading window)
Ambient operating temperature/ 0 ... +40 °C/–20 ... +70 °C storage temperature Max. rel. humidity
90%, no condensation
Housing colour
SICK Blue (light blue according to RAL 5012)
1) Reading gate: code evaluation time window created internally by the reading pulse 2) Ethernet version: only switching input "Sensor 1"
Tab. 10-1:
82
Technical specifications for the CLV640 Bar Code Scanner (line/raster scanner)
© SICK AG · Division Auto Ident · Germany · All rights reserved
8011975/0000/2008-04-14
Page 83
Operating Instructions
Technical data
Chapter 10
CLV640 Bar Code Scanner
10.2
Data sheet for the CLV640 Bar Code Scanner (line scanner with oscillating mirror)
The technical specifications correspond to those of the CLV640 Bar Code Scanner (line/raster scanner), except for the following variations: Type
CLV640 Bar Code Scanner
Reading window side reading window, light exit under 105° (default setting)
Useable aperture angle max. 50°
Oscillating mirror functions
Uncontrolled operation: • Fixed (position can be adjusted) or • Continuous, free oscillation Controlled operation (start/stop condition can be adjusted): • Triggered oscillation (start position and number of oscillations can be adjusted) • One-shot: One-time oscillation in forward and return motion (start position can be adjusted) In every oscillation mode, the amplitude can be adjusted separately for each of the two deflection directions. The deflection speed ratio of one deflection direction to the other can be adjusted within the selected periodic time for a complete oscillation sequence.
Oscillation frequency / Periodic time
0.5 ... 6.25 Hz / 2,000 ... 160 ms
Max. angle of deflection (amplitude)
+20° ... –20°
Current consumption
Typically 6.5 W with DC 24 V ±10 %
Weight
Standard version: 420 g Ethernet version: 350 g
Tab. 10-2:
Technical specifications for the CLV640 Bar Code Scanner (line scanner with oscillating mirror)
8011975/0000/2008-04-14
© SICK AG · Division Auto Ident · Germany · All rights reserved
83
Page 84
Chapter 10
Technical data
Operating Instructions CLV640 Bar Code Scanner
10.3 Test code
Code 39/ITF
Print ratio
2:1
Print contrast
> 90 %
Tilt
±10°
Ambient light
< 2 000 lx
Good read rate
> 75 %
Tab. 10-3:
Fig. 10-1:
Specification diagrams
Reading conditions for all specification diagrams
Meaning of selection 1, 2 and 3 in the reading area diagram related to depth of focus diagram.
Observing the reading area diagram (see figure) of the CLV640 of a module width at a focal position from the top, the selections 1, 2 and 3 can be transferred to the depth of focus diagram for this module width as follows. Therefore, the depth of focus diagram consists of a slice-shaped sequence of many reading area diagrams along the focal position.
84
© SICK AG · Division Auto Ident · Germany · All rights reserved
8011975/0000/2008-04-14
Page 85
Operating Instructions
Technical data
Chapter 10
CLV640 Bar Code Scanner
10.3.1
Fig. 10-2:
Depth of field ranges of the line scanner/raster scanner with front reading window
Line scanner/raster scanner with front reading window: min. and max. reading distance depending on the focus position and the aperture angle with a resolution of 0.2 mm (8 mil)
8011975/0000/2008-04-14
© SICK AG · Division Auto Ident · Germany · All rights reserved
85
Page 86
Chapter 10
Technical data
Operating Instructions CLV640 Bar Code Scanner
Fig. 10-3:
86
Line scanner/raster scanner with front reading window: min. and max. reading distance depending on the focus position and the aperture angle with a resolution of 0.25 mm (10 mil)
© SICK AG · Division Auto Ident · Germany · All rights reserved
8011975/0000/2008-04-14
Page 87
Operating Instructions
Technical data
Chapter 10
CLV640 Bar Code Scanner
Fig. 10-4:
Line scanner/raster scanner with front reading window: min. and max. reading distance depending on the focus position and the aperture angle with a resolution of 0.35 mm (14 mil)
8011975/0000/2008-04-14
© SICK AG · Division Auto Ident · Germany · All rights reserved
87
Page 88
Chapter 10
Technical data
Operating Instructions CLV640 Bar Code Scanner
Fig. 10-5:
88
Line scanner/raster scanner with front reading window: min. and max. reading distance depending on the focus position and the aperture angle with a resolution of 0.5 mm (20 mil)
© SICK AG · Division Auto Ident · Germany · All rights reserved
8011975/0000/2008-04-14