Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 10 of 15

Operating Instructions: CLV640 Bar Code Scanner, Advanced Line, pages 79 to 88

Pages 79 to 88 of 132: 9 Troubleshooting; 10 Technical data

The original document is the PDF (7.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Sick CLV640

Page 79

Operating Instructions

Troubleshooting

Chapter 9

CLV640 Bar Code Scanner

9

Troubleshooting This chapter describes how errors at the bar code scanner can be recognised and eliminated.

9.1

Overview of errors and malfunctions which could occur

9.1.1

Installation error

•

The bar code scanner has been unsuitably aligned to objects with bar codes (e.g. visual glare)

•

Reading pulse sensor has been incorrectly positioned (e.g. internal reading gate opens too late or shuts too early)

•

Incremental encoder (optional) positioned incorrectly

9.1.2 •

Electrical installation error

Interfaces of the bar code scanner wired incorrectly

9.1.3

Configuration error

•

Functions have not been adjusted to the local conditions, e.g. parameters for the data interface set incorrectly

•

Device-related limits have not been considered, e.g. reading distance, aperture angle

•

Selected trigger source for reading pulse incorrect

9.1.4

Malfunctions during operation

•

Start/Stop operation: External reading pulse is missing, more than one object is in the reading area

•

Device error (hardware/software)

9.2

Detailed malfunction analysis

9.2.1

LEDs on the bar code scanner

The following statuses can, among other things, be read from the LEDs on the bar code scanner's housing (see chapter 4.7.2 LEDs on the bar code scanner's housing, page 37): •

Reading reliability (Bar graph, diagnostic mode)

•

Ready

•

Status of the reading result (Result)

•

Data trafic on the Host-, Aux- and CAN-interface

The LEDs can display possible malfunctions or errors. Please refer to the system information for further details.

8011975/0000/2008-04-14

© SICK AG · Division Auto Ident · Germany · All rights reserved

79

Page 80

Troubleshooting

Chapter 9

Operating Instructions CLV640 Bar Code Scanner

9.2.2

System information

The bar code scanner displays errors in various ways. The error output is hierarchised and always allows a detailed analysis: •

Communication errors can occur while transferring telegrams to the bar code scanner. In this case, the bar code scanner returns an error code.

•

Error codes are written into a status protocol for errors which occur during a reading (chapter 9.3 Status protocol, page 80).

9.3 Important

Status protocol

The status protocol remains even after switching the bar code scanner off and on again. The bar code scanner differentiates between four error types: •

Information

•

Warning

•

Error

•

Fatal error

The bar code scanner only saves the last five entries for each of the error types. 9.3.1

Displaying the status protocol using the SOPAS-ET configuration software

In order to display the status protocol, the SOPAS-ET configuration software has to be online and connected to the bar code scanner. 1.

Connect the SOPAS-ET configuration software with the device.

2.

Open the project tree CLV640, SERVICE, SYSTEMSTATUS, register tab SYSTEMINFORMATION.

9.4

SICK Support

If an error cannot be eliminated, it is possible that the bar code scanner is defective. The bar code scanner cannot be repaired by the user, meaning that it is not possible to re-establish functions after a failure. However, the bar code scanner can be rapidly replaced by the user. See chapter 8.5 Replacing a bar code scanner, page 76. ¾

If an error occurs which cannot be eliminated, please contact SICK Service:

•

International: Competent SICK branch office or SICK subsidiary – Telephone numbers and e-mail addresses on the reverse side of these operating instructions – For the postal address please visit www.sick.com

¾ Important

80

Only return devices after consultation with the SICK Service.

Repairs to the bar code scanner should only be performed by qualified and authorised SICK AG service staff.

© SICK AG · Division Auto Ident · Germany · All rights reserved

8011975/0000/2008-04-14

Page 81

Operating Instructions

Technical data

Chapter 10

CLV640 Bar Code Scanner

10

Technical data 10.1

Datenblatt Barcodescanner CLV640 (Linien-/ Rasterscanner)

Type

CLV640 Bar Code Scanner

Focus

Dynamic focus position

Reading window

Line / Raster scanner: With front/side reading window (with angle attachment: light entrance/exit under 105°)

Laser diode (wavelength)

Red light (λ = 655 nm)

MTTR of the laser diode

20,000 h

Device laser class

Class 2 in accordance with IEC 60825-1 and EN 60825-1, see warning sign on device for date of publication

Useable aperture angle max. 50° (front reading window and side reading window)

Scan/decoder frequency

400 ... 1,200 Hz

Resolution

0,20 ... 1.0 mm (5.9 ... 39.5 mil) (type-dependent)

Raster height

15 mm (0.6 in) (8 lines) with 200 mm (7.9 in) reading distance (front reading window)

Bar code print contrast (PCS)

≥ 60 %

Ambient light compatibility

2,000 lx (on bar code)

Number of bar codes per scan

1 ... 20 standard decoder; 1 ... 6 SMART decoder

Number of bar codes per reading 1 ... 50 bar codes (auto-discriminating) gate1) Bar code types

Code 39, Code 128, Code 93, Codabar, EAN, EAN 128, UPC, 2/5 Interleaved, Pharmacode

Bar code lengths

Max. 50 characters (max. 5,000 characters across all bar codes per reading gate, 500 characters with multiplexer function (CAN))

Print ratio

2:1 ... 3:1

Number of multireads

1 ... 99

Memory card for parameters (cloning)

Micro SD card (flash card) 512 MB, optional

Optical indicators

6 LEDs: Ready, Result, Laser, Data, CAN, LNK TX and bargraph display

Acoustic display

Beeper, can be switched off, with function for result status display

Control elements

2 buttons (selecting and starting/stopping functions)

Reading pulsing

Pulse sources for start: Switching inputs "Sensor 1"2) and/or "Sensor 2"; command; Automatic Cycle; CAN Pulse sources for stop: Reading pulse source, "Sensor 1", "Sensor 2", command, timer, good read, condition

"Host" data interface

Serial: RS-232 or RS-422/485; Ethernet (port 2112), adjustable data format (serial) and data output format

Data transfer rate

2,4 ... 115.2 kbd

Protocols

SICK standard (SOPAS-Cola-A)

Physical configurations

Stand-alone

"Aux" data interface

Serial: RS-232 (57.6 kbd; 8 data bits, no parity, 1 stop bit); Ethernet (port 2111); fixed data output format

"Ethernet" data interface

Only for Ethernet version: 10/100 MBit/s, TCP/IP, half/full duplex

"CAN" data interface

20 kBit/s ... 1 MBit/s, SICK CAN-SENSOR network (Master, Slave, Multiplexer)

Digital switching inputs

Standard version: 2 ("Sensor 1", "Sensor 2"), 2 additional inputs via CMC600 in CDB620 Ethernet version: 1 ("Sensor 1"), 2 additional inputs via CMC600 in CDB620, optodecoupled, Vin = max. 32 V, reverse polarity protected, can be wired with PNP output, configurable debouncing 0 ...10.000 ms

8011975/0000/2008-04-14

© SICK AG · Division Auto Ident · Germany · All rights reserved

81

Page 82

Technical data

Chapter 10

Operating Instructions CLV640 Bar Code Scanner

Type

CLV640 Bar Code Scanner

Digital switching outputs

Standard version: 2 ("Result 1", "Result 2"), 2 additional outputs via CMC600 in CDB620 Ethernet version: no output, 2 outputs via CMC600 in CDB620 PNP, Iout = max. 100 mA, short circuit-proof, configurable impulse duration (static, 10 ... 1.000 ms)

Electrical connection

Standard version: Cable (0.9 m (3 ft)) with 15-pole D-Sub-HD plug Ethernet version: Revolving connector unit with two M12 circular connectors (12-pole plug, 4-pole socket)

Operating voltage

18 ... 30 V DC in accordance with IEC 364-4-41 (SELV respectively PELV acc. to IEC 60364-4-41 (2005))

Current consumption

Line / Raster scanner: typically 5.5 W with DC 24 V ± 10%

Housing

Die-cast aluminium

Reading window material

Glass or plastic, see type plate CLV640-xxxy (y = 0: glass, y = 1: plastic)

Electrical safety according to EN 60950-1 (2006-04)

Safety class

III, according to EN 61140 (2002-03)

Enclosure rating

IP 65, according to EN 60529 (1991-10); A1 (2002-02)

EMC test

Emission: according to EN 61000-6-3 (2001-10); immunity: according to EN 61000-6-2 (2005-08)

Vibration-/ shock-test according to EN 60068-2-6 (1995) / according to EN 60068-2-27 (1993)

Weight

Standard version: 320 g with connection cable (front reading window), 340 g (side reading window) Ethernet version: 250 g without connection cables (front reading window), 270 g (side reading window)

Ambient operating temperature/ 0 ... +40 °C/–20 ... +70 °C storage temperature Max. rel. humidity

90%, no condensation

Housing colour

SICK Blue (light blue according to RAL 5012)

1) Reading gate: code evaluation time window created internally by the reading pulse 2) Ethernet version: only switching input "Sensor 1"

Tab. 10-1:

82

Technical specifications for the CLV640 Bar Code Scanner (line/raster scanner)

© SICK AG · Division Auto Ident · Germany · All rights reserved

8011975/0000/2008-04-14

Page 83

Operating Instructions

Technical data

Chapter 10

CLV640 Bar Code Scanner

10.2

Data sheet for the CLV640 Bar Code Scanner (line scanner with oscillating mirror)

The technical specifications correspond to those of the CLV640 Bar Code Scanner (line/raster scanner), except for the following variations: Type

CLV640 Bar Code Scanner

Reading window side reading window, light exit under 105° (default setting)

Useable aperture angle max. 50°

Oscillating mirror functions

Uncontrolled operation: • Fixed (position can be adjusted) or • Continuous, free oscillation Controlled operation (start/stop condition can be adjusted): • Triggered oscillation (start position and number of oscillations can be adjusted) • One-shot: One-time oscillation in forward and return motion (start position can be adjusted) In every oscillation mode, the amplitude can be adjusted separately for each of the two deflection directions. The deflection speed ratio of one deflection direction to the other can be adjusted within the selected periodic time for a complete oscillation sequence.

Oscillation frequency / Periodic time

0.5 ... 6.25 Hz / 2,000 ... 160 ms

Max. angle of deflection (amplitude)

+20° ... –20°

Current consumption

Typically 6.5 W with DC 24 V ±10 %

Weight

Standard version: 420 g Ethernet version: 350 g

Tab. 10-2:

Technical specifications for the CLV640 Bar Code Scanner (line scanner with oscillating mirror)

8011975/0000/2008-04-14

© SICK AG · Division Auto Ident · Germany · All rights reserved

83

Page 84

Chapter 10

Technical data

Operating Instructions CLV640 Bar Code Scanner

10.3 Test code

Code 39/ITF

Print ratio

2:1

Print contrast

> 90 %

Tilt

±10°

Ambient light

< 2 000 lx

Good read rate

> 75 %

Tab. 10-3:

Fig. 10-1:

Specification diagrams

Reading conditions for all specification diagrams

Meaning of selection 1, 2 and 3 in the reading area diagram related to depth of focus diagram.

Observing the reading area diagram (see figure) of the CLV640 of a module width at a focal position from the top, the selections 1, 2 and 3 can be transferred to the depth of focus diagram for this module width as follows. Therefore, the depth of focus diagram consists of a slice-shaped sequence of many reading area diagrams along the focal position.

84

© SICK AG · Division Auto Ident · Germany · All rights reserved

8011975/0000/2008-04-14

Page 85

Operating Instructions

Technical data

Chapter 10

CLV640 Bar Code Scanner

10.3.1

Fig. 10-2:

Depth of field ranges of the line scanner/raster scanner with front reading window

Line scanner/raster scanner with front reading window: min. and max. reading distance depending on the focus position and the aperture angle with a resolution of 0.2 mm (8 mil)

8011975/0000/2008-04-14

© SICK AG · Division Auto Ident · Germany · All rights reserved

85

Page 86

Chapter 10

Technical data

Operating Instructions CLV640 Bar Code Scanner

Fig. 10-3:

86

Line scanner/raster scanner with front reading window: min. and max. reading distance depending on the focus position and the aperture angle with a resolution of 0.25 mm (10 mil)

© SICK AG · Division Auto Ident · Germany · All rights reserved

8011975/0000/2008-04-14

Page 87

Operating Instructions

Technical data

Chapter 10

CLV640 Bar Code Scanner

Fig. 10-4:

Line scanner/raster scanner with front reading window: min. and max. reading distance depending on the focus position and the aperture angle with a resolution of 0.35 mm (14 mil)

8011975/0000/2008-04-14

© SICK AG · Division Auto Ident · Germany · All rights reserved

87

Page 88

Chapter 10

Technical data

Operating Instructions CLV640 Bar Code Scanner

Fig. 10-5:

88

Line scanner/raster scanner with front reading window: min. and max. reading distance depending on the focus position and the aperture angle with a resolution of 0.5 mm (20 mil)

© SICK AG · Division Auto Ident · Germany · All rights reserved

8011975/0000/2008-04-14