Page 23
Operating Instructions
Product description
Chapter 4
CLV640 Bar Code Scanner
4
Product description This chapter describes the design, the features and the functions of the CLV640 Bar Code Scanner. ¾
4.1
For installation, electrical installation and startup assistance as well as for the application-specific configuration of the bar code scanner using the SOPAS-ET configuration software, please read this chapter prior to carrying out any of the tasks.
Setting up the bar code scanner
The CLV640 Bar Code Scanner consists of a laser scanner (laser diode and lens) with dynamic focus position and an electronic unit with an integrated decoder. The laser scanner and electronic unit are located in a housing. The light exits and enters via a reading window in the industrial-type housing. The bar code scanner (depending on the version) is electrically connected by a cable with a connector or a revolving connector unit with two connections. For an adaption to on-site space conditions/reading functions three housings are available: a housing with front reading window, a housing with side reading window and a housing with oscillating mirror. Via the integrated angle attachment/oscillating mirror, the laser beam exits through the side reading window at an angle of emergence of 105°. For the oscillating mirror this corresponds to the central position (default settings) of the laser beam perpendicular to the scan direction.
8011975/0000/2008-04-14
© SICK AG · Division Auto Ident · Germany · All rights reserved
23
Page 24
Chapter 4
Product description
Operating Instructions CLV640 Bar Code Scanner
4.1.1
Fig. 4-1:
24
Device view
Housing types of the CLV640 Bar Code Scanner
© SICK AG · Division Auto Ident · Germany · All rights reserved
8011975/0000/2008-04-14
Page 25
Operating Instructions
Product description
Chapter 4
CLV640 Bar Code Scanner
Fig. 4-2:
Device view of the CLV640 Bar Code Scanner (shown here: Ethernet-Version)
8011975/0000/2008-04-14
© SICK AG · Division Auto Ident · Germany · All rights reserved
25
Page 26
Product description
Chapter 4
Operating Instructions CLV640 Bar Code Scanner
4.2
Included in delivery
Delivery of the CLV640 Bar Code Scanner includes the following components: Piece(s)
Components
Comment
1
Bar code scanner
CLV640
1
Set of laser warning signs for class 2 in German/American English and French/ American English
Self-adhesive to affix the warning sign to the bar code scanner's housing (if necessary)
1
Notes on device with electrical connection diagram as primary information
Included in the device packaging of the CLV640 Bar Code Scanner
1
CD-ROM "Manuals & Software Auto Ident" CLV640 Operating Instructions in printed Optional, depending on the number of form, in German and/or English issues explicitly ordered upon purchase
Tab. 4-1:
Important
CLV640 Bar Code Scanner delivery
The Micro-SD memory card is not included in delivery. An overview of in-stock installation accessories, connection modules, cables and connectors, sensors for reading pulses as well as memory media is available in chapter 11.4 Ordering information for bar code scanner and accessories, page 111.
Important
For save operation of the Micro-SD memory card, use only SICK approved memory card. 4.2.1
Important
26
Contents of the CD-ROM
•
"SOPAS-ET Engineering Tool“: Configuration software for WindowsTM PCs with integrated online help system (HTML files)
•
CLV640 operating instructions: PDF version in German and English as well as further publications of other SICK devices
•
“Acrobat Reader“: Freely available PC software for reading PDF files
The current versions of publications and programs on the CD-ROM can also be downloaded at www.sick.com.
© SICK AG · Division Auto Ident · Germany · All rights reserved
8011975/0000/2008-04-14
Page 27
Operating Instructions
Product description
Chapter 4
CLV640 Bar Code Scanner
4.3
Device versions
The CLV640 Bar Code Scanner with a glass reading window is available in the following versions, among others: Order no.
Type
Scanning method Reading window
Connection (design)
1042014
CLV640-0000
Line scanner
On front
Cable with connector
1042015
CLV640-0120
Line scanner
On front
Connector unit on device
1042016
CLV640-1000
*)
Raster scanner
On front
Cable with connector
1042017
CLV640-1120 *)
Raster scanner
On front
Connector unit on device
1042018
CLV640-2000 *)
Line scanner
On side
Cable with connector
1042019
CLV640-2120
*)
Line scanner
On side
Connector unit on device
1042020
CLV640-3000
*)
Raster scanner
On side
Cable with connector
1042021
CLV640-3120
*)
Raster scanner
On side
Connector unit on device
1042022
CLV640-6000
Line scanner with On side oscillating mirror
Cable with connector
1042023
CLV640-6120
Line scanner with On side oscillating mirror
Connector unit on device
*) available from q4 2008
Tab. 4-2:
Important
Variants of the CLV640 Bar Code Scanner
Depending on the connection (design), the following interfaces are available: •
Standard version (cable with connector) – RS-232, RS-422/485, CAN, two digital switching inputs, two digital switching outputs, power supply
•
Ethernet version (revolving connector unit) – Connector 1: Ethernet – Connector 2: RS-232, RS-422/485, CAN, one digital switching input, power supply
4.4
System requirements
General system requirements are derived from the bar code scanner's technical data (see chapter 10 Technical data, page 81). The requirements and conditions for Installation, Electrical installation and Startup and configuration are summarised in the respective chapters.
8011975/0000/2008-04-14
© SICK AG · Division Auto Ident · Germany · All rights reserved
27
Page 28
Chapter 4
Product description
Operating Instructions CLV640 Bar Code Scanner
4.5
Product features and functions (overview)
CLV640 Bar Code Scanner
• Dynamic focus position • Line scanner / raster scanner / line scanner with oscillating mirror • Reading window on front / side • High scan frequency • Can be adapted to the print quality of the code • Evaluation area of the scanning line can be restricted
User safety and convenience
• Robust, compact metal housing, CE mark • Laser class 2, laser switches off if the output capacity is exceeded • Automatic self-test on system startup • Diagnosis tools for system setup and system (remote) monitoring • Configurable reading diagnosis data display in two reading result formats • Operational data retrieval, error code display on request in case of errors • Activatable test string function (heartbeat) for signalling readiness for operation • Password protected configuration mode • Configured parameter values (cloning) can be additionally secured on a Micro SD memory card (can be removed in the case of bar code scanner replacement )
• Future proof due to firmware update (flash PROM) via data interface • Future-proof SOPAS-ET configuration software • Low current consumption • Extended power supply range Convenient operation/configuration
• Configuration (online/offline) using the SOPAS-ET configuration software (incl. help system)
• 2 buttons on the device for calling up preset functions without connecting a PC • Status indicators via five LEDs • Beeper that can be switched off to confirm device functioning Reading operation modi
• Start/Stop operation
Reading pulse
• Pulse sources for start: switching inputs; data interface (command); automatic cycle; CAN
• Pulse sources for stop: reading pulse source, switching inputs, command, timer, condition Bar code evaluation
• All common bar code types • Max. number of bar codes: 50 per reading pulse • Separation of identical codes of the same code type using the reading angle
Data processing
• Manipulation of the output of the reading data via event-dependent evaluation conditions
• Manipulation of the output strings through filter and output sort options Data communication
• Host interface: two data output formats configurable, switchable to different physical interfaces, parallel operation possible
• Aux interface: fixed data output format, switchable to different physical interfaces, parallel operation possible Electrical interfaces
• Host interface: RS-232, RS-422/485 (data format and protocol can be configured) and Ethernet, or CAN
• Aux interface: RS-232, (fixed data format, data transfer rate and protocol) and Ethernet
• CAN interface for integration into the SICK-specific CAN-SENSOR network • Digital switching inputs – Standard version: Two digital switching inputs for external reading pulse sensor(s) or incremental encoder, using optocoupler – Ethernet version: One digital switching input on the device • Digital switching outputs – Standard version: Two digital switching outputs for signalling definable results in the reading process (reading result status) – Ethernet version: No digital switching output on the device
28
© SICK AG · Division Auto Ident · Germany · All rights reserved
8011975/0000/2008-04-14
Page 29
Operating Instructions
Product description
Chapter 4
CLV640 Bar Code Scanner
• Standard version: Cable with 15-pole D-Sub-HD connector • Ethernet version: Revolving connector unit on the device with two M12 circular connec-
Connection technology (design)
tors
• Connection module CDB620/CDM420 for connection to the host computer (standalone) and for integrating into the SICK-specific CAN-SENSOR network
• Bus connection module CMF4001) in connection module CDM420 for connecting to field bus systems 1) Supported by SOPAS-ET from Q4 2007
Tab. 4-3:
Overview of the bar code scanner's product features and functions
4.6
Bar code scanner methods of operation
The CLV640 Bar Code Scanner is an intelligent sensor system for automatic and non-contact detection and decoding of bar codes. In principle, the codes can be detected on any side of still or moving objects in a conveyor system (single-side reading). Several bar code scanners can be combined to allow detection of several sides in one passage (multi-side reading). The bar code scanner creates a scanning line (line scanner) to recognise the codes. In the raster scanner version, the bar code scanner creates eight scanning lines that are moved parallel to each other. Line scanner with oscillating mirror The oscillating mirror additionally deflects the scanning line from the home position to both sides, perpendicular to the scanning direction, with a low oscillation frequency. This enables the bar code scanner to scan larger areas for bar codes as well. The length of the scanning line that is used for the evaluation (reading area height) depends on the reading distance because of the V-shaped light exit. The light pattern that is reflected by the bar code is recorded, processed and decoded. To control this process, external sensors deliver information via the reading pulse, the object distance and the conveyor speed (increment). The reading results are output to the bar code scanner's data interfaces and forwarded to a host/PC.
8011975/0000/2008-04-14
© SICK AG · Division Auto Ident · Germany · All rights reserved
29
Page 30
Chapter 4
Product description
Operating Instructions CLV640 Bar Code Scanner
Fig. 4-3:
Bar code scanner's methods of operation in a conveyor system (schematic)
The detailed wiring of the bar code scanner and the connections to the host/PC and to the external sensors is described in chapter 6 Electrical installation, page 51. 4.6.1
Reading configuration
The bar code scanner detects bar codes with an adjustable scan frequency. The bar code scanner can detect codes on still and moving objects. For more rapid evaluation, the reading range of the scanning line (reading angle: RA value) can be restricted. Note
The SOPAS-ET configuration software can, among other things, be used to configure the reading angle and the symbol contrast: PROJECT TREE, CLV640, PARAMETER, READING CONFIGURATION, register tab CODELABEL PROPERTIES
30
© SICK AG · Division Auto Ident · Germany · All rights reserved
8011975/0000/2008-04-14
Page 31
Operating Instructions
Product description
Chapter 4
CLV640 Bar Code Scanner
4.6.2
Object trigger control
In order to start an object-related reading process, the bar code scanner requires an appropriate external signal (trigger source) for reporting an object in the reading area. The start signal is emitted via an external reading pulse sensor (e. g. photoelectric reflex switch) as standard. As soon as an object has passed the reading pulse sensor, a time window opens in the bar code scanner (“reading gate“) for the reading process. Alternatively, a command activates the reading process via a data interface or the CAN-SENSOR network. In Automatic Cycle mode, the actual bar code scanner generates the reading gate internally with an adjustable mark-space ratio. The reading pulse can be ended in a number of ways: With external triggering by the reading pulse source or a command, internally by a timer or an evaluation condition to be met. Note
The trigger source can be configured using the SOPAS-ET configuration software: PROJECT TREE, CLV640, PARAMETER, READING CONFIGURATION, OBJECT TRIGGER CONTROL, register tab START/STOP OF OBJECT TRIGGER
4.6.3
Switchable focus position
The focus position can be changed for the CLV640 thus covering a wide reading area. You can define up to 8 reading areas for the distance configuration which can be started in any order by the lens in reading operation.
Fig. 4-4:
Switching the focus for CLV640: Division of the entire reading area in distance configurations
The focus is shifted by changing the object position (e. g. when reading downwards: detection of object height).
8011975/0000/2008-04-14
© SICK AG · Division Auto Ident · Germany · All rights reserved
31