Page 109

Operating Instructions

Appendix

Chapter 11

CLV640 Bar Code Scanner

11

Appendix 11.1

Appendix overview

The appendix contains the following additional information: •

Configuring the bar code scanner System with command strings

•

Help table for calculating the code length of a bar code

•

Ordering information

•

Supplementary documentation (overview)

•

Glossary

•

Copy of EC Declaration of Conformity

•

Code samples of bar codes

11.2

Configuring the bar code scanner with command strings

As an alternative to the SOPAS-ET configuration software, the bar code scanner can also be configured and operated with command strings via all the data interfaces. The command strings can be displayed separately via the SOPAS-ET configuration software. Important

Both the command strings and the SOPAS-ET configuration software are based on command language which directly accesses the command interpreter of the bar code scanner. This command language must be used with care as the bar code scanner executes sent commands immediately. Parameter values altered via commands are at first only active in the current parameter set in the working memory (RAM) of the bar code scanner. To save in the permanent memory, the altered parameter set must be copied into the PROM using a special command, this ensures that the alterations are not lost when the power supply is switched off. Command strings for triggering the reading pulse: •

START: <STX>sMN mTCgateon<ETX>

•

STOP: <STX>sMN mTCgateoff<ETX>

If the commands are entered via the terminal emulator in the SOPAS-ET configuration software, the two control characters <STX> and <ETX> are omitted. Connection to the bar code scanner when using the terminal emulator and Ethernet: 1.

Select TOOLS/TERMINAL in the SOPAS-ET configuration software menu to call up the terminal emulator and in the terminal emulator, select CONNECTION/CONNECT to call up the connection assistant.

2.

Select option USER DEFINED CONNECTION in the connection assistant and confirm by pressing NEXT.

3.

Select option TCP/IP and confirm by pressing NEXT.

4.

Select option SHOW ONLY COLA TELEGRAMS.

5.

Enter the bar code scanner's IP address in the relevant field and confirm by pressing NEXT.

6.

In the ADDRESSING MODE selection list, select BY NAME and confirm the settings by pressing CONNECT. The connection with the bar code scanner is established. The command strings can be transferred.

8011975/0000/2008-04-14

© SICK AG · Division Auto Ident · Germany · All rights reserved

109

Page 110

Appendix

Chapter 11

Operating Instructions CLV640 Bar Code Scanner

11.3

Calculating the code length of a bar code

The code length of a bar code corresponds to the number of characters used in the print image, including the check digit (if available). To scan (decode) a code, the code length must be input using the SOPAS-ET configuration software. Depending on the bar code type, the code length can be calculated by counting the bars and spaces according to the relevant formula in the following table. 1.

Determine the bar code type and count the bars or wide elements (bars and spaces), incl. start and stop characters according to the information in the following table.

2.

Calculate the bar code length according to the relevant formula.

3.

Enter the results via the SOPAS-ET configuration software, as shown in column 4 of the table.

Bar code type

Count

Calculating the bar code length1)2)

Input the SOPAS-ET configuration software

Code 39

Number of bars

Number – 10 ICode =, - - - - - - - - 5

Calculated code length

2/5 Interleaved

Number of wide elements (bars and spaces)

Number – 1 ICode =, - - - - - - - - 2

Calculated code length

EAN n/a

UPC n/a

13 characters (normal version)

Activate 13-digit

8 characters (short version)

Activate 8-digit

12 characters (UPC A, normal version)

Activate version A

6 characters (UPC E, short version)

Activate version E

Codabar

Number of bars

Number – 8 ICode =, - - - - - - - - 4

Calculated code length

Code 128 (character set A)

Number of bars

Number – 10 ICode =, - - - - - - - - 3

Calculated code length

EAN 128

Number of bars

Number – 10 ICode =, - - - - - - - - 3

Calculated code length

Pharmacode

Number of bars

Number

Number = code length

1) Check digit optional for code 39, 2/5 Interleaved, Codabar. Check digit is always integrated into the bar code print for EAN, UPC, code 128, code 93, EAN 128 according to the specification (automatically eliminated when the bar code scanner reading results are generated) 2) Apart from a few exceptions, every printed character represents an ASCII character which has to be decoded. Extended for code 39. The number of characters in the bar code scanner's data string may be greater than the number of characters in the print image for code 93, code 128 and EAN 128, since they are made up of several character sets.

Tab. 11-1:

110

Help table for calculating the code length of a bar code

© SICK AG · Division Auto Ident · Germany · All rights reserved

8011975/0000/2008-04-14

Page 111

Operating Instructions

Appendix

Chapter 11

CLV640 Bar Code Scanner

11.4

Ordering information for bar code scanner and accessories

11.4.1

Ordering information for CLV640 Bar Code Scanner

Order no.

Type

Scanning method Reading window

Connection (design)

1042014

CLV640-0000

Line scanner

On front

Cable with connector

1042015

CLV640-0120

1042016

Line scanner

On front

Connector unit on device

CLV640-1000

*)

Raster scanner

On front

Cable with connector

1042017

CLV640-1120

*)

Raster scanner

On front

Connector unit on device

1042018

CLV640-2000

*)

Line scanner

On side

Cable with connector

1042019

CLV640-2120

*)

Line scanner

On side

Connector unit on device

1042020

CLV640-3000 *)

Raster scanner

On side

Cable with connector

1042021

CLV640-3120 *)

Raster scanner

On side

Connector unit on device

1042022

CLV640-6000

Line scanner with On side oscillating mirror

Cable with connector

1042023

CLV640-6120

Line scanner with On side oscillating mirror

Connector unit on device

*) available from q4 2008

Tab. 11-2:

11.4.2

Variants of the CLV640 Bar Code Scanner

Accessories: Mounting devices

Order no.

Description

2020410

Fixing bracket incl. installation material. For dimensional drawing, see chapter 11.5.1 Dimensional drawing fixing bracket no. 2020410, page 117

2025526

Quick release clamp incl. installation material. For dimensional drawing, see chapter 11.5.2 Dimensional drawing of quick release clamp no. 2025526, page 118

2042800

Fixing Bracket incl. installation material. For dimensional drawing, see chapter 11.5.3 Dimensional drawing fixing bracket no. 2042800, page 119

2042801

Round rod holders for round rods and tubes with an outer diameter of 12...20 mm (0.47 ... 0.8 in), incl. installation material. For dimensional drawing, see chapter 11.5.4 Dimensional drawing of round rod holder no. 2042801, page 120

Tab. 11-3:

Fig.

In stock accessories: Installation accessories

8011975/0000/2008-04-14

© SICK AG · Division Auto Ident · Germany · All rights reserved

111

Page 112

Appendix

Chapter 11

Operating Instructions CLV640 Bar Code Scanner

11.4.3

Accessories: Connection modules

Order no.

Type

Description

1042256

CDB620-001 Connection module for a CLV640, with: • 1 x 15-pole D-Sub-HD device socket • 4 x cable connections M16 (clamping range Ø 4.5 ...10 mm (0.18 ... 0.39 in)) • Terminal strips (signal distribution unit) for wiring the data and function interfaces (digital switching inputs and outputs) • 1 x internal 9-pole D-Sub "Aux" plug • 9 x LED (status indicators) • Operating voltage 10...30 V DC • Polycarbonate housing, enclosure rating IP 651) • Operating temperature -352) ...+40 °C (-312) ... +104 °F) • Dimensions 124.2 mm x 113.1 mm x 53.9 mm (7.56 in x 6.54 in x2.74 in) • Weight approx. 260 g (9.17oz)

1042257

CDB620-101 As CDB620-001, but with: • 2 x cable connections M16 (clamping range Ø 4.5 ...10 mm (0.18 ... 0.39 in)) • 2 x 5-pole M12 circular connector (1 x plug, 1 x socket)

1042258

CDB620-201 As CDB620-001, but with: • 4 x cable connections M16 (clamping range Ø 4.5 ...10 mm (0.18 ... 0.39 in)) • 1 x cable connection M12 (clamping range Ø 4.5...7mm (0.18...0.28in))

1025362

CDM4200001

Connection module for a CLV640, with: • 1 x 15-pole D-Sub-HD device socket • 6 x cable connections M16 (clamping range Ø 4.5...10mm (0.18...0.39in)) • Terminal strips (signal distribution unit) for wiring the data and function interfaces (digital switching inputs and outputs) • 1 x internal 9-pole D-Sub "Aux" plug • 5 x LED (status indicators) • Operating voltage 10...30 V DC, current consumption 0.5 W without CLV640 • Polycarbonate housing, enclosure rating IP 651) • Operating temperature -352) ...+40 °C (-312) ... +104 °F) • Dimensions 191.9 mm x 166.2 mm x 69.7 mm (7.56in x 6.54in x2.74in) • Weight approx. 800 g (9.17oz) Application of CLV640 in combination with the parameter memory module CMC600 available from week 7/2008.

1028487

CDM4200004

As CDM420-0001, but for max. two CLV640 with: • 2 x 15-pole D-Sub-HD device sockets • 2 x internal 9-pole D-Sub "Aux" plug • 2 x 5 LED (status indicators) Application of CLV640 in combination with the parameter memory module CMC600 available from week 7/2008.

Display

1) When using a SICK scanner standard connection cable 2) Dormant (no installation or electrical installation), up to –20 °C (-4 °F)

Tab. 11-4:

112

In stock accessories: Connection modules

© SICK AG · Division Auto Ident · Germany · All rights reserved

8011975/0000/2008-04-14

Page 113

Operating Instructions

Appendix

Chapter 11

CLV640 Bar Code Scanner

11.4.4

Accessories: Extensions for connection modules

Order no.

Type

Description

1042259

CMC600101

Parameter memory module (connection module cloning) • Plug-in using connection module CDB620 or CDM420 • Storage of the parameter set of CLV640 (from firmware V 1.00) • Rotary switch for activating CLV640 network operation • Operating voltage 10 ... 30 V DC using CDB620 or CDM420 • Current consumption 0.5 W • Operating temperature 0 ... +40 °C

2029466

CDM4001)

Display module (connection display module) • In the optional housing cover for connection module CDM420 • Display of reading results and reading diagnosis data of CLV640 (from firmware V 1.00) • LCC with 4 x 20 characters, keyboard with 5 keys • Connection via flat cable • Operating voltage 18 ... 30 VDC using CDM420, current consumption 1 W • Operating temperature 0 ... +40 °C Prerequisite: Parameter memory module CMC600-101 for addressing the display.

2029468

CMP400

Power supply module (connection module power) • Installed in connection module CDM420 • Power supply of CLV640 from the alternating current network • Input voltage 100 ... 250 VAC/50 ...60 Hz • Output voltage 24 V DC, max. 10.8 W (short-circuit proof) • Connection to CDM420 via flat cable • Operating temperature 0 ... +40 °C

2030091

CMP4902)

Power supply module (connection module power) • In the optional housing cover for connection module CDM420 • Power supply of CLV640 from the alternating current network • Input voltage 100 ... 250 V AC/50 ...60 Hz • Output voltage 24 V DC, max. 25 W (short-circuit proof) • Connection to CDM420 via flat cable • Operating temperature 0 ... +40 °C

1026241

CMF4001001

Field bus gateway (connection module field bus) • Installed in connection module CDM420 • Connection of a CLV640 (from firmware V 1.00) via RS-232 data interface to Profibus DP (slave) • Changeable front panel: 9-pole D-Sub socket (bus), enclosure rating IP 20 • On the gateway in the device, 5-pole terminal strip for connecting two digital inputs and outputs each • Connection to CDM420 via connector • Operating voltage 18 ... 30 VDC using CDM420, current consumption 2 W • Operating temperature 0 ... +40 °C • Configuration with PC software "ComPro" (included in delivery) • Configuration with SOPAS-ET from Q4/2007

8011975/0000/2008-04-14

© SICK AG · Division Auto Ident · Germany · All rights reserved

Display

113

Page 114

Appendix

Chapter 11

Operating Instructions CLV640 Bar Code Scanner

Order no.

Type

Description

Display

1026643

CMF4001101

• Changeable front panel: 9-pole D-Sub socket (bus), enclosure rating

As CMF400-1001, but with: IP65

1028663

CMF4001201

As CMF400-1001, but with: • Changeable front panel: 2 x 5-pole M12 circular connector (1 x plug, 1 x socket) for bus, enclosure rating IP65

1026242

CMF4002101

Field bus gateway (connection module field bus) • Installed in connection module CDM420 • For connecting a CLV640 (from firmware V 1.00) via RS-232 data interface to DeviceNet (slave) • Changeable front panel: 5-pole M12-plug (bus), enclosure rating max. IP 65 • On the gateway in the device, 5-pole terminal strip for connecting two digital inputs and outputs each • Connection to CDM420 via connector • Operating voltage 18 ... 30 V DC using CDM490, current consumption 2 W • Operating temperature 0 ... +40 °C • Configuration with PC software "ComPro" (included in delivery) • Configuration with SOPAS-ET from Q4/2007

6029030

-

Profibus connector, IP 65, for CMF400-1101

-

1) Simultaneous operation together with power supply module CMP490 not possible 2) Simultaneous operation together with display supply module CMD400 not possible

Tab. 11-5:

In stock accessories: Extensions for connection modules

11.4.5

Accessories: Separate field bus modules

Order no.

Type

Description

1041251

CDF6000100

PROFIBUS DP Proxi • Connection of a CLV640 (from firmware V2.50) via RS-232 data interface to PROFIBUS DP • 1 x 15-pole D-Sub-HD socket for CLV640 • 1 x 5-pole M12 plug/socket for bus connection • 1 x 5-pole M12 plug for operating voltage • 1 x 4-pole M8 socket for configuration (Aux, RS-232) • 6 x LED (status indicators) • Operating voltage 24 V DC ± 20 %, current consumption type 5 W • Aluminium die casting housing, enclosure rating IP 65 • Operating temperature 0 ... + 40 °C (32 ... 104 °F) • Dimensions 225 mm (8.6 in) x 76,5 mm (3.03 in) x 47 mm (1.9 in) (without direct connections) • Weight approx. 590 g (9.17oz) • Configuration: via 3 x rotary switches and SOPAS-ET

Tab. 11-6:

114

Display

In stock accessories: Separate field bus modules

© SICK AG · Division Auto Ident · Germany · All rights reserved

8011975/0000/2008-04-14

Page 115

Operating Instructions

Appendix

Chapter 11

CLV640 Bar Code Scanner

11.4.6

Accessories: Cables for standard version

Order no.

Description

6034417

Extension cable for data and function interfaces, 15 shielded, with 15-pole D-Sub-HD socket and 15-pole, DSub-HD plug

2 m (6.56 ft) CLV640 to CDB620, CDM420

6034418

Extension cable for data and function interfaces, Ø 7 mm (0.28 in), shielded, with 15-pole D-Sub-HD socket and open end

2 m (6.56 ft) CLV640 for free wiring

6034419

Extension cable for data and function interfaces, Ø 6.8 16 x mm (0.27 in), shielded, for lengths up to 3 m (9.84 ft) 0.14 mm² (26 AWG)

2043413

Tab. 11-7:

Wires

15 x 0.16 mm² (26 AWG)

Description

6034414

Ethernet cable (patch), twisted pair, shielded, with 42x2 pole M12 round plug (D coded), IP 65 and 8-pole RJ45 plug

Wires

6030928 6034420 6034421

2041834 2042914

Ethernet cable (patch), twisted pair, shielded, with 2 x 4-pole M12 round plug (D coded), IP 65

2x2

Tab. 11-8:

CLV640 to CDB620, CDM420

Length

Connection

2 m (6.56 ft) CLV640 to Ethernet 3 m (9.84 ft) 5 m (16.4 ft)

2 m (6.56 ft) CLV640 to Ethernet 3 m (9.84 ft) 5 m (16.4 ft)

Connection cable for data and function interfaces, shielded, with 12-pole M12 round socket and 15-pole, D-Sub-HD plug, IP 67

12

0.9 m (3 ft)

CLV640 to CDB620, CDM420

2 m (6.56 ft) 3 m (9.84 ft)

2042915 6034605

Sold by the metre

10 m (32.8 ft)

6034422 2042916

3 m (9.84 ft)

Accessories: Cables for Ethernet version

Order no.

6034415

Connection

In stock accessories: Cables and connectors for the standard version of the bar code scanner

11.4.7

6029630

Length

5 m (16.4 ft) Connection cable for data and function interfaces, Ø 6.2 mm (0.24 in), shielded, with 12-pole M12 round socket and open end.

12 x 0.14 mm² (26 AWG)

5 m (16.4 ft) CLV640 for free wiring

In stock accessories: Cables and connectors for the Ethernet version of the bar code scanner

11.4.8

Accessories: General cables and connectors

Order no.

Description

Wires

Length

Connection/view

6021164

CAN data cable, shielded, twisted pair, with 5-pole M12 socket and 5-pole M12 plug, IP 65, PVC-free

2 x 0.32 mm² (28 AWG) 2 x 0.25 mm² (28 AWG)

1 m (39.37 in)

CLV640 via CDB620 to CAN bus

6021165 6021168

3 m (118.11 in) 5 m (196.85 in)

6021166

CAN data cable, Ø 6.8 mm (0.27in), shielded, twisted pair, with 5-pole M12 socket and open end (wire end ferrules), IP65, PVC-free

6021167

CAN terminal resistance, shielded, with 5-pole M12 plug, IP 65

8011975/0000/2008-04-14

2 x 0.32 mm² (28 AWG) 2 x 0.25 mm² (28 AWG)

5 m (196.85 CLV640 via CDB620 to CAN in) bus

-

© SICK AG · Division Auto Ident · Germany · All rights reserved

CAN bus connection

115

Page 116

Appendix

Chapter 11

Operating Instructions CLV640 Bar Code Scanner

Order no.

Description

Wires

Length

Connection/view

6027048

Unitronic CAN data cable, Ø 9.7 mm (0.38 in), twisted pair

2 x 2 x 0.5 mm² (21 AWG)

Sold by the metre

CAN-Bus

2014054

RS-232 data cable, shielded, with 2 x 9 -pole D-Sub 3 sockets. SICK null modem cable (pin 2 and pin 3 crossed)

3 m (118.11 CLV640 to PC in)

2030490

Data cable with 9-pole D-Sub plug and 3-pole molex 3 plug. For configuring the CMF400 with PC software "ComPro" Required in addition to the extension: Data cable no. 2014054

0.25 m (9.84 PC to CMF400 in)

6025906

Power supply line, with 5-pole M12 socket (direct), A coded and open end

5 x 0,34 mm² (28 AWG)

2 m (78.74 in)

6025908

As No. 6025906, but longer

5 x 0,34 mm² (28 AWG)

10 m (394 in)

6025909

Power supply line, with 5-pole M12 socket (90° off- 5 x 0.34 mm² set), A coded and open end (28 AWG)

2 m (78.74 in)

6025911

As No. 6025909, but longer

10 m (394 in)

6025931

Connection cable for switching input or output, with 5-pole M12 plug (direct), A coded and 5-pole M12 socket (direct), A coded

2 m (78.74 in)

CDF600 at sensors and PLC

6021195

Data cable (RS-323), shielded, with 4-pole M8 plug and 9-pole socket. For CDF600 configuration with SOPAS-ET

2 m (78.74 in)

CDF600 on PC

6021156

Terminating resistor for PROFIBUS, 5-pole M12 plug (direct), B coded

-

On PROFIBUS

6021353

5-pole M12 socket (direct), B coded, for PROFIBUS connection cable

-

-

CDF600 on PORFIBUS (Bus IN)

6021354

5-pole M12 plug (direct), B coded, for PROFIBUS connection cable

-

6021355

PROFIBUS connection, shielded

2 x 0,34 mm² (28 AWG)

Sold by the metre

4038847

Sealing rubber IP 65 for extension cables with 15pole D-Sub connectors

-

-

6009438

D-Sub connector housing (metal) for 9-pole or 15pole HD inserts

-

-

6010019

D-Sub connector insert, 15-pole HD female multipoint connector (socket), hand soldering

-

-

6010020

D-Sub connector insert, 15-pole HD male multipoint connector (plug), hand soldering

-

Tab. 11-9:

116

5 x 0,34 mm² (28 AWG)

CDF600 at power supply

CDF600 on PORFIBUS (Bus OUT) PROFIBUS network

In stock accessories: General cables and connectors for bar code scanner

© SICK AG · Division Auto Ident · Germany · All rights reserved

8011975/0000/2008-04-14