The text of a manual · part 14 of 15
Operating Instructions: CLV640 Bar Code Scanner, Advanced Line: 11 Appendix, pages 117 to 124
Pages 117 to 124 of 132, from Operating Instructions: CLV640 Bar Code Scanner, Advanced Line
The original document is the PDF (7.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Sick CLV640
Page 117
Operating Instructions
Appendix
Chapter 11
CLV640 Bar Code Scanner
11.4.9
Accessories: Reading pulse sensors
Important
The SICK catalog "SENSICK Sensoren for Automation" (order no. 8006530, English) contains a large selection of photoelectric reflex switches and photoelectric proximity switches as well as accessories (holders, connection cables). 11.4.10 Accessories: Memory Media Order no.
Description
4051366
Micro SD memory card (Flash-Card), 512 MB
Tab. 11-10: In stock accessories: Memory media for CLV640 Bar Code Scanner
11.5
Dimensional drawing accessories
11.5.1
Dimensional drawing fixing bracket no. 2020410
Included to fix the bar code scanner to the bracket: 2 x cylinder head screws M5 x 8 mm (0.32 in), with hexagon socket, self-locking Fig. 11-1:
8011975/0000/2008-04-14
Dimensions of the fixing bracket no. 2020410
© SICK AG · Division Auto Ident · Germany · All rights reserved
117
Page 118
Chapter 11
Appendix
Operating Instructions CLV640 Bar Code Scanner
11.5.2
Dimensional drawing of quick release clamp no. 2025526
Included to fix the bar code scanner to the clamp: 2 x cylinder head screws M5 x 8 mm (0.32 in), with hexagon socket, self-locking Fig. 11-2:
118
Dimensions of the quick release clamp no. 2025526
© SICK AG · Division Auto Ident · Germany · All rights reserved
8011975/0000/2008-04-14
Page 119
Operating Instructions
Appendix
Chapter 11
CLV640 Bar Code Scanner
11.5.3
Dimensional drawing fixing bracket no. 2042800
Included to fix the bar code scanner to the bracket: • 3 x cylinder head screws M5 x 8 mm (0.32 in), with hexagon socket, self-locking • 3 x spring washer A5 Fig. 11-3:
Dimensions of the fixing bracket no. 2042800
8011975/0000/2008-04-14
© SICK AG · Division Auto Ident · Germany · All rights reserved
119
Page 120
Chapter 11
Appendix
Operating Instructions CLV640 Bar Code Scanner
11.5.4
Dimensional drawing of round rod holder no. 2042801
Included to fix the bar code scanner to the holder: • 3 x cylinder head screws M5 x 8 mm (0.32 in), with hexagon socket, self-locking • 3 x spring washer A5 Fig. 11-4:
120
Dimensions of the round rod holder no. 2042801
© SICK AG · Division Auto Ident · Germany · All rights reserved
8011975/0000/2008-04-14
Page 121
Operating Instructions
Appendix
Chapter 11
CLV640 Bar Code Scanner
11.6
Supplementary documentation
Order no.
Title
Language
Contents
8012119
Operating instructions "Connection module CDB620“
German/ English
Description of the wiring for the bar code scanner with the host/PLC/sensor using connection module CDB620
8010004
Operating instructions "Connection module CDM4200001“
German/ English
Description of the wiring for the bar code scanner with the host/PLC/sensor using connection module CDM420
8011155
Operating instructions "Connection module CDM4200004“
German/ English
Description of the wiring for two bar code scanners with the host/PLC/sensor using connection module CDM420
8012120
Operating instructions "Parameter memory module CMC600“
German/ English
Description of operating the module in connection module CDB620 or CDM420
8010372
Operating instructions "Display module CMD400“
German/ English
Description of operating the module in connection module CDM420
8010365
Operating instructions "Power supply module CMP400“ German/ English
Description of installing the module in connection module CDM420
8010601
Operating instructions "Power supply module CMP490“ German/ English
Description of installing the module in connection module CDM420
8010461
Operating instructions "Field bus gateway CMF4001x01 for Profibus-DP“
German
Description of installing and operating (configuring) the module in connection module CDM420
8010463
Operating instructions "Field bus gateway CMF4002101 for DeviceNet“
German
Description of installing and operating (configuring) the module in connection module CDM420
8012213
Operating instruction "Field bus module CDF600-0100 for PROFIBUS-DP"
German
Description of installation, operation and configuration
8009179
Operating instructions "Use of the CAN interface"
German
Description of setting up a CAN scanner network (electrical connection, configuring the bar code scanner, functions) and integrating it in a CAN open network
Tab. 11-11: Supplementary documentation
8011975/0000/2008-04-14
© SICK AG · Division Auto Ident · Germany · All rights reserved
121
Page 122
Chapter 11
Appendix
Operating Instructions CLV640 Bar Code Scanner
11.7
Glossary
Also see the SOPAS-ET configuration software online help for further terms. Aperture angle α Aperture within the boundaries of which the bar code scanner is able to detect codes (through the lenses). A V-shaped area appears radially in front of the reading window, at right angles to the conveyor system (reading from above), in which the codes to be read must be positioned. Aspect ratio For bar codes with the code height (strip length) to code length (number of characters) ratio. Aux interface Logical auxiliary data interface of the bar code scanner with a fixed data output format, physically switched to RS-232 (Aux) and Ethernet (port 2111). With this data interface, access to the bar code scanner for the configuration is always possible with the PC and the SOPASET configuration software. The data interface is also used for diagnosis (output of reading diagnosis data or monitoring the data traffic on the Host interface). For the physical RS-232 interface, the following applies: fixed data format, data transfer rate 57.6 kbd. The data output to the PC via RS-232 can be switched off, existing Aux interface communication via the Ethernet interface (port 2111) remains active. Bar code Field of dark strips (bars) and light spaces (elements) arranged in parallel, which, by working to a certain rule (specification), can be represented on the medium (subsurface) by various print processes. A user-readable (alpha)numeric character is produced from each machinereadable, corresponding number and combination of strips and spaces. Since the entire coded information, framed by start and stop characters, is available as a whole in one dimension and is also usually analysed by line, bar codes are also referred to as linear codes. The various code types differ in their codeable character inventory, design (number of elements per character, number of characters, start/stop characters, check characters), their information density and in their print tolerances. The length of the code strips and spaces has no bearing on the information content. However, longer code strips and spaces can be more easily analysed by the reading device. CAN interface Physical data interface. Controls construction of a rapid SICK-specific CAN SENSOR network with various functions (e.g. multiplexer, master/slave). Access to the CLV640 Bar Code Scanner for configuration is possible via the CAN interface (network) using the SOPAS-ET configuration software in remote mode. Code geometry Code length and height dimensions.
122
© SICK AG · Division Auto Ident · Germany · All rights reserved
8011975/0000/2008-04-14
Page 123
Operating Instructions
Appendix
Chapter 11
CLV640 Bar Code Scanner
Command strings, commands User interface to the bar code scanner, as an alternative to the SOPAS-ET configuration software. The command string form a clearly structured command language for changing the parameter value sets in the bar code scanner online. Directly accesses the command interpreter of the bar code scanner. Use of the host requires a corresponding programming task. The SOPAS-ET configuration software is based on the command strings. Configuration file Project file for the SOPAS-ET configuration software in which either only one complete parameter value set for a device or, if several devices are grouped into one project, the complete parameter value set for each device, is saved for archiving on the PC. The project file can be expressed as a table, transferred to the Windows clipboard or provided as a PDF. Data output string A structured data telegram for the reading results in two independent data output formats that the bar code scanner itself prepares for output from its database. The output formats can be output via the Host interface to the physical data interfaces RS-232/RS-422/485, Ethernet or CAN. The design of the output formats is flexible (sequence of the code segments and elements, link with event conditions, filters, sorters etc.) and can be widely adapted to the application-specific requirements. Decoder, decoding From the code type-dependent analysis routine to reconstruction of the codes read in electronic form, in order to decipher the data content. Default setting The factory default setting of all of the bar code scanner’s parameter values is saved in its permanent memory and can be reloaded at any time when the device is connected using the CLV640 menu to the bar code scanner’s working memory. This rejects all changes that were made in an application-specific configuration if they were not permanently saved in SOPAS-ET after the request. If necessary, the data connection to the bar code scanner itself is lost. However, the application-specific basic setting enables all parameter values except for those for the communication parameter to be set to the factory default settings. The existing communication with the bar code scanner remains unaffected. Deflection angle Angle which the scanning line covers at both sides each of the central position CW=50 (corresponds to 0°) when deflected by the oscillating mirror. Also called oscillation angle. Deflection range Deflection of the scanning line by way of the oscillating mirror across the scanning direction to both sides of the central position CW=50 (corresponds to a light exit under 105° (default setting)). Also called oscillation amplitude.
8011975/0000/2008-04-14
© SICK AG · Division Auto Ident · Germany · All rights reserved
123
Page 124
Chapter 11
Appendix
Operating Instructions CLV640 Bar Code Scanner
Distance configuration Data set in the bar code scanner to establish a focus position of the laser beam for focus position switching. The depths of field for the individual focus positions can be obtained from the specification diagram in relation to the resolution. Distance detection Device detecting in 2 graduation distances from objects carrying the bar codes. One example is the downward reading of a photoelectric reflex switch arranged beside the conveyor system. The ranges for focus position switching are defined through combinations of the switched input "Sensor 1" and the cross-reference list for distance configurations. Download Transfer process of the parameter values using the SOPAS-ET configuration software from the PC to the connected bar code scanner. In "Online" communication mode, the SOPAS-ET configuration software always transfers the just modified parameter values in the background automatically and temporarily to the working memory (RAM) of the bar code scanner with the "Immediate download" option (default setting). With this option, the current parameter values in the bar code scanner are constantly synchronised with the modifications that are made on the user interface. With the "Download on request" option, the user is responsible for comparing them manually. If individual parameter values have unsynchronized statuses between SOPAS-ET and the connected bar code scanner, SOPAS-ET identifies these parameters with a blue frame. Using the context menu (right mouse button), if necessary the modified parameter value on a register tab (DOWNLOAD PARAMETER VALUE) can be transferred manually to the bar code scanner. Using the Communication menu, either modified parameter values only (DOWNLOAD MODIFIED PARAMETERS TO DEVICE) or all of the bar code scanner’s parameter values (DOWNLOAD ALL PARAMETERS TO DEVICE) can be transferred. The parameter values that were temporarily changed in the bar code scanner are only saved permanently when the storage option "Permanent" (menu CLV640) is selected. The transferable parameter values depend on the current user level in SOPAS-ET. Error messages Messages in coded form with which the bar code scanner displayed a diagnosed error. The bar code scanner differentiates between four error types: Information, Warning, Error, Fatal Error. The error messages can be displayed in the SOPAS-ET configuration software on the System Informationen register tab. Ethernet interface Physical data interface with transfer rate 10/100 MBit/s and TCP/IP protocol. The Ethernet interface can be used alternatively to and also in parallel with the physical interfaces RS232, RS-422/485. Port 2112 (Host interface) is used to output the reading result and port 2111 (Aux interface) among other things is used to output reading diagnosis data and to monitor the data traffic on the Host interface. The bar code scanner can be configured using both ports. If the Aux interface data output via RS-232 is eliminated, existing communication via Ethernet remains active. The same applies to the Host interface, although the data output via Ethernet can be eliminated separately.
124
© SICK AG · Division Auto Ident · Germany · All rights reserved
8011975/0000/2008-04-14