Page 11

Operating Instructions

Notes on this document

Chapter 1

CLV640 Bar Code Scanner

1

Notes on this document 1.1

Purpose

This document provides instructions for technical staff on the installation and operation of the bar code scanner series CLV640 with dynamic focus position in the following versions: •

Line scanner / raster scanner / line scanner with oscillating mirror

•

With front / side reading window

•

With cable and connector (standard version) / with connector unit (Ethernet version)

A summary of all device versions is shown in chapter 4.3 Device versions, page 27. This document contains the following information: •

Installation

•

Electrical installation

•

Startup and configuration

•

Maintenance

•

Troubleshooting

•

Replacing the bar code scanner

A step-by-step approach is taken for all tasks.

1.2

Target group

The target group of this document is persons assigned the following tasks: Tasks

Target group

Installation, electrical installation, maintenance, Qualified staff, e.g. service technicians and facreplacing the device tory electricians Startup and configuration

Trained staff, e.g. technicians or engineers

Operation of the conveyor system

Qualified staff for start-up and operation of the conveyor system

Tab. 1-1:

1.3

Target group

Depth of information

This document contains all the required information for installation, electrical installation and operation of the bar code scanner at the installation location. The factory default setting (basic configuration) of the bar code scanner is prepared for the use as a stand-alone device. Configuration of the bar code scanner for the application-specific reading conditions and operation is carried out using the SOPAS-ET configuration software on a WindowsTM PC. The SOPAS-ET configuration software contains an online help system to facilitate configuration. Important

Further information about the design of the bar code scanner as well as the bar code technology is available from SICK AG, Auto Ident division. On the Internet at www.sick.com.

8011975/0000/2008-04-14

© SICK AG · Division Auto Ident · Germany · All rights reserved

11

Page 12

Notes on this document

Chapter 1

Operating Instructions CLV640 Bar Code Scanner

1.4

Used symbols

To gain easier access, some information in this documentation is emphasised as follows:

Notice! ¾

Indicates a potential risk of damage or impair on the functionality of the bar code scanner or other devices.

Warning notice! A warning notice indicates real or potential danger. This should protect you against accidents. The safety symbol next to the warning notice indicates why there is a risk of accident, e.g. due to electricity. The warning levels (DANGER, WARNING, CAUTION) indicate the seriousness of the risk. ¾

Carefully read and follow the warning notices!

Reference

Italic script denotes a reference to further information.

Important

This important note informs you about specific features.

Explanation Recommendation TIP PROJECT

An explanation provides background knowledge of technical nature. A recommendation helps you to carry out tasks correctly. A tip explains setting options in the SOPAS-ET configuration software. This type of script denotes a term in the user interface in the SOPAS-ET configuration software. A symbol indicates a button in the user interface of the SOPAS-ET configuration software. There is a procedure which needs to be carried out. This symbol indicates operational instructions which only contain one operational step or operational steps in warning notices which do not have to be followed in any particular order. Operational instructions comprising several steps are denoted using consecutive numbers. This symbol indicates a reference to other information in the glossary. Note

This symbol denotes a section in which the operation steps with the SOPAS-ET configuration software are described.

Important

This symbol indicates supplementary technical documentation.

12

© SICK AG · Division Auto Ident · Germany · All rights reserved

8011975/0000/2008-04-14

Page 13

Operating Instructions

Safety information

Chapter 2

CLV640 Bar Code Scanner

2

Safety information This chapter deals with your safety and operator safety in the operational area. ¾

Read this chapter carefully before using the bar code scanner.

2.1

Authorised users

For correct and safe functioning, the bar code scanner must be installed, operated and maintained by sufficiently qualified staff. Repairs to the bar code scanner should only be carried out by qualified and authorised SICK AG service staff. ¾

The operating instructions should be made available to the end user.

¾

The end user should be briefed and urged to read the operating instructions by the technicians.

The following qualifications are required for different activities: Tasks

Qualification

Installation, maintenance

• Practical technical training • Knowledge of current health and safety regulations at the workplace

Electrical installation, device • Practical electrical training replacement • Knowledge of current electrical safety regulations • Knowledge of start-up and operation of the device in each operational area (e. g. conveyor system) Startup, configuration

• Basic knowledge of the WindowsTM operating system • Basic knowledge of designing and setting up (addressing) Ethernet connections for connecting the bar code system to the Ethernet

• Basic knowledge of working with an HTML browser (e. g. Internet ExplorerTM) for using the online help • Basic knowledge of data transfer • Basic knowledge of bar code technology Operation of the device in each operational area

• Knowledge of start-up and operation of the device in each operational area (e. g. conveyor system)

• Knowledge of the software and hardware environment in each operational area (e. g. conveyor system) Tab. 2-1:

8011975/0000/2008-04-14

Required qualification for starting up the bar code scanner

© SICK AG · Division Auto Ident · Germany · All rights reserved

13

Page 14

Safety information

Chapter 2

Operating Instructions CLV640 Bar Code Scanner

2.2

Intended use

The CLV640 Bar Code Scanner is an intelligent sensor for the automatic recognition and decoding of bar codes on objects e.g. in a conveyor system. The intended use of the bar code system results from the following description of the function:

Important

•

In a reading station, the bar code scanner is installed in a holder, either on the side of a conveyor system (side reading) or above it (reading from above).

•

The bar code scanner transfers the reading data via the host interface to a superordinate host computer for further processing.

•

The bar code scanner is configured/operated using the SOPAS-ET configuration software that runs on a standard client PC provided by the customer. Communication takes place using RS-232 or Ethernet.

Any warranty claims against SICK AG shall be deemed invalid in the case changes to the bar code scanner, such as opening the housing, this includes modifications during installation and electrical installation or changes to the SICK software. The bar code scanner is only to be operated in ambient air temperature limit.

2.3 ¾

General safety precautions and protection measures Read the general safety precautions thoroughly and observe them during all bar code scanner activities. Also observe the warning notices above the operational instructions of each chapter.

2.3.1

Electrical installation work

Risk of injuries due to electrical current! The optional power supply module CMP400/CMP490 is connected to the power supply (100 ... 250 V AC/50 ... 60 Hz) in connection module CDM420. ¾

Important

Observe current safety regulations when working with electrical equipment.

Electrical installation should only be carried out by qualified staff. Connect or release current linkages only under de-energised conditions. Wire cross sections and their correct shields have to be selected and implemented according to valid engineering standards.

14

© SICK AG · Division Auto Ident · Germany · All rights reserved

8011975/0000/2008-04-14

Page 15

Operating Instructions

Safety information

Chapter 2

CLV640 Bar Code Scanner

2.3.2

Fig. 2-1:

Laser radiation of the bar code scanner

Outlet opening of the laser radiation at the reading window (shown here: Ethernet version)

Damage to the eyes through laser radiation! The bar code scanner operates with an red light laser of class 2. Looking at the laser's light path for a longer period of time can damage the eye's retina. The entire reading window is the LED radiation outlet opening. Caution - use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure.

Important

¾

Never look directly into the light path (similar to sun light).

¾

Never direct the device's laser beam at the eyes of persons.

¾

When installing and aligning the bar code scanner, avoid laser beam reflections from reflective surfaces.

¾

Do not open the housing. (Opening does not interrupt the activation of the laser diode by the reading pulsing.)

¾

Always observe the latest valid version of laser protection regulations.

Bar code scanners in series CLV640 operate with a laser of wavelength λ = 655 nm (red light). The radiation emitted is not harmful to human skin. The product is classified in laser class 2 (laser class II) in accordance with EN 60825-1, IEC 60825-1 and 21 CFR 1040.10 (see the warning sign on the device for the date of publication) Maintenance is not required to ensure compliance with laser class 2. The bar code scanner displays a black and yellow laser warning sign.

8011975/0000/2008-04-14

© SICK AG · Division Auto Ident · Germany · All rights reserved

15

Page 16

Safety information

Chapter 2

Operating Instructions CLV640 Bar Code Scanner

Standard version

Fig. 2-2:

Laser warning sign attached to the bar code scanner at delivery

Device

CLV640

Laser out radiation (maximum/average)

3.2 mW/ <1.0 mW

Emitted wavelength

655 nm

Pulse duration

< 300 μs

Tab. 2-2:

Important

Ethernet version

Laser Data of CLV640

If the bar code scanner is installed in a machine/panelling in such a way that the bar code scanner's laser warning sign is hidden, additional warning signs in the same language (not included in delivery) have to be attached to the machine next to the outlet opening of the laser radiation! The bar code scanner works as follows in controlling the laser diodes: •

The bar code scanner has monitoring switches that deactivate the laser diode if irregularities occur in the radiation emission.

•

The reading pulse (pulse source) controls the on and off mechanism of the laser diode during the reading process.

•

During reading operation with "Sensor" and "Command" reading pulses, each time level (laser timeout) switches off the laser diode automatically after 10 minutes (default settings) when a permanent reading pulse has been started. However, it does not stop the reading pulse. The reading pulse can be stopped via an appropriate clock signal. The successive reading pulse switches on the laser diode.

•

16

In SOPAS-ET on the "Illumination control" tab you can set or deactivate the laser timeout within a range of 1 ... 1,500 min (= 25h).

© SICK AG · Division Auto Ident · Germany · All rights reserved

8011975/0000/2008-04-14

Page 17

Operating Instructions

Safety information

Chapter 2

CLV640 Bar Code Scanner

•

"Laser" LED: During normal reading operation the "Laser" LED lights up when the laser diode is switched on. When calling up functions via the two buttons of the bar code scanner (aborting normal reading operation), the LEDs have got additional display functions. The "Laser" LED will differ from its original function. It is possible that the "Laser" LED is flashing when Autosetup is selected, although the laser diode is still switched off or the laser diode is switched on, for example, in diagnostic mode (Read Diagn) and the "Laser" LED, however, is not flashing.

2.4

Quick stop and quick restart

The bar code scanner can be switched on or off using the main switch for connection modules CDB620 or CDM420. 2.4.1 ¾

Switching off the bar code scanner

Switch off the power supply to the bar code scanner (the connection module) - or Remove (pull out) the 15-pole D-Sub-HD connector of the bar code scanner's connection cable from the connection module.

When the bar code scanner is switched off, the following data is lost: •

Application-specific parameter sets in the bar code scanner that were only saved temporarily in the device

•

The last reading result of the bar code scanner

•

Daily operating hours counter of the bar code scanner

2.4.2 ¾

Switching the bar code scanner back on

Switch the power supply to the bar code scanner (the connection module) back on - or Connect the 15-pole D-Sub-HD connector of the bar code scanner's connection cable to the connection module. The bar code scanner starts up using the most recent permanently saved configuration. The daily operating hours counter is reset.

8011975/0000/2008-04-14

© SICK AG · Division Auto Ident · Germany · All rights reserved

17

Page 18

Chapter 2

Safety information

Operating Instructions CLV640 Bar Code Scanner

2.5

Environmental information

The bar code scanner has been constructed with minimum environmental pollution in mind. Excluding the housing, the bar code scanner does not contain any materials using silicone. 2.5.1

Energy requirements

The bar code scanner series CLV640 consumes the following energy: •

Line / Raster scanner: Typically 5.5 W with 24 V DC ± 10 %

•

Line scanner with oscillating mirror: Typically 6.5 W with 24 V DC ± 10 %

All values with unwired switching outputs. 2.5.2

Dispose of the device after decommissioning

SICK AG will not currently accept the return of any devices which can no longer be operated or repaired. ¾

Inoperable or irreparable devices must be disposed of in an environmentally friendly manner and in accordance with valid country-specific waste disposal guidelines.

The design of the bar code scanner allows for its separation as recyclable secondary raw materials and hazardous waste (electronic scrap).

18

© SICK AG · Division Auto Ident · Germany · All rights reserved

8011975/0000/2008-04-14