Page 1 of SR60 Scanner Programmer's Reference Manual

Manual · Intermec

SR60 Scanner Programmer's Reference Manual

Manual194 pagesPDF 2.0 MB

Programmer's reference manual for the Intermec SR60 laser scanner: interface settings, label transmit options and symbologies.

Download the PDF2.0 MB

Covers · 1 model

The models it covers

Summary

What is in it

The programmer's reference manual for the Intermec SR60 laser scanner, in its standard range (SR) and extended long-range (XLR) versions. It explains programming mode and sessions with programming bar codes, LEDs and beeper, changing the interface cable, and configuring the wand emulation, keyboard wedge, RS-232 and USB interfaces, prefixes, suffixes and label IDs, each symbology's options, and general features such as beeper, marker beam, low power mode and half angle. Appendices list factory defaults and reference charts.

Its parts

  1. Before You Begin
  2. Learning About Programming the SR60 Scanner
  3. Configuring Interface Settings
  4. Configuring Label Transmit Settings
  5. Enabling and Configuring Symbologies
  6. Configuring General Features

From the manual

Key facts from this manual

Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.

The programmer's reference manual for the Intermec SR60 laser scanner, in its standard range (SR) and extended long-range (XLR) versions. It shows how to set up the scanner by scanning programming bar codes: interface settings, prefixes and suffixes, symbologies, beeper, marker beam and power features. It also lists the factory defaults and the RS-232 host commands.

Read for this summary: pages 2 to 3, 11 to 13, 15 to 26, 33 to 34, 56, 84 to 85, 160 to 163, 166 to 170, 177 and 194 of 194.

Device
Laser scanner in a standard range (SR) or extended long-range (XLR) version p. 16
XLR scan range
XLR: bar code labels from as far as 11 m (36 ft), depending on the labels p. 16
Interfaces by C/N
SR60BX01 or SR60BL01: wand emulation, RS-232, keyboard wedge; SR60BX02 or SR60BL02: USB; SR60BX03 (XLR): laser emulation p. 23
SR or XLR
Sixth character of the C/N on the label above the trigger: L for SR, X for XLR p. 16
Interface cables
Laser emulation, wand emulation, RS-232, keyboard wedge, USB p. 22
Symbologies
Code 39, PharmaCode 39, Code 128, UCC/EAN 128, Interleaved 2 of 5, Codabar, UPC-A, UPC-E, EAN-13, EAN-8, Code 93, Standard 2 of 5/IATA, MSI/Plessey p. 84, 85, 169
Keyboard wedge cables
P/N 321-635-002 and P/N 321-636-002 p. 34
Programming
Scan the SET bar code, the feature bar codes, then END; a limited set of host commands also works p. 17
RS-232 host commands
D disables, E enables, R resets the scanner; B sounds a good read tone p. 177
Indicators
Amber Laser On LED and green Good Read LED on the top rear; beeper sounds six rapid chirps for an error p. 21, 22
Low Power mode
Powers the scanner down between trigger pulls; shutdown delay 0, 2, 5 or 10 seconds; not on USB p. 160, 162
Code 128 and Code 93
Preset to read labels of 1 to 50 characters p. 85
Cable screw torque
0.67 to 1.13 Nm (6 to 10 in-lb) p. 24
Document numbers
This manual P/N 937-004-004 Rev A; SR60 Scanner Quick Start Guide P/N 930-141-xxx p. 26, 194

What this manual walks you through

  • Running a programming session with the SET and END bar codes p. 17, 18, 19
  • Telling the SR version from the XLR version p. 16
  • Changing the interface cable p. 23, 24
  • Restoring factory default settings p. 25
  • Selecting the PC keyboard wedge interface type p. 33, 34
  • Enabling the USB interface and setting the keyboard country code p. 56
  • Enabling and disabling symbologies p. 84, 85
  • Setting Low Power mode and its shutdown delay p. 160, 161, 162
  • Setting the half scan angle p. 163
  • Controlling the scanner with RS-232 host commands p. 177

Good to know

  • If power is lost before the END bar code is scanned, the new settings are discarded. p. 19
  • Scanning a bar code that changes the interface type loses everything scanned earlier in that session. p. 18
  • The factory defaults bar code does not reset Low Power mode or Half Angle. p. 25
  • With the USB interface, the USB enable bar codes must be scanned, or some conditions corrupt data. p. 56
  • Low Power mode is recommended only when the scanner is connected to a battery-powered terminal. p. 160

Questions this manual answers

How do I tell if my SR60 is the SR or XLR version?

Look at the sixth character of the configuration number (C/N) on the label above the trigger: L means the SR version, X means the XLR version. p. 16

How far can the SR60 XLR scan?

The XLR version reads bar code labels from as far as 11 m (36 ft), depending on the labels. p. 16

How do I reset the SR60 to factory defaults?

Scan SET, then the Return to Factory Default Settings bar code, then END. Low Power mode and Half Angle are not reset this way. p. 25

Which SR60 works with USB?

The scanners with C/N SR60BX02 (XLR) or SR60BL02 (SR) support the USB interface. p. 23

What keyboard wedge cable does the SR60 use?

The manual lists P/N 321-635-002 and P/N 321-636-002, depending on the PC keyboard interface type. p. 34

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. Before You Begin11
    1. About Cautions and Notes11
    2. Global Services and Support11
    3. Who Should Read This Manual13
    4. Related Documents13
  2. Chapter 1 - Learning About Programming the SR60 Scanner15
    1. What Is the SR60?16
    2. Customizing Your Scanner’s Operation16
    3. How to Program the SR60 Scanner17
    4. About the Scanner LEDs and Beeper21
    5. Integrating the Scanner With Your Host System22
    6. Changing the Interface Cable23
    7. Restoring Factory Default Settings25
    8. Trouble Scanning the Bar Codes in This Manual26
    9. Contacting Intermec Product Support26
  3. Chapter 2 - Configuring Interface Settings27
    1. Wand Emulation Interface28
    2. Keyboard Wedge Interface33
    3. RS-232 Communication Parameters45
    4. USB Interface56
  4. Chapter 3 - Configuring Label Transmit Settings61
    1. When to Configure Label Transmit Settings62
    2. How to Use the Prefix, Suffix, and Label ID62
    3. Setting Global Prefixes and Suffixes63
    4. Setting a Prefix or Suffix67
    5. Setting a Label ID73
  5. Chapter 4 - Enabling and Configuring Symbologies83
    1. All Symbologies Supported by All Interfaces84
    2. Enabling Symbologies84
    3. Code 39/PharmaCode 39 Options89
    4. Code 128 and UCC/EAN 128 Options97
    5. Interleaved 2 of 5 Options101
    6. Codabar Options110
    7. UPC/EAN Options120
    8. Code 93 Options131
    9. Standard 2 of 5/IATA Options135
    10. IATA Options143
    11. MSI/Plessey Options144
  6. Chapter 5 - Configuring General Features153
    1. Configuring the Green LED Idle State154
14 more lines, from page 154 on
  1. Configuring the Beeper Settings154
    1. Configuring the Marker Beam158
    2. Configuring the Low Power Mode160
    3. Configuring the Low Power Shutdown Delay162
    4. Configuring the Half Angle163
  2. Appendix A - Factory Default Configuration165
    1. Factory Default Configuration166
  3. Appendix B - Reference Information171
    1. Sample Bar Codes172
    2. Keypad Bar Codes174
    3. RS-232 Host Commands177
    4. ASCII Character Set178
    5. Full ASCII Chart179
    6. ASCII Extended Chart189

From the PDF’s own bookmarks.

The whole text · 22 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 101-10
  2. Before You Begin11-14
  3. Chapter 1 - Learning About Programming the SR60 Scanner15-26
  4. Chapter 2 - Configuring Interface Settings, pages 27 to 3527-35
  5. Chapter 2 - Configuring Interface Settings, pages 36 to 4436-44
  6. Chapter 2 - Configuring Interface Settings, pages 45 to 5345-53
  7. Chapter 2 - Configuring Interface Settings, pages 54 to 6054-60
  8. Chapter 3 - Configuring Label Transmit Settings, pages 61 to 6861-68
  9. Chapter 3 - Configuring Label Transmit Settings, pages 69 to 7669-76
  10. Chapter 3 - Configuring Label Transmit Settings, pages 77 to 8277-82
  11. Chapter 4 - Enabling and Configuring Symbologies, pages 83 to 9283-92
  12. Chapter 4 - Enabling and Configuring Symbologies, pages 93 to 10293-102
  13. Chapter 4 - Enabling and Configuring Symbologies, pages 103 to 112103-112
  14. Chapter 4 - Enabling and Configuring Symbologies, pages 113 to 122113-122
  15. Chapter 4 - Enabling and Configuring Symbologies, pages 123 to 132123-132
  16. Chapter 4 - Enabling and Configuring Symbologies, pages 133 to 142133-142
  17. Chapter 4 - Enabling and Configuring Symbologies, pages 143 to 152143-152
  18. Chapter 5 - Configuring General Features153-164
  19. Appendix A - Factory Default Configuration165-170
  20. Appendix B - Reference Information, pages 171 to 178171-178
  21. Appendix B - Reference Information, pages 179 to 186179-186
  22. Appendix B - Reference Information, pages 187 to 194187-194

The file

Revision and size

RevisionP/N 937-004-004 Rev A, 12/2006
PublisherIntermec Technologies Corporation
Pages194
PDF2.0 MB
TextText from the PDF itself; 17 pages are scans, read by OCR, which may hold reading errors.

The first pages · 3 of 194

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 194
Page 2
Page 2of 194
Page 3
Page 3of 194

More documents · 2