The text of a manual · part 11 of 22
SR60 Scanner Programmer's Reference Manual: Chapter 4 - Enabling and Configuring Symbologies, pages 83 to 92
Pages 83 to 92 of 194, from SR60 Scanner Programmer's Reference Manual
The original document is the PDF (2.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec SR60
Page 83
and Configuring 4 Enabling Symbologies
This chapter explains that all symbologies are supported by all the interfaces, describes the symbologies, and contains programming bar codes for configuring symbology features and options. You will find these sections in this chapter: • All Symbologies Supported by All Interfaces • Enabling Symbologies • Code 39/PharmaCode 39 Options • Code 128 and UCC/EAN 128 Options • Interleaved 2 of 5 Options • Codabar Options • UPC/EAN Options • Code 93 Options • Standard 2 of 5/IATA Options • IATA Options • MSI/Plessey Options
SR60 Scanner Programmer’s Reference Manual
69
Page 84
Chapter 4, Enabling and Configuring Symbologies
All Symbologies Supported by All Interfaces You can enable any bar code symbology described in this chapter because all the symbologies in this chapter are supported by all the SR60 scanner interface types. Identify the symbologies you want to enable. Use the bar codes in this chapter to enable those symbologies and set the data format options (such as check digit or start/stop characters) required by your host system for each symbology type. You must enable the symbology format options settings that are compatible with your host system. The factory default settings for each interface were chosen to meet the standard industry requirements. In most cases you do not need to change the symbology format settings. If you are unsure of your system requirements, test the scanner using the factory settings before making any changes. For a list of factory default settings, see Appendix A, “Factory Default Configuration” on page 151.
Enabling Symbologies You can enable specific symbologies or disable all symbologies using these programming bar codes: • The Disable All Symbologies bar code on page 72 lets you disable all the symbologies currently enabled on the scanner. To optimize scanner performance, you should scan this bar code before you enable only the symbologies you require. • The Enable Code 39 bar code on page 72 selects Code 39 as an active symbology and allows selection of check digit, start/ stop and single digit options. • The Enable PharmaCode 39 bar code on page 73 is a symbology subset of Code 39. Enabling PharmaCode 39 allows the scanner to read both PharmaCode 39 and Standard Code 39 labels. Note: Standard Code 39 must be enabled before you can enable PharmaCode.
70
SR60 Scanner Programmer’s Reference Manual
Page 85
Chapter 4, Enabling and Configuring Symbologies
• The Enable Code 128 bar code on page 73 selects Code 128 as an active symbology. The scanner is preset to recognize all Code 128 bar codes that have between 1 and 50 characters. • The Enable UCC/EAN 128 bar code on page 73 chooses EAN 128 as an active symbology. The Automatic Identification Manufacturers, Inc. of the United States (AIM U.S.A.) have standardized the reporting of data sources from bar code reading devices. Sending the AIM symbology prefix identifies the symbology to the host terminal, allowing it to specifically differentiate between UCC/EAN-128 (Code 128 with Function Character 1 in the first position) and standard Code 128 symbols. When this feature is disabled, the host cannot differentiate between these symbols. • The Enable Interleaved 2 of 5 bar code on page 73 selects Interleaved 2 of 5 as an active symbology. Allows change of check digit or label format (fixed or variable length) options. • The Enable Codabar bar code on page 73 selects Codabar as an active symbology. Allows selection of check digit, start/stop character and format, or label format (fixed or variable length) options. • The Enable UPC-A bar code on page 73 enables UPC-A as an active symbology. If you enable this symbology, additional options for symbology expansion and reading add-on are available. • The Enable UPC-E bar code on page 73 tells the scanner to recognize UPC-E as an active symbology. Like UPC-A, UPCE offers options for symbology expansion and reading of addons. • The Enable EAN-13 bar code on page 74 selects EAN-13 as an active symbology. EAN-13 options are similar to those of the EAN-8 symbology. • The Enable EAN-8 bar code on page 74 selects EAN-8 as an active symbology. EAN-8 symbology selection also allows options for symbology expansion and reading of add-ons. • The Enable Code 93 bar code on page 74 enables Code 93 as an active symbology. The scanner is preset to recognize all Code 93 bar codes that have between 1 and 50 characters.
SR60 Scanner Programmer’s Reference Manual
71
Page 86
Chapter 4, Enabling and Configuring Symbologies
• The Enable Standard 2 of 5 bar code on page 74 selects Standard 2 of 5 as an active symbology. Options for this symbology are similar to Interleaved 2 of 5 features. • The Enable IATA bar code on page 74 selects the IATA custom code (which is a special symbology subset of Standard 2 of 5) as the active Standard 2 of 5 symbology, superseding any other Standard 2 of 5 features. Note: Standard 2 of 5 must be enabled in order for IATA to be active. However, while IATA is enabled, Standard 2 of 5 is not decoded. • The Enable MSI/Plessey bar code on page 74 selects MSI/ Plessey as an active symbology. Allows selection of check digit or label format (fixed or variable length) options. Scan the following bar codes to enable specific symbologies or disable all symbologies. Note: If you enable a symbology that has additional features that should be set, turn to the pages that support that symbology and its programmable features. .
SET-------------------------------------
Disable All Symbologies
---------
Symbology Selections
Enable Code 39
72
---------
SR60 Scanner Programmer’s Reference Manual
Page 87
Chapter 4, Enabling and Configuring Symbologies
Enable PharmaCode 39
---------
Enable Code 128
---------
Enable UCC/ EAN 128
---------
Enable Interleaved 2 of 5 ---------
Enable Codabar
---------
Enable UPC-A
---------
Enable UPC-E
---------
SR60 Scanner Programmer’s Reference Manual
73
Page 88
Chapter 4, Enabling and Configuring Symbologies
Enable EAN-13
---------
Enable EAN-8
---------
Enable Code 93
---------
Enable Standard 2 of 5
---------
Enable IATA
---------
Enable MSI/ Plessey
---------
END------------------------------------
74
SR60 Scanner Programmer’s Reference Manual
Page 89
Chapter 4, Enabling and Configuring Symbologies
After enabling one or more symbologies, you can use the bar codes in the following sections to configure the symbology options and features.
Code 39/PharmaCode 39 Options This section describes the Code 39 options and contains the programming bar codes you can use to configure those options.
About Code 39 Options The Code 39 symbology has the following programmable features: • Check Digit • Start/Stop Characters • Code 39 Full ASCII • Minimum Label Length • Read Verification • Code 39 Emulate Function Keys (USB interface only)
Check Digit Check Digit calculates the check digit to verify that the check digit contained in the bar code label is correct. If you enable this feature, your bar codes must contain a check digit.
Start/Stop Characters Start/Stop Characters selects either Send or Don’t Send depending on your host’s interface requirement.
Code 39 Full ASCII Code 39 Full ASCII enables or disables the ability to decode Code 39 Full ASCII labels.
Minimum Label Length Minimum Label Length sets the minimum label length required for the Code 39 symbology. This feature causes the scanner to ignore small label segments, reducing the possibility that a portion of a good label is incorrectly seen as an entire label.
Read Verification Read Verification is the number of times the scanner is required to read the bar code data before sending the label data to the host.
SR60 Scanner Programmer’s Reference Manual
75
Page 90
Chapter 4, Enabling and Configuring Symbologies
Code 39 Emulate Function Keys (USB interface only) Code 39 Emulate Function Keys converts Code 39 character pairs to their equivalent ASCII extended values. For example, with this feature enabled, if you scan a Code 39 bar code that contains a period and capital N (.N), you get the F1 keyboard function. For a list of keyboard functions, see the “ASCII Extended Chart” on page 175.
Configuring the Code 39 Options Scan the following bar codes to configure the Code 39 options.
SET------------------------------------
Check Digit
76
Don’t Calculate
---------
Calculate
---------
Don’t Transmit
---------
Transmit
---------
SR60 Scanner Programmer’s Reference Manual
Page 91
Chapter 4, Enabling and Configuring Symbologies Start/ Stop
Don’t Transmit
---------
Transmit
---------
Code 39 Full ASCII
Enable
---------
Disable
---------
END------------------------------------
Minimum Label Length The following procedure explains how to set the Code 39 Minimum Label Length. To set Code 39 Minimum Label Length 1 Identify the minimum label length setting you want to make. The selectable range is 00 to 48 characters.
SR60 Scanner Programmer’s Reference Manual
77
Page 92
Chapter 4, Enabling and Configuring Symbologies \
Note: For this symbology, the scanner decodes up to 48 characters, but the actual length read varies depending upon interface type, bar code physical size, and print quality. Code 39 bar codes containing one or more full ASCII characters can also limit the amount of characters that are decoded; in these circumstances, the scanner decodes at least 24 data characters. 2 Scan the SET bar code. 3 Scan the Set Minimum Label Length bar code. 4 Using the Digits bar codes on page 79, scan the digits to set the minimum label length you identified in Step 1. Note: To set a label length less than ten, you must scan a zero digit first and then the length digit (such as 04, 06, or 08). 5 Scan the END bar code. Minimum Label Length
SET------------------------------------
Set Minimum Label Length
---------
END------------------------------------
78
SR60 Scanner Programmer’s Reference Manual