The text of a manual · part 10 of 22
SR60 Scanner Programmer's Reference Manual: Chapter 3 - Configuring Label Transmit Settings, pages 77 to 82
Pages 77 to 82 of 194, from SR60 Scanner Programmer's Reference Manual
The original document is the PDF (2.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec SR60
Page 77
Chapter 3, Configuring Label Transmit Settings
5 Scan the END bar code. You have changed the default Label ID for UPC-A from A to A1.
Selecting the Symbology This section contains bar codes that represent each symbology. You scan these bar codes when, for example, you configure a symbology-specific label ID. You may scan only one symbology per programming session. Setting Label ID Characters by Symbology
SET-------------------------------------
Code 39
---------
PharmaCode 39
---------
Code 128
---------
UCC/EAN 128
---------
SR60 Scanner Programmer’s Reference Manual
63
Page 78
Chapter 3, Configuring Label Transmit Settings
Interleaved 2 of 5 ---------
64
Codabar
---------
UPC-A
---------
UPC-A (2 digit add-ons)
---------
UPC-A (with 5 digit add-ons)
---------
UPC-A (with C128 add-ons)
---------
UPC-E
---------
SR60 Scanner Programmer’s Reference Manual
Page 79
Chapter 3, Configuring Label Transmit Settings UPC-E (with 2 digit add-ons)
---------
UPC-E (with 5 digit add-ons)
---------
UPC-E (with C128 add-ons)
---------
EAN-13
---------
EAN-13 (with 2 digit add-ons)
---------
EAN-13 (with 5 digit add-ons)
---------
EAN-13 (with C128 add-ons)
---------
SR60 Scanner Programmer’s Reference Manual
65
Page 80
Chapter 3, Configuring Label Transmit Settings
66
EAN-8
---------
EAN-8 (with 2 digit add-ons)
---------
EAN-8 (with 5 digit add-ons)
---------
EAN-8 (C128 add-ons)
---------
Code 93
---------
Standard 2 of 5
---------
MSI/Plessey
---------
SR60 Scanner Programmer’s Reference Manual
Page 81
Chapter 3, Configuring Label Transmit Settings
END------------------------------------
Setting a Single-Character Label ID The scanner does not transmit a label ID character if its hex value is set to zero. If you need a Label ID that contains only a single character, you can set a single-character label ID. To set a single-character label ID 1 Using the ASCII table on page 164, identify the ASCII character and the corresponding hex code for the singlecharacter label ID. For example, suppose you want to change the Label ID for EAN-8 from the default setting FF to the single character 8. The ASCII chart shows that ASCII 8 equals 38 hex. 2 Scan the SET bar code on page 63. 3 Using the bar codes in “Selecting the Symbology” on page 63, scan the bar code representing the symbology whose Label ID you want to change. For this example, you would scan the EAN-8 bar code. 4 Using the list of bar codes that starts on page 160, scan the two digits corresponding to the hex value you chose in Step 1. 5 Scan the 0 digit twice to disable transmission of a second character. For this example, you would scan 3, 8, 0, and 0. Note: Successful programming requires four digits for the label ID. Note: If you make a mistake or lose your place while setting this option, scan the END bar code to exit Programming mode. The scanner sounds a two-beep error tone to indicate that programming was incomplete, and the setting remains as it was before entering Programming mode. SR60 Scanner Programmer’s Reference Manual
67
Page 82
Chapter 3, Configuring Label Transmit Settings
6 Scan the END bar code.
Disabling a Symbology-Specific Label ID To disable a symbology-specific label ID, you follow the steps in the “To set a single-character label ID” procedure on page 67, except you must scan four zeros in Step 5.
68
SR60 Scanner Programmer’s Reference Manual