Page 69
Chapter 3, Configuring Label Transmit Settings
4 Scan these bar codes. End
$
+
$
Code 39 Min Length = 2 g
To clear the prefix and suffix 1 Scan this bar code. Start
$
%
/
2 Scan this bar code to clear the Preamble (prefix) and Postamble (suffix). Clear Ambles
Q
0
0
3 Scan this bar code. End
$
+
$
SR60 Scanner Programmer’s Reference Manual
55
Page 70
Chapter 3, Configuring Label Transmit Settings
Setting an EOM for a USB Interface For the USB interface, the global character that is added at the end of every scan is an End of Message (EOM) character, not a Postamble (suffix). However, if you use an EOM without a suffix, the EOM acts as the suffix. The next procedure describes how to set an EOM for a USB interface. If the EOM you want to set is not in Step 2, set the EOM to None and set a suffix. For help, see “Setting a Prefix or Suffix for a USB Interface” on page 54. To set an EOM for a USB interface 1 Scan this bar code. Start
$
%
/
2 Scan one of these EOM bar codes. The default setting is Return. EOM=Enter
D
P
5 EOM=Field Exit
D
P
3
EOM=CR/LF
D
56
P
6
SR60 Scanner Programmer’s Reference Manual
Page 71
Chapter 3, Configuring Label Transmit Settings EOM=Tab +
D
P
1
EOM=Return
D
P
7 EOM=LF
D
P
2
EOM=Field Advance
D
P
4 EOM=None
D
P
0
3 Scan this bar code. End
$
+
$
SR60 Scanner Programmer’s Reference Manual
57
Page 72
Chapter 3, Configuring Label Transmit Settings
Setting a Prefix or Suffix for a Multi or Decoded Interface Use this procedure to set a prefix or suffix that has only one character. Do not use this procedure if you have a USB interface. For a USB interface, see “Setting a Prefix or Suffix for a USB Interface” on page 54. To set a prefix or suffix that has only one character 1 Using the ASCII table on page 164, identify the ASCII character and the corresponding hex code for the singlecharacter prefix or suffix. For example, suppose you want to use the Space (SP) character. The ASCII charts shows that SP equals 20 hex. 2 Scan the SET bar code on page 59. 3 Scan the Set Prefix or Set Suffix bar code. 4 Using the list of bar codes that starts on page 160, scan the two digits corresponding to the hex value you chose in Step 1. 5 Scan the 0 digit twice to disable the transmission of a second character. 6 For this example, you would scan 2, 0, 0, and 0. Note: Successful programming requires four digits for the label ID. Note: If you make a mistake or lose your place while setting this option, scan the END bar code to exit Programming mode. The scanner sounds a two-beep error tone to indicate that programming was incomplete, and the setting remains as it was before entering Programming mode. 7 Scan the END bar code.
58
SR60 Scanner Programmer’s Reference Manual
Page 73
Chapter 3, Configuring Label Transmit Settings
Setting a Single Character Prefix/Suffix
SET-------------------------------------
Set Prefix
---------
Set Suffix
---------
END------------------------------------
Setting a Label ID Setting the Label ID feature can be a complex task that requires multiple steps to enable all necessary options.
About Symbology-Specific Label Identifiers Symbology-specific label identifiers consist of one or two ASCII characters that can precede or follow the bar code label data as it is transmitted to the host. The host may use these characters as a means of distinguishing between symbologies.
SR60 Scanner Programmer’s Reference Manual
59
Page 74
Chapter 3, Configuring Label Transmit Settings
Industry standards have been established for symbology-specific label identifiers, which are listed in the next table. Most scanners have factory default identifiers preset to these standards. Industry Standard Label Identifiers (Prefixes)
60
Symbology
Identifier (ID)
UPC-A UPC-E EAN-8 EAN-13 UPC-A (with 2 add-ons) UPC-A (with 5 add-ons) UPC-A (with 8 add-ons) UPC-E (with 2 add-ons) UPC-E (with 5 add-ons) UPC-E (with 8 add-ons) EAN-8 (with 2 add-ons) EAN-8 (with 5 add-ons) EAN-8 (with 8 add-ons) EAN-13 (with 2 add-ons) EAN-13 (with 5 add-ons) EAN-13 (with 8 add-ons) Code 39 PharmaCode Codabar Interleaved 2 of 5 Standard 2 of 5 Code 93 Code 128 UPC/EAN 128 MSI/Plessey
A E FF F A A A E E E FF FF FF F F F * A % i i & # None @
SR60 Scanner Programmer’s Reference Manual
Page 75
Chapter 3, Configuring Label Transmit Settings
Setting the Label ID Location You can specify the location where Label ID characters are to be placed in relation to scanned label data. The location you choose will be applied universally to all symbologies; you cannot specify a symbology-specific label ID location. The locations include: • None (for example, prefix, label data, suffix) • Prefix (for example, prefix, label ID, label data, suffix) • Suffix (for example, prefix, label data, label ID, suffix) To set the label ID location 1 Scan the SET bar code. 2 Scan the bar code for the location you chose. 3 Scan the END bar code. Setting Label ID Location
SET-------------------------------------
Label ID = None
---------
Position Label ID as Prefix
---------
SR60 Scanner Programmer’s Reference Manual
61
Page 76
Chapter 3, Configuring Label Transmit Settings
Position Label ID as Suffix
---------
END------------------------------------
Setting a Symbology-Specific Label ID You can configure a label ID for each symbology. To set a symbology-specific label ID 1 Using the ASCII table on page 164, identify the ASCII character(s) and the corresponding hex code(s) for the ASCII characters you plan to use as the label ID. For example, suppose you want to change the label ID for UPC-A to A1. The ASCII chart shows that A equals 41 hex and 1 equals 31 hex. 2 Scan the SET bar code on page 63. 3 Using the bar codes in “Selecting the Symbology” on page 63, scan the bar code representing the symbology whose Label ID you want to change. For this example, you would scan the UPC-A symbology bar code. 4 Using the list of bar codes that starts on page 160, scan the four digits corresponding to the hex values you chose in Step 1. For this example, you would scan 4, 1, 3, and 1. Note: Successful programming requires four digits for the label ID.
62
SR60 Scanner Programmer’s Reference Manual