The text of a manual · part 8 of 22
SR60 Scanner Programmer's Reference Manual: Chapter 3 - Configuring Label Transmit Settings, pages 61 to 68
Pages 61 to 68 of 194, from SR60 Scanner Programmer's Reference Manual
The original document is the PDF (2.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec SR60
Page 61
Label Transmit 3 Configuring Settings
This chapter contains the programming bar codes for configuring the optional prefix, suffix, and label ID which may be sent in addition to bar code data if your SR60 scanner is configured for the RS-232 or Keyboard Wedge interface. You will find these sections in this chapter: • When to Configure Label Transmit Settings • How to Use the Prefix, Suffix, and Label ID • Setting Global Prefixes and Suffixes • Setting a Prefix or Suffix • Setting a Label ID
SR60 Scanner Programmer’s Reference Manual
47
Page 62
Chapter 3, Configuring Label Transmit Settings
When to Configure Label Transmit Settings If you need to send information in addition to bar code label data, you can configure the scanner to transmit: • global prefixes (or preambles). • global suffixes (or postambles). • symbology-specific identifier characters (or label IDs). You may configure these Label Transmit settings only if your SR60 scanner has been configured to use either the RS-232 or Keyboard Wedge interface.
How to Use the Prefix, Suffix, and Label ID The following table shows how you can use the prefix, suffix, and label ID characters. Note: Using these features requires a thorough understanding of your specific system requirements. For help, contact Intermec Product Support. Label ID Global Prefix as Prefix
Label Data
Label ID as Suffix
Resulting Label Global Suffix Format
1st Char
2nd Char
1st 2nd Char Char Examples
1st 2nd 1st Char Char Char
2nd Char
Examples
00 50 00 50 00 50 00 50 00 50 00 50
00 51 00 51 00 51 00 51 00 00 00 51
None None 46 41 None None None None 45 45 None None
None None None None 25 25 None None None None 46 46
00 000 00 00 00 00 57 57 00 57 57 57
0998875 PQ0011223344 FF00210126 PQA210126 $99.95% PQ998875E 10123456789SW PQCode39TestSW ECode128S PFF09988875SW 0998875FFSW PQ0011223344FSW
46 00a
00a 46
0998875 0011223344 00210126 00210126 $99.95 998875 101234567891 Code39Test Code128 0998875 0998875 0011223344
00a 00a
46 00a
00 000 00 00 00 00 53 53 53 53 53 53 a. The 00 indicates no second character.
48
SR60 Scanner Programmer’s Reference Manual
Page 63
Chapter 3, Configuring Label Transmit Settings
Note: In the Global Prefix and the Global Suffix columns, 00 indicates no character.
Setting Global Prefixes and Suffixes This section describes how to set global prefixes and suffixes. Do not use these procedures if you have a USB interface. For a USB interface, see “Setting a Prefix or Suffix for a USB Interface” on page 54.
Setting Global Prefixes You may add one or two prefix characters to the standard label format. To add more than two prefix characters, contact Intermec Product Support for Full Label Edit (FLE) options. To set global prefixes 1 Identify your specific system requirements. 2 Using the ASCII table on page 164, identify the ASCII character(s) and the corresponding hex code(s) for the prefix. For example, suppose you want to send the two prefix characters STX (start transmit) and SP (Space). The ASCII chart shows that STX equals 02 hex and SP equals 20 hex. 3 Scan the SET bar code on page 50. 4 Scan the Set Prefix bar code. 5 Using the list of bar codes that starts on page 160, scan the four digits corresponding to the hex values you chose in Step 2. For this example, you would scan 0, 2, 2, and 0. Note: Successful programming requires four digits for the label ID.
SR60 Scanner Programmer’s Reference Manual
49
Page 64
Chapter 3, Configuring Label Transmit Settings
Note: If you make a mistake or lose your place while setting this option, scan the END bar code to exit Programming mode. The scanner sounds a two-beep error tone to indicate that programming was incomplete, and the setting remains as it was before entering Programming mode. 6 Scan the END bar code. You have added a two-character prefix to all bar code data, regardless of label symbology. The prefix will be added to the label data before it is sent to the host. Setting Global Prefix(es)
SET-------------------------------------
Set Prefix
---------
Use the ASCII chart on 68 to identify the ASCII character(s) and the corresponding hex code(s) for the prefix. Then use the bar codes on page 160 to scan the four digits corresponding to the hex values. END------------------------------------
Setting Global Suffixes You may add one or two suffix characters to the standard label format. To add more than two suffix characters, contact Intermec Product Support for Full Label Edit (FLE) options.
50
SR60 Scanner Programmer’s Reference Manual
Page 65
Chapter 3, Configuring Label Transmit Settings
To set global suffixes 1 Identify your specific system requirements. 2 Using the ASCII table on page 164, identify the ASCII character(s) and the corresponding hex code(s) for the ASCII characters you plan to use as suffixes. 3 Scan the SET bar code below. 4 Scan the Set Suffix bar code. 5 Using the list of bar codes that starts on page 160, scan the four digits corresponding to the hex values you chose in Step 2. For this example, you would scan 0, A, 0, and D. Note: Successful programming requires four digits for the label ID. Note: If you make a mistake or lose your place while setting this option, scan the END bar code to exit Programming mode. The scanner sounds a two-beep error tone to indicate that programming was incomplete, and the setting remains as it was before entering Programming mode. 6 Scan the END bar code. You have added a two-character suffix to all bar code data, regardless of label symbology, that will be added to the label data before it is sent to the host. Setting Global Suffix(es)
SET-------------------------------------
SR60 Scanner Programmer’s Reference Manual
51
Page 66
Chapter 3, Configuring Label Transmit Settings
Set Suffix
---------
Use the ASCII table on page 164 to identify the ASCII character(s) and the corresponding hex code(s) for the suffix. Then use the bar codes on page 160 to scan the four digits corresponding to the hex values.
END------------------------------------
Disabling a Global Prefix or Suffix You can disable a global prefix or suffix. To disable global prefix or suffix characters 1 Scan the SET bar code on this page. 2 Scan the Set Prefix or Set Suffix bar code. 3 Scan the 0 digit four times to disable the prefix or suffix characters. 4 Scan the END bar code. Disabling Global Prefix/Suffix Characters
SET-------------------------------------
Set Prefix
52
---------
SR60 Scanner Programmer’s Reference Manual
Page 67
Chapter 3, Configuring Label Transmit Settings
Set Suffix
---------
0
---------
END------------------------------------
Setting a Prefix or Suffix The method you use to set a prefix or suffix depends on your scanner interface: • USB Interface • Wand Emulation, Keyboard Wedge, RS-232, or Decoded Interface The scanner does not transmit a prefix or suffix character if its hex value is set to zero. Note: For the USB interface, the global character that is added at the end of every scan is an End of Message (EOM) character, not a Postamble (suffix). For help, see “Setting an EOM for a USB Interface” on page 56.
SR60 Scanner Programmer’s Reference Manual
53
Page 68
Chapter 3, Configuring Label Transmit Settings
Setting a Prefix or Suffix for a USB Interface Use this procedure to set a prefix or suffix. To set a prefix or suffix for a USB interface 1 Scan these bar codes. Code 39 Min Length = 1 g
Start
$
%
/
Lower Case = Enable
D
H
I
EOM = None
D
P
0
2 Scan the Preamble (prefix) or the Postamble (suffix) bar code. Preamble
Q
0
1
Postamble
Q
0
2
3 Using the Full ASCII Chart on page 165, scan up to 19 characters. Use the Null character to clear the prefix or suffix.
54
SR60 Scanner Programmer’s Reference Manual