The text of a manual · part 14 of 22
SR60 Scanner Programmer's Reference Manual: Chapter 4 - Enabling and Configuring Symbologies, pages 113 to 122
Pages 113 to 122 of 194, from SR60 Scanner Programmer's Reference Manual
The original document is the PDF (2.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec SR60
Page 113
Chapter 4, Enabling and Configuring Symbologies Gap Check Enable
---------
Disable
---------
END------------------------------------
Label Length Format The following two sections explain how to set the Codabar Label Length Format to either the Variable Length or Fixed Length Format.
Variable Length Format You can set the Codabar symbology to Variable Length Format. To set the Codabar symbology to Variable Length Format 1 Identify the minimum length setting you want to make. The selectable range is 03 to 50 characters. Note: For this symbology, the scanner decodes up to 50 characters, but the actual length read varies depending upon the interface type, bar code physical size, and print quality. 2 Scan the SET bar code. 3 Scan the Enable Variable Length Format bar code. 4 Scan the Set Minimum Label bar code. 5 Using the Digits bar codes on page 102, scan the digits to set the minimum label length you identified in Step 1.
SR60 Scanner Programmer’s Reference Manual
99
Page 114
Chapter 4, Enabling and Configuring Symbologies
Note: To set a label length less than ten, you must scan a zero digit first and then the length digit (such as 04, 06, or 08). 6 Scan the END bar code. Variable Length Format SET------------------------------------
Enable Variable Length Format
---------
Set Minimum Label Length
---------
END------------------------------------
Fixed Length Format The scanner offers the option of requiring Codabar labels to have one or two fixed lengths in the Fixed Label Format. To set Codabar symbology to Fixed Length Format 1 Identify the fixed length settings you want to make. 2 Scan the SET bar code. 3 Scan the Enable Fixed Length Format bar code. 4 Scan the Set First Fixed Length bar code. 5 Using the Digits bar codes on page 102, scan the digits to set the first fixed label length you identified in Step 1.
100
SR60 Scanner Programmer’s Reference Manual
Page 115
Chapter 4, Enabling and Configuring Symbologies
Note: To set a label length less than ten, you must scan a zero digit first and then the length digit (such as 04, 06, or 08). • If you need to set a second fixed length, continue with Step 6. • If you do not need to set a second fixed length, scan the No Second Fixed Length bar code and skip to Step 8. 6 Scan the Set Second Fixed Length bar code. 7 Using the Digits bar codes on page 102, scan the digits to set the second fixed label length you identified in Step 1. Note: To set a label length less than ten, you must scan a zero digit first and then the length digit (such as 04, 06, or 08). 8 Scan the END bar code. Fixed Length Format
SET------------------------------------
Enable Fixed Length Format
---------
Set First Fixed Length
---------
Set Second Fixed Length
---------
SR60 Scanner Programmer’s Reference Manual
101
Page 116
Chapter 4, Enabling and Configuring Symbologies
No Second Fixed Length
---------
END------------------------------------
Digits
102
0
---------
1
---------
2
---------
3
---------
4
---------
SR60 Scanner Programmer’s Reference Manual
Page 117
Chapter 4, Enabling and Configuring Symbologies
5
---------
6
---------
7
---------
8
---------
9
---------
Start/Stop Characters SET------------------------------------
Match Not Required
---------
SR60 Scanner Programmer’s Reference Manual
103
Page 118
Chapter 4, Enabling and Configuring Symbologies
Match Required
---------
Don’t Transmit
---------
Transmit (Requires a format. For help, see the next Note.) ---------
Format = ABCD/ TN*E
---------
Format = abcd/ tn*e
---------
Format = ABCD/ ABCD
---------
Format = abcd/ abcd
---------
END------------------------------------
Note: If you choose Transmit, you must also choose one of these data formats: ABCD/TN*E, abcd/tn*e, ABCD/ABCD, or abcd/ abcd by scanning the appropriate bar code. 104
SR60 Scanner Programmer’s Reference Manual
Page 119
Chapter 4, Enabling and Configuring Symbologies
Read Verification Scan the following bar codes to set the number of reads to verify Codabar symbology. Note: The more times the scanner is required to read and compare the bar code data, the longer the scanner takes to validate and transmit a label.
SET------------------------------------
Set to One Read
---------
Set to Two Reads
---------
Set to Three Reads ---------
Set to Four Reads ---------
END------------------------------------
SR60 Scanner Programmer’s Reference Manual
105
Page 120
Chapter 4, Enabling and Configuring Symbologies
UPC/EAN Options This section describes the UPC/EAN options and contains the programming bar codes you can use to configure those options.
About UPC/EAN Options The UPC/EAN symbologies have the following programmable features: • Data Format Settings • UPC/EAN Expansion • UPC/EAN Add-ons • Price/Weight Check Digit • Read Verification
Data Format Settings UPC/EAN Data Format Settings provides options for transmitting check digits or Number System Digits (NSD).
UPC/EAN Expansion Expand UPC-A to EAN-13 adds a leading zero to a UPC-A label which expands the label to the EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13. Expand UPC-E to UPC-A expands UPC-E labels to UPC-A data format. Selecting this feature also changes the symbology ID to match those required for UPC-A. Expand EAN-8 to EAN-13 adds five zeros in front of an EAN-8 label. Data is sent in EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN13. Expand UPC-E to EAN-13 expands UPC-E labels to EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13.
UPC/EAN Add-ons UPC-A or UPC-E and EAN-8 or EAN-13 Two and Five Digit Add-ons filters: • Required means UPC/EAN bar codes must have add-ons or label will not be read. 106
SR60 Scanner Programmer’s Reference Manual
Page 121
Chapter 4, Enabling and Configuring Symbologies
• Optional means scanner reads UPC/EAN bar codes with or without add-ons. • Disable directs the scanner not to recognize or read add-on portions of UPC/EAN labels, but to read the main body of the label.
Price/Weight Check Digit Price/Weight Check Digit provides options for enabling price/ weight check digits. The feature includes selections for domestic four or five digit, and European four or five digit, as well as the option to disable the price/weight check.
Read Verification Read Verification is the number of times the scanner is required to read the bar code data before sending the label data to the host.
Configuring the UPC/EAN Options Use the following bar codes to configure the UPC/EAN options.
UPC Data Format Settings These settings affect UPC data format. Scan the following bar codes to send or not send the check digit and the Number System Digit (NSD). Note: The NSD settings operate only with RS-232 and Keyboard Wedge interfaces. The NSD is the character that precedes the UPC bar code. Common NSDs are: • 0 is used for regular UPC-A bar codes. • 2 is used for random weight items such as meat and produce. • 3 is used for the drug and health items. • 4 is used for in-store non-food items. • 5 is used for coupons.
The Location of the NSD: This UPC-A bar code contains an NSD of 0.
SR60 Scanner Programmer’s Reference Manual
107
Page 122
Chapter 4, Enabling and Configuring Symbologies
SET------------------------------------
UPC-A Send Check Digit ---------
Don’t Send Check Digit
---------
Send NSD
---------
Don’t Send NSD
---------
UPC-E Send Check Digit ---------
Don’t Send Check Digit
108
---------
SR60 Scanner Programmer’s Reference Manual