Page 123

Chapter 4, Enabling and Configuring Symbologies

Send NSD

---------

Don’t Send NSD

---------

END------------------------------------

Note: If UPC-E is expanded to UPC-A, the transmission of the check digit and the NSD is determined by the UPC-A settings on this page.

EAN Data Format Settings These settings affect EAN data format.

SET------------------------------------

EAN-13 Send Check Digit ---------

Don’t Send Check Digit

---------

SR60 Scanner Programmer’s Reference Manual

109

Page 124

Chapter 4, Enabling and Configuring Symbologies

Send NSD

---------

Don’t Send NSD

---------

EAN-8 Send Check Digit ---------

Don’t Send Check Digit

---------

END------------------------------------

UPC/EAN Expansion Scan the following bar codes to activate UPC/EAN Expansion: • Expand UPC-A to EAN-13 • Expand UPC-E to UPC-A • Expand EAN-8 to EAN-13 • Expand UPC-E to EAN-13

110

SR60 Scanner Programmer’s Reference Manual

Page 125

Chapter 4, Enabling and Configuring Symbologies

Note: If you choose Expand for any of the following features, the transmission of the prefix, suffix, check digit, and NSD will be controlled by your selections for the symbology expanded to rather than the symbology expanded from. For example, if you expand OPC-E to UPC-A, the settings for UPC-A determine how the scanner sends the bar code contents.

SET------------------------------------

UPC-A to EAN-13 Expansion Expand

---------

Don’t Expand

---------

UPC-E to UPC-A Expansion Expand

---------

Don’t Expand

---------

EAN-8 to EAN-13 Expansion Expand

---------

SR60 Scanner Programmer’s Reference Manual

111

Page 126

Chapter 4, Enabling and Configuring Symbologies

Don’t Expand

---------

UPC-E to EAN-13 Expansion Expand

---------

Don’t Expand

---------

END------------------------------------

UPC/EAN Add-ons There are many ways to configure the scanner to handle add-ons. The scanner uses four filters that can be specified to define how add-ons are handled. The following is true for each filter: • Each add-on type can be disabled, required or optional. • Any combination of the four UPC/EAN symbologies can be affected. • The 2-digit, 5-digit and C128 add-ons can be individually configured. • The leading digits of the base labels affected can be specified. Note: These settings represent only a small portion of the options available for this feature. For help with advanced add-on settings, contact Intermec Product Support.

112

SR60 Scanner Programmer’s Reference Manual

Page 127

Chapter 4, Enabling and Configuring Symbologies

The following add-on filters for UPC/EAN are supported: • Add-ons Required means that UPC/EAN labels must contain a 2-digit, 5-digit, or C128 add-on segment in order for the scanner to recognize or decode them. • Add-ons Optional directs the scanner to recognize UPC/EAN bar codes with or without P2, P5, or C128 2-digit add-on segments. • Disable Add-ons means the scanner will not recognize or decode any add-on segment of UPC/EAN labels, but will read and decode the standard UPC/EAN portion of the label. Note: Due to the structure of add-on codes, selecting the optional setting makes it impossible to ensure that the scanner will always read the add-on portion of the label. Intermec makes no guarantee, either written or implied, that scanners with optional add-on decoding enabled will perform with the speed and accuracy required for any given application. The following bar codes affect all four UPC/EAN symbologies, and are applied to all labels regardless of the leading digits of the base label.

SET------------------------------------

Add-ons Required ---------

Add-ons Optional ---------

SR60 Scanner Programmer’s Reference Manual

113

Page 128

Chapter 4, Enabling and Configuring Symbologies

Disable Add-ons

---------

END------------------------------------

Custom Add-ons A wide array of add-on options are available to streamline your installation to its best advantage. For help with custom add-ons, contact Intermec Product Support.

Price/Weight Check Digit The Price/Weight Check Digit selections allow you to specify whether the scanner should calculate an extra check digit based on a four or five-digit price/weight block and compare it with the price/weight check digit contained in the bar code. If the calculated check digit does not match the value of the check digit contained in the bar code, the label will be rejected as invalid. Use the following bar codes to select domestic four or five digit, select European four or five digit, or disable the price/weight check.

SET------------------------------------

Disable Price/ Weight Check Digit ---------

Enable 4-Digit Check Digit

114

---------

SR60 Scanner Programmer’s Reference Manual

Page 129

Chapter 4, Enabling and Configuring Symbologies

Enable 5-Digit

---------

Enable Euro 4Digit

---------

Enable Euro 5Digit

---------

END------------------------------------

Read Verification You can set the number of minimum reads required to verify UPC/EAN symbologies. To set the number of minimum reads 1 Scan the SET bar code. 2 Scan a bar code to select which symbology to verify. 3 Scan the bar code on page 116 that represents the number of times you wish a bar codes label of that symbology type to be read before transmission to the host from the list. 4 Repeat Steps 2 and 3 until read verification has been modified for each symbology you enabled. 5 Scan the END bar code.

SR60 Scanner Programmer’s Reference Manual

115

Page 130

Chapter 4, Enabling and Configuring Symbologies

Read Verification

SET-------------------------------------

Verify UPC-A

---------

Verify UPC-E

---------

Verify EAN-13

---------

Verify EAN-8

---------

Verify Instore Label

---------

Number of Reads to Verify

One Read

116

---------

SR60 Scanner Programmer’s Reference Manual

Page 131

Chapter 4, Enabling and Configuring Symbologies

Two Reads

---------

Three Reads

---------

Four Reads

---------

END------------------------------------

Code 93 Options This section describes the Code 93 options and contains the programming bar codes you can use to configure those options.

About Code 93 Options The Code 93 symbology has the following programmable features: • Minimum Label Length • Read Verification

Minimum Label Length Minimum Label Length sets the minimum label length required for Code 93 symbology. This feature causes the scanner to ignore small label segments, reducing the possibility that a portion of a good label is incorrectly seen as an entire label.

Read Verification Read Verification is the number of times the scanner is required to read the bar code data before sending the label data to the host.

SR60 Scanner Programmer’s Reference Manual

117

Page 132

Chapter 4, Enabling and Configuring Symbologies

Configuring the Code 93 Options Scan the following bar codes to configure the Code 93 options.

Minimum Label Length You can set the Minimum Label Length. Note: For this symbology, the scanner decodes up to 50 characters, but the actual length read varies depending upon interface type, bar code physical size, and print quality. The IBM POS interface is limited to 32 character labels. Code 93 bar codes containing one or more shift characters can also limit the amount of characters that are decoded; in these circumstances, the scanner decodes at least 39 data characters. To set the Minimum Label Length 1 Identify the minimum length setting you want to make. The selectable range is 01 to 50 characters. 2 Scan the SET bar code. 3 Scan the Set Minimum Label Length bar code. 4 Using the Digits bar codes on page 119, scan the digits to set the minimum label length you identified in Step 1. The range is 01 to 50 characters. Note: To set a label length less than ten, you must scan a zero digit first and then the length digit (such as 04, 06, or 08). 5 Scan the END bar code.

SET-------------------------------------

Set Minimum Label Length

118

---------

SR60 Scanner Programmer’s Reference Manual