For the Intermec SR60

Page 133

Chapter 4, Enabling and Configuring Symbologies

Use the Digits bar codes to specify the two-digit minimum length value you identified in Step 1. END-----------------------------------

Digits

0

---------

1

---------

2

---------

3

---------

4

---------

5

---------

SR60 Scanner Programmer’s Reference Manual

119

Page 134

Chapter 4, Enabling and Configuring Symbologies

6

---------

7

---------

8

---------

9

---------

Read Verification Scan the following bar codes to set the number of reads to verify Code 93 symbology. Note: The more times the scanner is required to read and compare the bar code data, the longer the scanner takes to validate and transmit a label.

SET-------------------------------------

Set to One Read

120

---------

SR60 Scanner Programmer’s Reference Manual

Page 135

Chapter 4, Enabling and Configuring Symbologies

Set to Two Reads

---------

Set to Three Reads ---------

Set to Four Reads ---------

END------------------------------------

Standard 2 of 5/IATA Options This section describes the Code 39 options and contains the programming bar codes you can use to configure those options.

About Standard 2 of 5/IATA Options The Standard 2 of 5/IATA symbologies have the following programmable features: • Check Digit • Label Length Format • Read Verification

Check Digit Check Digit calculates the check digit to verify that the check digit contained in the bar code label is correct. If you enable this feature, your bar codes must contain a check digit.

SR60 Scanner Programmer’s Reference Manual

121

Page 136

Chapter 4, Enabling and Configuring Symbologies

If the check digit is not calculated, the digit will be sent regardless of settings for transmit or don’t transmit. For example, if you choose to transmit check digit, but not calculate it, the scanner sends the check digit encoded in the bar code without verifying its accuracy.

Label Length Format Label Length Format lets you choose either variable length or fixed length formats. For best performance, you should use the Fixed Length settings when your application requires only one or two label lengths. Note: For this symbology, the scanner decodes up to 50 characters, but the actual length read varies depending upon the interface type, bar code physical size, and print quality. • The Enable Variable Length Format bar code on page 124 directs the scanner to read all labels from the minimum label length to 50. If you select variable length format, there is one more bar code label to scan: • The Set Minimum Label Length bar code on page 124 selects the minimum label length that the scanner will recognize. The minimum label length for this symbology must be between 01 and 50. Set the Minimum Length as high as your application allows. • The Enable Fixed Length Format bar code on page 126 directs the scanner to read only one or two label lengths. If you select fixed length format, there are three bar code labels for programming your scanner to read either one or two fixed lengths. The labels are: • The Set First Fixed Length bar code on page 126 instructs the scanner that the next two programming labels scanned will define the first fixed label length. This setting must be between 01 and 50 characters. • The Set Second Fixed Length bar code on page 126 instructs the scanner that the next two programming labels scanned will define the second fixed label length. This setting must be between 01 and 50 characters.

122

SR60 Scanner Programmer’s Reference Manual

Page 137

Chapter 4, Enabling and Configuring Symbologies

• The No Second Fixed Length bar code on page 126 configures the scanner to recognize only the first fixed length.

Read Verification Read Verification is the number of times the scanner is required to read the bar code data before sending the label data to the host.

Configuring the Standard 2 of 5/IATA Options Scan the following bar codes to configure the Standard 2 of 5/ IATA symbology options. Check Digit SET-------------------------------------

Don’t Calculate

---------

Calculate

---------

Don’t Transmit

---------

Transmit

---------

END------------------------------------

SR60 Scanner Programmer’s Reference Manual

123

Page 138

Chapter 4, Enabling and Configuring Symbologies

Label Length Format The next two sections let you set the Standard 2 of 5/IATA label length format to either Variable Length or Fixed Length format.

Variable Length Format You can set the Standard 2 of 5/IATA symbology to read Variable Length Format. Note: For this symbology, the scanner decodes up to 50 characters, but the actual length read varies depending upon the interface type, bar code physical size, and print quality. To set Standard 2 of 5/IATA symbology to read Variable Length Format 1 Identify the minimum length setting you want to make. The selectable range is 02 to 50 characters. 2 Scan the SET bar code. 3 Scan the Enable Variable Length Format bar code. 4 Scan the Set Minimum Label Length bar code. 5 Using the Digits bar codes on page 127, scan the digits to set the minimum label length you identified in Step 1. Note: To set a label length less than ten, you must scan a zero digit first and then the length digit (such as 04, 06, or 08). 6 Scan the END bar code. Variable Length Format SET-------------------------------------

Enable Variable Length Format ---------

Set Minimum Label Length ---------

124

SR60 Scanner Programmer’s Reference Manual

Page 139

Chapter 4, Enabling and Configuring Symbologies

END------------------------------------

Fixed Length Format All interfaces that are shipped with the standard factory configuration are set to read variable length labels. If you switch from variable length to fixed length format, the default fixed labels are 14 characters and 8 digits. To change the defaults for the Standard 2 of 5/IATA symbology 1 Identify the fixed length settings you want to make. 2 Scan the SET bar code. 3 Scan the Enable Fixed Length Format bar code. 4 Scan the Set First Fixed Length bar code. 5 Using the Digits bar codes on page 127, scan the digits to set the first fixed label length you identified in Step 1. Note: To set a label length less than ten, you must scan a zero digit first and then the length digit (such as 04, 06, or 08). • If you need to set a second fixed length, continue with Step 6. • If you do not need to set a second fixed length, scan the No Second Fixed Length bar code and skip to Step 8. 6 Scan the Set Second Fixed Length bar code. 7 Using the Digits bar codes on page 127, scan the digits to set the second fixed label length you identified in Step 1. Note: To set a label length less than ten, you must scan a zero digit first and then the length digit (such as 04, 06, or 08). 8 Scan the END bar code.

SR60 Scanner Programmer’s Reference Manual

125

Page 140

Chapter 4, Enabling and Configuring Symbologies Fixed Length Format SET-------------------------------------

Enable Fixed Length Format

---------

Set First Fixed Length

---------

Set Second Fixed Length ---------

No Second Fixed Length

---------

END------------------------------------

126

SR60 Scanner Programmer’s Reference Manual

Page 141 read from a scan by OCR; it may hold reading errors

Chapter 4, Enabling and Configuring Symbologies

Digits : _ | | | | | | | BS We _ | | HK | |

_ | | | | ; _ lM | ° _ | | HI |

SR60 Scanner Programmer's Reference Manual 127 co)

Page 142

Chapter 4, Enabling and Configuring Symbologies

7

---------

8

---------

9

---------

Read Verification Scan the following bar codes to set the number of reads to verify Standard 2 of 5/IATA symbologies. Note: The more times the scanner is required to read and compare the bar code data, the longer the scanner takes to validate and transmit a label.

SET-------------------------------------

128

Set to One Read

---------

Set to Two Reads

---------

SR60 Scanner Programmer’s Reference Manual