Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 17 of 22

SR60 Scanner Programmer's Reference Manual: Chapter 4 - Enabling and Configuring Symbologies, pages 143 to 152

Pages 143 to 152 of 194, from SR60 Scanner Programmer's Reference Manual

The original document is the PDF (2.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec SR60

Page 143

Chapter 4, Enabling and Configuring Symbologies

Set to Three Reads ---------

Set to Four Reads ---------

END------------------------------------

IATA Options IATA is a special symbology subset of Standard 2 of 5. Enabling IATA selects this custom code as the active Standard 2 of 5 symbology. When IATA is enabled, Standard 2 of 5 labels are not read. Scan the following bar codes to enable or disable IATA. SET-------------------------------------

Enable

---------

Disable

---------

SR60 Scanner Programmer’s Reference Manual

129

Page 144

Chapter 4, Enabling and Configuring Symbologies

END-----------------------------------

MSI/Plessey Options This section describes the MSI/Plessey options and contains the programming bar codes you can use to configure those options.

About MSI/Plessey Options The MSI/Plessey symbology has the following programmable features: • Check Digit • Label Length Format • Read Verification

Check Digit Check Digit calculates the check digit(s) to verify the labels contents have been read correctly. If you enable this feature, your bar codes must include one or two check digits. You may also choose to transmit or not transmit the check digit(s). • The Calculate bar code on page 132 enables calculation of the check digits. The Don’t Calculate bar code disables calculation. • The Transmit bar code on page 132 enables transmission of MSI/Plessey check digit(s). The Don’t Transmit bar code disables transmission. • The One Check Digit bar code and the Two Check Digits bar code on page 132 specifies either one or two check digits.

Label Length Format Label length format permits the selection between variable length or fixed length formats. For best performance, Intermec recommends that you use the Fixed Length settings when your application requires only one or two label lengths. • The Enable Variable Length Format bar code on page 133 directs the scanner to read all labels from the minimum label

130

SR60 Scanner Programmer’s Reference Manual

Page 145

Chapter 4, Enabling and Configuring Symbologies length to 16. If you select variable length format, there is one more bar code label to scan: • The Set Minimum Label Length bar code on page 133 selects the minimum label length that the scanner will recognize. The minimum label length for this symbology must be between 04 and 16. Set the Minimum Length as high as your application allows. • The Enable Fixed Length Format bar code on page 134 directs the scanner to read only one or two label lengths. If you select fixed length format, there are three bar code labels for programming your scanner to read either one or two fixed lengths. The labels are: • The Set First Fixed Length bar code on page 135 instructs the scanner that the next two programming labels scanned will define the first fixed label length. This setting must be between 04 and 16 characters. • The Set Second Fixed Length bar code on page 135 instructs the scanner that the next two programming labels scanned will define the second fixed label length. This setting must be between 04 and 16 characters. • The No Second Fixed Length bar code on page 135 configures the scanner to recognize only the label length chosen as the first fixed length.

Read Verification Read Verification is the number of times the scanner is required to read the bar code data before sending the label data to the host.

Configuring the MSI /Plessey Options Scan the following bar codes to configure the MSI/Plessey symbology options. Check Digit SET-------------------------------------

SR60 Scanner Programmer’s Reference Manual

131

Page 146

Chapter 4, Enabling and Configuring Symbologies

Calculate

---------

Don’t Calculate

---------

Transmit

---------

Don’t Transmit

---------

One Check Digit

---------

Two Check Digits ---------

END-----------------------------------

Label Length Format The next two sections explain how to set the MSI/Plessey label length format to either the Variable Length or Fixed Length format.

Variable Length Format You can set the MSI/Plessey to read Variable Length Format.

132

SR60 Scanner Programmer’s Reference Manual

Page 147

Chapter 4, Enabling and Configuring Symbologies

To set the MSI/Plessey to read Variable Length Format 1 Identify the minimum length setting you want to make. The selectable range is 04 to 16 characters. 2 Scan the SET bar code. 3 Scan the Enable Variable Length Format bar code. 4 Scan the Set Minimum Label Length bar code. 5 Using the Digits bar codes on page 135, scan the digits to set the minimum label length you identified in Step 1. Note: To set a label length less than ten, you must scan a zero digit first and then the length digit (such as 04, 06, or 08). 6 Scan the END bar code. Variable Length SET-------------------------------------

Enable Variable Length Format

---------

Set Minimum Label Length

---------

END------------------------------------

Fixed Length Format The scanner offers the option of requiring MSI/Plessey labels to have one or two fixed length(s) in the Fixed Label Format.

SR60 Scanner Programmer’s Reference Manual

133

Page 148

Chapter 4, Enabling and Configuring Symbologies

To set the MSI/Plessey symbology to fixed length format 1 Identify the fixed length setting(s) you wish to make. Fixed lengths can be set from 04 to 16 characters. 2 Scan the SET bar code. 3 Scan the Enable Fixed Length Format bar code. 4 Scan the Set First Fixed Length bar code. 5 Using the Digits bar codes on page 135, scan the digits to set the first fixed label length you identified in Step 1. Note: To set a label length less than ten, you must scan a zero digit first and then the length digit (such as 04, 06, or 08). • If you need to set a second fixed length, continue with Step 6. • If you do not need a second fixed length, scan the No Second Fixed Length bar code and skip to Step 8. 6 Scan the Set Second Fixed Length bar code. 7 Using the Digits bar codes on page 135, scan the digits to set the second fixed label length you identified in Step 1. Note: To set a label length less than ten, you must scan a zero digit first and then the length digit (such as 04, 06, or 08). 8 Scan the END bar code on page 135. Fixed Length SET-------------------------------------

Enable Fixed Length Format

134

---------

SR60 Scanner Programmer’s Reference Manual

Page 149

Chapter 4, Enabling and Configuring Symbologies

Set First Fixed Length

---------

Set Second Fixed Length ---------

No Second Fixed Length

---------

END------------------------------------

Digits

0

---------

1

---------

2

---------

SR60 Scanner Programmer’s Reference Manual

135

Page 150 read from a scan by OCR; it may hold reading errors

Chapter 4, Enabling and Configuring Symbologies

_ | | | || | | ;, _ | | | | Hl | ° _ | | Hil | en HT a Vl ce Un - me In

136 SR60 Scanner Programmer’s Reference Manual

Page 151

Chapter 4, Enabling and Configuring Symbologies

Read Verification Scan the following bar codes to set the number of reads to verify MSI/Plessey symbologies. Note: The more times the scanner is required to read and compare the bar code data, the longer the scanner takes to validate and transmit a label.

SET-------------------------------------

Set to One Read

---------

Set to Two Reads

---------

Set to Three Reads ---------

Set to Four Reads ---------

END------------------------------------

SR60 Scanner Programmer’s Reference Manual

137

Page 152

Chapter 4, Enabling and Configuring Symbologies

138

SR60 Scanner Programmer’s Reference Manual