For the Intermec SR60

Page 45

Chapter 2, Configuring Interface Settings

END------------------------------------

RS-232 Communication Parameters This section describes these RS-232 communication parameters: • Baud Rate • Data Format Settings: Data Bit, Parity Bit, and Stop Bit(s) • Handshaking • Hardware Handshaking (CTS/RTS) • Software Handshaking (XON/XOFF) • ACK/NAK Options • Intercharacter Delay For help changing other settings for this interface, see: • Chapter 3, “Configuring Label Transmit Settings,” on page 47. • “All Symbologies Supported by All Interfaces” on page 70. • Chapter 5, “Configuring General Features,” on page 139. Note: RS-232 Communication Parameters are not supported by the USB interface.

Baud Rate Scan the following bar codes to select the Baud Rate. Only one Baud Rate selection may be active at any one time. The last Baud Rate bar code you scan during a programming session is the setting that is stored when you scan the END bar code.

SET-------------------------------------

SR60 Scanner Programmer’s Reference Manual

31

Page 46

Chapter 2, Configuring Interface Settings

Baud Rate = 1200 ---------

Baud Rate = 2400 ---------

Baud Rate = 4800 ---------

Baud Rate = 9600 ---------

Baud Rate = 19200 ---------

Baud Rate = 38400 ---------

END------------------------------------

32

SR60 Scanner Programmer’s Reference Manual

Page 47

Chapter 2, Configuring Interface Settings

Data Format Settings Scan the following bar codes to select the data format configuration needed to communicate with your system.

SET-------------------------------------

Data Bit

Seven

---------

Eight

---------

Parity Bit

None

---------

Even

---------

SR60 Scanner Programmer’s Reference Manual

33

Page 48

Chapter 2, Configuring Interface Settings

Odd

---------

Mark

---------

Space

---------

Stop Bit(s)

One

---------

Two

---------

END------------------------------------

34

SR60 Scanner Programmer’s Reference Manual

Page 49

Chapter 2, Configuring Interface Settings

Handshaking Review your system documentation to identify handshaking requirements, and scan the following bar codes to change the settings if required. The following descriptions briefly explain each selection.

Hardware Handshaking You can choose either CTS/RTS Flow Control or CTS Scan Control: • CTS/RTS Flow Control is a type of hardware handshaking. The scanner activates the RTS (Request to Send) line when it is ready to send data to the host. The scanner waits for an active Clear to Send (CTS) signal from the host before transmitting data. If hardware control is disabled, CTS/RTS communication does not take place. If the host deactivates the CTS line during data transmission, the host receives additional characters for no more than 2 ms. (The timing varies slightly, depending on the baud rate you select.) Data

Disabled

Label Transmission

Xmission

Label Transmission

Active CTS

Inactive

CTS/RTS Flow Control Illustration

• CTS Scan Control is a type of hardware handshaking. When scan control is enabled, label scanning is disabled until CTS is asserted and de-asserted, as shown in the next illustration. Will not scan again until toggled Data

Label 1

Label 1

Label 2

Disabled until Assert CTS

De-assert

CTS Scan Control Illustration

Handshaking controls are mutually exclusive. You cannot enable more than one of these features at a time, because enabling multiple controls produces unpredictable results.

SR60 Scanner Programmer’s Reference Manual

35

Page 50

Chapter 2, Configuring Interface Settings

Note: Each handshaking feature requires a series of bar codes in the sequence given. That is, you must enter Programming mode by scanning the SET bar code, scan the Step #1 bar code, scan the Step #2 bar code, and then scan the END bar code.

Enable CTS/RTS Flow Control

SET-------------------------------------

Step #1

---------

Step #2

---------

END------------------------------------

Enable CTS Scan Control

SET------------------------------

36

SR60 Scanner Programmer’s Reference Manual

Page 51

Chapter 2, Configuring Interface Settings

Step #1

---------

Step #2

---------

END------------------------------------

Software Handshaking XON/XOFF is software handshaking that allows the host to control data transmission. If the host sends an XOFF command to the scanner, the scanner does not send the bar code data until it receives an XON command from the host. If the host sends the XOFF command during data transmission, the host receives additional characters for no more than 2 ms. (The timing varies slightly, depending on the baud rate you select.)

Enable XON/XOFF Control

SET-------------------------------------

Step #1

---------

SR60 Scanner Programmer’s Reference Manual

37

Page 52

Chapter 2, Configuring Interface Settings

Step #2

---------

END------------------------------------

Disable both CTS/RTS and XON/XOFF Control

SET-------------------------------------

Step #1

---------

Step #2

---------

END-----------------------------------

38

SR60 Scanner Programmer’s Reference Manual

Page 53

Chapter 2, Configuring Interface Settings

To disable either CTS/RTS Control or XON/XOFF Control 1 Disable both CTS/RTS Flow Control and XON/XOFF Control. 2 Enable one handshaking feature: • To enable CTS/RTS Flow Control, see page 36. • To enable XON/XOFF Control, see page 37.

RS-232 ACK/NAK Options Scan the following bar codes to configure the RS-232 ACK/NAK parameters for your scanner.

RS-232 ACK/NAK Options

SET-------------------------------------

Disable ACK/NAK ---------

Enable for Bar Code Transmission ---------

Enable for Host Command Acknowledge

---------

SR60 Scanner Programmer’s Reference Manual