Page 1 of ScanPlus 1800 Hand-held Scanner Installation Manual

Manual · Intermec

ScanPlus 1800 Hand-held Scanner Installation Manual

Manual170 pagesPDF 426 KB

Installation and setup manual for the Intermec ScanPlus 1800 hand-held scanner, with configuration bar codes for interfaces and symbologies.

What this file really is

The old site listed this file as “Installation Manual” for the Intermec 1800 PDF, 1800 SR and 4 more models. This is the installation manual for the ScanPlus 1800 hand-held scanner family (1800 SR, ST, PDF); it does not mention the 1802 by name.

Download the PDF426 KB

Names · 2 models

The models it names

Filed with · 4 models

Also filed with these models on the old site

Summary

What is in it

The installation manual for the Intermec ScanPlus 1800 hand-held bar code scanner. It explains setup with the EasySet software, resetting to factory defaults, connecting to a terminal or cash register by keyboard wedge, RS-232, laser emulation, wand emulation, IBM 46xx or OCIA, and data transmission settings for each interface. It then gives settings for symbologies from Codabar to UPC/EAN and PDF417, trigger and beep options, configuration modes, ASCII charts and test codes.

Its parts

  1. Using EasySet
  2. Reset all parameters
  3. Terminal / cash register used in your application
  4. Data transmission settings
  5. Symbologies
  6. Operating settings
  7. Configuration modes and utilities

From the manual

Key facts from this manual

Each line names its page in the PDF.

The Intermec ScanPlus 1800 Hand-held Scanner Installation Manual (P/N 0-360049-02, edition 1.5), a book of setup bar codes for the ScanPlus 1800 family, naming the 1800 ST laser model and the 1800 PDF for PDF417 codes. It does not name the 1802 by that number. It shows the cables for each interface and how to pick a terminal, set transmission, symbology and trigger options, and configure the scanner with EasySet or from a host.

Read for this summary: pages 1 to 7, 9 to 11, 13 to 23, 46, 102, 120, 127 and 137 to 139 of 170.

Device type
ScanPlus 1800 hand-held bar code scanner, laser and ccd models, with or without trigger p. 1, 120
Interfaces
Keyboard wedge, RS-232, laser emulation, wand emulation, IBM 46xx and OCIA cash registers p. 14, 15, 16, 17, 18
Wedge cables
Standard wedge 0-364037-00, DEC VT 220/320/420 0-364037-02, Wyse 0-365036-00, CMM-compatible 0-364037-03 p. 14
RS-232 cables
RS-232 direct cable 0-364032-00, dual RS-232 cable 0-364032-01 p. 15
Emulation cables
Laser emulation 0-366030-00; wand emulation 0-364031-00, or 0-366031-00 for energy saver p. 16, 17
Cash register cables
IBM 46xx 9x cable 0-365033-00; OCIA NCR 7052/7053 cable 0-365035-00 p. 18
Default RS-232
9600 baud, 7 data bits, even parity, 2 stop bits; 75 baud and up selectable p. 21, 46
Symbologies
Codabar, Code 39, Code 93, Code 128/EAN 128, Interleaved and Matrix 2 of 5, MSI, PDF417, Plessey, Standard 2 of 5, Telepen, UPC/EAN p. 5, 6
PDF417
Read only by the ScanPlus 1800 PDF, with buffered macro PDF for multi-label messages p. 102
Setup software
EasySet, offline by printed setup sheet or online over RS-232 cable 0-364032-00 p. 9
Stand
Raised stand 0360029-00 for hands-free autostand scanning p. 127
Laser class
The manual states the 1800 ST is a Class 2 laser product p. 2
Firmware
Flash memory upgradable online with RS-232 cable 0-364032-00 p. 139

What this manual walks you through

  • Setting up the scanner with EasySet, offline or online p. 9, 10
  • Resetting all parameters to factory defaults p. 11
  • Choosing the cable for each interface p. 14, 15, 16, 17, 18
  • Selecting a keyboard wedge terminal and keyboard language p. 19, 20
  • Configuring the scanner from a host in RS-232 slave mode, with checksum p. 22, 23
  • Setting trigger and autostand hands-free modes p. 120, 127
  • Reading the firmware version by beeps or screen p. 138
  • Locking out configuration after one minute p. 137

Good to know

  • The scanner stops working if trigger commands are used on non-trigger models, or energy saver mode and cable do not match; recover by a factory reset at power-up. p. 120
  • With cables numbered x-xx5xxx-xx, transmission settings must be read from the printed setup sheet with the normal product cable. p. 9
  • The flash upgrade command must be read as a printed code, not sent directly from EasySet. p. 139
  • A steady green LED means no terminal or cash register is selected. p. 13

Questions this manual answers

How do I reset an Intermec ScanPlus 1800 to factory defaults?

Scan the reset factory defaults code, then select the terminal or cash register you use, since the reset cancels that selection. p. 11

What are the default RS-232 settings of the ScanPlus 1800?

Standard RS-232 C at 9600 baud, 7 data bits, even parity, 2 stop bits. p. 21

What cable connects a ScanPlus 1800 to a PC serial port?

The RS-232 direct cable 0-364032-00, also used for online EasySet setup. p. 10

My ScanPlus 1800 stopped working after a trigger setting. How do I recover it?

Disconnect it, hold the trigger if it has one, and reconnect it over a reset factory defaults code. p. 120

What do the green LED flashes at power-up mean?

Their number shows the cable or interface setup: 7 flashes for keyboard wedge, 2 for RS-232. p. 13, 19

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. 1. Using EasySet9
    1. online setup with RS-232 cable 0-364032-0010
  2. 2. Reset all parameters11
  3. 3. Terminal / cash register used in your application13
    1. connections14
    2. predefined terminal selections19
    3. custom interface number28
  4. 4. Data transmission settings29
    1. keyboard wedge30
    2. RS-23246
    3. laser emulation63
    4. wand emulation66
    5. IBM 46xx cash registers71
    6. OCIA cash registers73
  5. 5. Symbologies77
    1. Codabar78
    2. Code 3982
    3. Code 9390
    4. Code 128 / EAN 12892
    5. Interleaved 2 of 595
    6. Matrix 2 of 598
    7. MSI Code100
    8. PDF417102
    9. Plessey Code107
    10. Standard 2 of 5109
    11. Telepen112
    12. UPC / EAN113
  6. 6. Operating settings119
    1. trigger activation120
    2. flashing mode126
    3. autostand mode127
    4. data decoding security129
    5. beeps / green indicator LED132
  7. 7. Configuration modes and utilities137
    1. temporary configuration mode140
  8. A. ASCII character codes141
  9. B. Additional preamble / postamble characters-Keyboard wedge157
  10. C. Number codes163
  11. D. Test codes165
  12. Index167

From the PDF’s own bookmarks.

The whole text · 22 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 81-8
  2. Pages 9 to 129-12
  3. 3. Terminal / cash register used in your application, pages 13 to 2013-20
  4. 3. Terminal / cash register used in your application, pages 21 to 2821-28
  5. 4. Data transmission settings, pages 29 to 3829-38
  6. 4. Data transmission settings, pages 39 to 4839-48
  7. 4. Data transmission settings, pages 49 to 5849-58
  8. 4. Data transmission settings, pages 59 to 6859-68
  9. 4. Data transmission settings, pages 69 to 7669-76
  10. 5. Symbologies, pages 77 to 8577-85
  11. 5. Symbologies, pages 86 to 9486-94
  12. 5. Symbologies, pages 95 to 10395-103
  13. 5. Symbologies, pages 104 to 112104-112
  14. 5. Symbologies, pages 113 to 118113-118
  15. 6. Operating settings, pages 119 to 127119-127
  16. 6. Operating settings, pages 128 to 136128-136
  17. 7. Configuration modes and utilities137-140
  18. A. ASCII character codes, pages 141 to 148141-148
  19. A. ASCII character codes, pages 149 to 156149-156
  20. B. Additional preamble / postamble characters-Keyboard wedge157-162
  21. Pages 163 to 166163-166
  22. Index167-170

The file

Revision and size

RevisionP/N 0-360049-02, Edition 1.5, 99/07/26
PublisherIntermec Technologies Corporation
Pages170
PDF426 KB
TextText from the PDF itself.

The first pages · 3 of 170

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 170
Page 2
Page 2of 170
Page 3