Page 39
4. Data transmission settings keyboard wedge not active (*)
\42\57\60
- special dual-character combinations not interpreted (original code string transmitted without interpretation) Example ( . I dual-character combination = <Tab> ) original Code 39 code:
interpreted and transmitted as:
msg . Ixx .I x-.I msg - . Ixx msg . Ixx .I x-.I msg - . Ixx always active
\42\58\60
- special dual-character combinations always interpreted as special keys Example ( . I dual-character combination = <Tab> ) original Code 39 code:
interpreted and transmitted as:
msg . Ixx .I x-.I msg - . Ixx msg<Tab>xx <Tab> x <Tab> msg<Tab>xx
ScanPlus 1800 - Installation Manual
39
Page 40
4. Data transmission settings keyboard wedge separate 2 character label
\42\5A\60
- special dual-character combinations interpreted if only 2 characters in the original code Example ( . I dual-character combination = <Tab> ) original Code 39 code:
interpreted and transmitted as:
msg . Ixx .I x-.I msg - . Ixx msg . Ixx <Tab> x-.I msg - . Ixx separate 2 character label or preceded by a hyphen
\42\59\60
- special dual-character combinations interpreted if only 2 characters in the original code or if there is a hyphen in front of the 2 characters Example ( . I dual-character combination = <Tab> )
40 original Code 39 code:
interpreted and transmitted as:
msg . Ixx .I x-.I msg - . Ixx msg . Ixx <Tab> x <Tab> msg<Tab>xx
ScanPlus 1800 - Installation Manual
Page 41
4. Data transmission settings keyboard wedge special keys transmission - only symbologies that support the full ASCII character set allow the encoding of special keyboard keys such as <Return> and <Tab> - no symbologies support the encoding of other function keys such as <PF1> and <PageDown> - the special keys transmission codes allow you to transmit special keyboard keys as a single keyboard character, a [<Ctrl> + character] combination, or an [<Alt> + decimal_sequence] combination control character conversion - emulates PC AT keyboard [<Ctrl> + character] sequence or transmits certain keyboard functions directly as single keyboard characters on (*)
\47\4D\60
- transmits the following characters directly as single keyboard characters: ASCII character:
transmitted as:
8 9 10 13 27
<Backspace> (not <Ctrl> H ) <Tab> (not <Ctrl> I ) (not transmitted) <Enter> (not <Ctrl> M ) <Escape> (not <Ctrl> [ )
- useful to avoid confusion for applications that already use control sequences as commands
ScanPlus 1800 - Installation Manual
41
Page 42
4. Data transmission settings keyboard wedge off
\47\4E\60
- transmits ASCII characters for decimal numbers 1 to 27 with the corresponding [<Ctrl> + character] sequence
Alt mode - emulates PC AT keyboard [<Alt> + decimal_sequence] function (for bar codes containing ASCII characters not on your keyboard) off (*)
\41\47\60 on
\41\46\60
- use only if necessary as transmission is slower !!! (all characters are transmitted as <Alt> sequences) Example "A { B" is transmitted as: <Alt> + <6> + <5> <Alt> + <1> + <2> + <3>
42
<Alt> + <6> + <6>
ScanPlus 1800 - Installation Manual
Page 43
4. Data transmission settings keyboard wedge inter-character delay - avoids dropping characters if transmitting decoded data too fast for the host system - do not use for IBM 46xx cash registers or laser/wand emulation !!! none (*)
\52\00\60
10 ms
\52\0A\60
20 ms
\52\14\60
30 ms
\52\1E\60
40 ms
\52\28\60
50 ms
\52\32\60 compose (ms): [range: 1-999 ms]
\52\60
- enter a number string and scan End Selection (Appendix C)
ScanPlus 1800 - Installation Manual
43
Page 44
4. Data transmission settings keyboard wedge inter-message delay - avoids dropping characters if transmitting decoded data too fast for the host system none (*)
\53\00\60
10 ms
\53\0A\60
30 ms
\53\1E\60
50 ms
\53\32\60
80 ms
\53\01\10\60
100 ms
\53\01\24\60 compose (ms): [range: 1-999 ms]
\53\60
- enter a number string and scan End Selection (Appendix C)
44
ScanPlus 1800 - Installation Manual
Page 45
4. Data transmission settings keyboard wedge end-of-transmission keyboard character status - sets keyboard to lower case or upper case at end of transmission - Code 39 is transmitted in upper case - Code 128 is transmitted in lower case / upper case (full ASCII) lower case (*)
\41\44\60 upper case
\41\45\60
ScanPlus 1800 - Installation Manual
45
Page 46
4. Data transmission settings RS-232
RS-232 - default values (*) are for standard RS-232 C (9600, 7, E, 2)
baud rate 75
\41\00\60
150
\41\01\60
300
\41\02\60
600
\41\03\60
1200
\41\04\60
2400
\41\05\60
4800
\41\06\60
46
ScanPlus 1800 - Installation Manual
Page 47
4. Data transmission settings RS-232 9600 (*)
\41\07\60
19200
\41\08\60
38400
\41\09\60 data bits 7 (*)
\42\60
8
\43\60 parity even (*)
\46\01\60 odd
\46\02\60 none
\46\00\60
ScanPlus 1800 - Installation Manual
47
Page 48
4. Data transmission settings RS-232 stop bits 1
\44\60
2 (*)
\45\60 hardware/software protocols timeout - the same timeout applies to all RS-232 protocols supported 1000 ms (*)
\51\0F\28\60 unlimited
\51\00\60 compose (ms): [range: 0-2500 ms]
\51\60
- enter a number string and scan End Selection (Appendix C)
48
ScanPlus 1800 - Installation Manual