Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 6 of 22

ScanPlus 1800 Hand-held Scanner Installation Manual: 4. Data transmission settings, pages 39 to 48

Pages 39 to 48 of 170, from ScanPlus 1800 Hand-held Scanner Installation Manual

The original document is the PDF (426 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 1800 PDF and Intermec 1800 ST

Page 39

4. Data transmission settings keyboard wedge not active (*)

\42\57\60

- special dual-character combinations not interpreted (original code string transmitted without interpretation) Example ( . I dual-character combination = <Tab> ) original Code 39 code:

interpreted and transmitted as:

msg . Ixx .I x-.I msg - . Ixx msg . Ixx .I x-.I msg - . Ixx always active

\42\58\60

- special dual-character combinations always interpreted as special keys Example ( . I dual-character combination = <Tab> ) original Code 39 code:

interpreted and transmitted as:

msg . Ixx .I x-.I msg - . Ixx msg<Tab>xx <Tab> x <Tab> msg<Tab>xx

ScanPlus 1800 - Installation Manual

39

Page 40

4. Data transmission settings keyboard wedge separate 2 character label

\42\5A\60

- special dual-character combinations interpreted if only 2 characters in the original code Example ( . I dual-character combination = <Tab> ) original Code 39 code:

interpreted and transmitted as:

msg . Ixx .I x-.I msg - . Ixx msg . Ixx <Tab> x-.I msg - . Ixx separate 2 character label or preceded by a hyphen

\42\59\60

- special dual-character combinations interpreted if only 2 characters in the original code or if there is a hyphen in front of the 2 characters Example ( . I dual-character combination = <Tab> )

40 original Code 39 code:

interpreted and transmitted as:

msg . Ixx .I x-.I msg - . Ixx msg . Ixx <Tab> x <Tab> msg<Tab>xx

ScanPlus 1800 - Installation Manual

Page 41

4. Data transmission settings keyboard wedge special keys transmission - only symbologies that support the full ASCII character set allow the encoding of special keyboard keys such as <Return> and <Tab> - no symbologies support the encoding of other function keys such as <PF1> and <PageDown> - the special keys transmission codes allow you to transmit special keyboard keys as a single keyboard character, a [<Ctrl> + character] combination, or an [<Alt> + decimal_sequence] combination control character conversion - emulates PC AT keyboard [<Ctrl> + character] sequence or transmits certain keyboard functions directly as single keyboard characters on (*)

\47\4D\60

- transmits the following characters directly as single keyboard characters: ASCII character:

transmitted as:

8 9 10 13 27

<Backspace> (not <Ctrl> H ) <Tab> (not <Ctrl> I ) (not transmitted) <Enter> (not <Ctrl> M ) <Escape> (not <Ctrl> [ )

- useful to avoid confusion for applications that already use control sequences as commands

ScanPlus 1800 - Installation Manual

41

Page 42

4. Data transmission settings keyboard wedge off

\47\4E\60

- transmits ASCII characters for decimal numbers 1 to 27 with the corresponding [<Ctrl> + character] sequence

Alt mode - emulates PC AT keyboard [<Alt> + decimal_sequence] function (for bar codes containing ASCII characters not on your keyboard) off (*)

\41\47\60 on

\41\46\60

- use only if necessary as transmission is slower !!! (all characters are transmitted as <Alt> sequences) Example "A { B" is transmitted as: <Alt> + <6> + <5> <Alt> + <1> + <2> + <3>

42

<Alt> + <6> + <6>

ScanPlus 1800 - Installation Manual

Page 43

4. Data transmission settings keyboard wedge inter-character delay - avoids dropping characters if transmitting decoded data too fast for the host system - do not use for IBM 46xx cash registers or laser/wand emulation !!! none (*)

\52\00\60

10 ms

\52\0A\60

20 ms

\52\14\60

30 ms

\52\1E\60

40 ms

\52\28\60

50 ms

\52\32\60 compose (ms): [range: 1-999 ms]

\52\60

- enter a number string and scan End Selection (Appendix C)

ScanPlus 1800 - Installation Manual

43

Page 44

4. Data transmission settings keyboard wedge inter-message delay - avoids dropping characters if transmitting decoded data too fast for the host system none (*)

\53\00\60

10 ms

\53\0A\60

30 ms

\53\1E\60

50 ms

\53\32\60

80 ms

\53\01\10\60

100 ms

\53\01\24\60 compose (ms): [range: 1-999 ms]

\53\60

- enter a number string and scan End Selection (Appendix C)

44

ScanPlus 1800 - Installation Manual

Page 45

4. Data transmission settings keyboard wedge end-of-transmission keyboard character status - sets keyboard to lower case or upper case at end of transmission - Code 39 is transmitted in upper case - Code 128 is transmitted in lower case / upper case (full ASCII) lower case (*)

\41\44\60 upper case

\41\45\60

ScanPlus 1800 - Installation Manual

45

Page 46

4. Data transmission settings RS-232

RS-232 - default values (*) are for standard RS-232 C (9600, 7, E, 2)

baud rate 75

\41\00\60

150

\41\01\60

300

\41\02\60

600

\41\03\60

1200

\41\04\60

2400

\41\05\60

4800

\41\06\60

46

ScanPlus 1800 - Installation Manual

Page 47

4. Data transmission settings RS-232 9600 (*)

\41\07\60

19200

\41\08\60

38400

\41\09\60 data bits 7 (*)

\42\60

8

\43\60 parity even (*)

\46\01\60 odd

\46\02\60 none

\46\00\60

ScanPlus 1800 - Installation Manual

47

Page 48

4. Data transmission settings RS-232 stop bits 1

\44\60

2 (*)

\45\60 hardware/software protocols timeout - the same timeout applies to all RS-232 protocols supported 1000 ms (*)

\51\0F\28\60 unlimited

\51\00\60 compose (ms): [range: 0-2500 ms]

\51\60

- enter a number string and scan End Selection (Appendix C)

48

ScanPlus 1800 - Installation Manual