Page 29
4. Data transmission settings
4. Data transmission settings - interface-specific communication parameters - modify data transmission settings to optimize performance
ScanPlus 1800 - Installation Manual
29
Page 30
4. Data transmission settings keyboard wedge keyboard wedge - default values (*) are for IBM PC AT and compatible - QWERTY English preamble [preamble]
[symbology id]
<data>
[postamble] none (*)
\45\53\3E\00\60 compose:
\45\53\60
- enter an ASCII / Special Wedge Characters string and scan End Selection (Appendix A and B) - maximum = 20 characters
30
ScanPlus 1800 - Installation Manual
Page 31
4. Data transmission settings keyboard wedge symbology identifier [preamble]
[symbology id]
<data>
[postamble]
AIM [preamble] [symbology id] <data> [postamble] - optional 3-character symbology identifiers standardized by the AIM Committee Example: " ] A 0 " identifies standard Code 39 without check digit - refer to the official AIM documentation on symbology identifiers for full information on the different processing options supported symbology
]
<symbology_id>
<processing_option>
Codabar Code 39 Code 93 Code 128/EAN 128 Interleaved 2 of 5 Matrix 2 of 5 Standard 2 of 5 MSI Code PDF417 Plessey Code Telepen UPC/EAN (1) UPC/EAN (2)
] ] ] ] ] ] ] ] ] ] ] ] ]
F A G C I X S M L P B E X
0, 2, 4 0, 1, 2, 4 0 0, 1 0, 1, 2 0 0, 1, 2 0, 1 0 0 0, 1 0, 3, 4 0
(1) UPC/EAN "standard" lengths = 8, 13, 15 (add-on 2), 18 (add-on 5) characters (2) UPC/EAN other lengths (no check digit, . . .) not transmitted (*)
\47\59\60
ScanPlus 1800 - Installation Manual
31
Page 32
4. Data transmission settings keyboard wedge transmitted
\47\58\60
- activates AIM symbology identifier transmission for all symbologies custom [preamble]
[symbology id]
<data>
[postamble] not transmitted (*)
\45\56\60 transmitted
\45\55\60
- activates custom symbology transmission for all symbologies identifier compose - compose 1 custom character Codabar: [range: 1]
\45\59\04\60
- enter an ASCII character and scan End Selection (Appendix A) - default = D
32
ScanPlus 1800 - Installation Manual
Page 33
4. Data transmission settings keyboard wedge Code 39: [range: 1]
\45\59\01\60
- enter an ASCII character and scan End Selection (Appendix A) - default = * Code 93: [range: 1]
\45\59\0D\60
- enter an ASCII character and scan End Selection (Appendix A) - default = D Code 128 / EAN 128: [range: 1]
\45\59\0B\60
- enter an ASCII character and scan End Selection (Appendix A) - default = D EAN-8: [range: 1]
\45\59\07\60
- enter an ASCII character and scan End Selection (Appendix A) - default = FF EAN-13: [range: 1]
\45\59\06\60
- enter an ASCII character and scan End Selection (Appendix A) - default = F
ScanPlus 1800 - Installation Manual
33
Page 34
4. Data transmission settings keyboard wedge Interleaved 2 of 5: [range: 1]
\45\59\02\60
- enter an ASCII character and scan End Selection (Appendix A) - default = I Matrix 2 of 5: [range: 1]
\45\59\0E\60
- enter an ASCII character and scan End Selection (Appendix A) - default = D MSI Code: [range: 1]
\45\59\0A\60
- enter an ASCII character and scan End Selection (Appendix A) - default = D PDF417: [range: 1]
\45\59\13\60
- enter an ASCII character and scan End Selection (Appendix A) - default = * Plessey Code: [range: 1]
\45\59\0C\60
- enter an ASCII character and scan End Selection (Appendix A) - default = D
34
ScanPlus 1800 - Installation Manual
Page 35
4. Data transmission settings keyboard wedge Standard 2 of 5: [range: 1]
\45\59\03\60
- enter an ASCII character and scan End Selection (Appendix A) - default = D Telepen: [range: 1]
\45\59\0F\60
- enter an ASCII string and scan End Selection (Appendix A) - default = * UPC-A: [range: 1]
\45\59\08\60
- enter an ASCII character and scan End Selection (Appendix A) - default = A UPC-E: [range: 1]
\45\59\09\60
- enter an ASCII character and scan End Selection (Appendix A) - default = E
ScanPlus 1800 - Installation Manual
35
Page 36
4. Data transmission settings keyboard wedge postamble [preamble]
[symbology id]
<data>
[postamble] none
\45\54\3E\00\60
Enter (*)
\45\54\04\02\01\60
Carriage Return
\45\54\04\02\02\60
Tab
\45\54\04\02\08\60
Field Advance
\45\54\04\02\04\60
Field Exit
\45\54\04\02\05\60
Down Arrow
\45\54\04\02\0F\60
36
ScanPlus 1800 - Installation Manual
Page 37
4. Data transmission settings keyboard wedge compose:
\45\54\60
- enter an ASCII / Special Wedge Characters string and scan End Selection (Appendix A and B) - maximum = 20 characters
ScanPlus 1800 - Installation Manual
37
Page 38
4. Data transmission settings keyboard wedge special keys interpretation (Code 39) - certain dual-character combinations in Code 39 bar codes can be interpreted and transmitted as special keyboard keys (Code 39 is not full ASCII and does not support direct encoding of special keyboard keys such as <Enter> and <Tab>) - only for keyboard wedge applications with Code 39 bar codes !!! (your product must be enabled to read Code 39 codes with the correct barcode length settings)
38 emulated key characters emulated key characters
DEL ENTER RETURN SEND FIELD + FIELD EXIT HOME END TAB ALT BACK TAB BACKSPACE right arrow left arrow up arrow down arrow CLEAR FIELD DUP ESC LINE FEED RESET CTRL SPECIAL
.A .B .C .D .E .F .G .H .I .J .K .L .M .N .O .P .Q .R .S .T .U .V .W .X
PF1 PF2 PF3 PF4 PF5 PF6 PF7 PF8 PF9 PF10 PF11 PF12 PF13 PF14 PF15 PF16 PF17 PF18 PF19 PF20 PF21 PF22 PF23 PF24
0A 0B 0C 0D 0E 0F 0G 0H 0I 0J 0K 0L 0M 0N 0O 0P 0Q 0R 0S 0T 0U 0V 0W 0X
ScanPlus 1800 - Installation Manual