Page 21

3. Terminal / cash register used in your application predefined terminal selections

RS-232 - switch off the host system before you connect the cables and power supply ! - 2 green LED flashes at power-up standard RS-232 C (9600, 7, E, 2)

\41\4A\01\24\60

- predefined terminal selection also available with the terminal selector - PC serial port compatible - customize individual RS-232 settings to suit your system after reading this parameter special RS-232 configurations TTL logical 0 = 0V (9600, 7, E, 2)

\41\4A\01\24\60

- customize individual RS-232 settings to suit your system after reading this parameter TTL logical 0 = 5V (9600, 7, E, 2)

\41\4A\01\24\40\50\60

- customize individual RS-232 settings to suit your system after reading this parameter PC Term (19200, 8, none, 2)

\41\4A\01\26\60

ScanPlus 1800 - Installation Manual

21

Page 22

3. Terminal / cash register used in your application predefined terminal selections slave mode (9600, 7, E, 2)

\41\4A\01\29\60

- for RS-232 C and RS-232 TTL with logical 0 = 0V - allows the ScanPlus 1800 to be configured or controlled directly by the host system via the RS-232 serial port - optimized high-security Code 128 transmission (start/stop, hexadecimal characters, checksum) 1. use "display data string mode" (see section 7 "Configuration modes and utilities") to display on a terminal screen the data string and checksum for the setup commands you want to send to the ScanPlus 1800 in slave mode (the EasySet "View - Data String" command displays the command data strings but does not display the checksum !) Example:

"Code 39 - active" = \ 41 \ 4C \ 60 \ 5E ("5E" = checksum)

Calculating the checksum 1. Calculate the weighted sum of the data string values (weight increases by 1 for each successive value) and include startB with weight 1 at the beginning : data string : startB 0x41 0x4C 0x60 weight : 1 1 2 3 weight * value : (1 * 0x68) + (1 * 0x41) + (2 * 0x4C) + (3 * 0x60)

=

0x261

2. Calculate the modulo 103 value (modulo 67 hex) of the sum: 0x261 modulo 0x67 = 0x5E (= checksum) (0x261 / 0x67 = 0x5 with remainder 0x5E) 3. Add the checksum to the data string Example: "Code 39 - active" = \41\4C\60\5E

2. remove the backslash separator characters from the data strings and adapt each string to slave mode format : <start>

<command>

<checksum>

<stop>

<68> xxxxxx xx

<6A>

Example: slave mode command = 68 41 4C 60 5E 6A

22

ScanPlus 1800 - Installation Manual

Page 23

3. Terminal / cash register used in your application predefined terminal selections 3. activate "slave mode" and reconfigure the standard RS-232 output parameters to suit your system if required - the ScanPlus 1800 goes into "temporary configuration mode" (see section 7 "Configuration modes and utilities") 4. send the commands from the host terminal to the ScanPlus 1800 (individually or as a list in a batch file) - the values displayed in "display data string mode" are hexadecimal values, make sure that the values you send from the host system correspond to these values - in our example, the ScanPlus 1800 must receive the hexadecimal value 41 or its equivalent (ASCII character "A" for example), not the decimal value "41" ! 5. send "update current configuration" (0x68 0x46 0x41 0x02 0x60 0x4C 0x6A) if you want to save the new configuration you have sent to the ScanPlus 1800 (see section 7 "Configuration modes and utilities")

simplified slave mode (9600, 7, E, 2)

\41\4A\01\2D\60

- for RS-232 C and RS-232 TTL with logical 0 = 0V - allows the ScanPlus 1800 to be configured or controlled directly by the host system via the RS-232 serial port - easy-to-monitor character string (same as the strings displayed with the EasySet "View Data String" command) but less secure than standard "slave mode" (no start/stop or checksum) 1. use the EasySet "View - Data String" command to obtain the data strings for the commands you want to send to the ScanPlus 1800 Example:

command for "Code 39 - active" = \ 4 1 \ 4 C \ 6 0

- if you use "display data string mode" (see section 7 "Configuration modes and utilities"), do not use the last 2 digits (checksum) 2. activate "simplified slave mode" and reconfigure the standard RS-232 output parameters to suit your system if required - the ScanPlus 1800 goes into "temporary configuration mode" (see section 7 "Configuration modes and utilities") 3. send the commands in ASCII format from the host terminal to the ScanPlus 1800 (individually or as a list in a batch file)

ScanPlus 1800 - Installation Manual

23

Page 24

3. Terminal / cash register used in your application predefined terminal selections 4. send "update current configuration" ( \ 4 6 \ 4 1 \ 0 2 \ 6 0 ) if you want to save the new configuration you have sent to the ScanPlus 1800 (see section 7 "Configuration modes and utilities")

laser emulation - switch off the host system before you connect the cable ! - no LED flash at power-up - activates "energy saver mode - active for read duration (2 s), standby after good read" (see section 6, "Operating settings - trigger activation") laser with trigger

\41\4A\02\04\60

- predefined terminal selection also available with the terminal selector wand emulation - predefined terminal selections also available with the terminal selector - switch off the host system before you connect the cable ! - 1 green LED flash at power-up - connecting a wand cable activates general wand interface default settings (see section 4, "Data transmission settings") if a specific wand interface is not already selected analog wand emulation (white high)

\41\4A\02\03\60

- bar = 0, space = 1, margin = 1, quiet zone = 1 - good read beeps after transmission, pulse duration = 1.32 ms, intermessage delay = 750 ms

24

ScanPlus 1800 - Installation Manual

Page 25

3. Terminal / cash register used in your application predefined terminal selections analog wand emulation (Intermec Interface, white high)

\41\4A\02\07\60

- bar = 0, space = 1, margin = 1, quiet zone = 1 - energy saver mode, active while trigger pressed, standby after good read (see section 6, "Operating settings - trigger activation") - beeps not active, good read LED before transmission, pulse duration = 0.15 ms, no intermessage delay - for Intermec products such as 97XX wedge products, JANUS 2010 hand-held computers, TRAKKER Antares 242X terminals, use : ScanPlus 1800 product

P/N

ScanPlus 1800 SR + wand emulation cable ScanPlus 1800 ST + wand emulation cable wand emulation cable

0-360051-01 0-366051-01 0-366031-00 digital wand emulation (black high)

\41\4A\02\02\60

- bar = 1, space = 0, margin = 0, quiet zone = 0 - good read beeps after transmission, pulse duration = 0.85 ms, intermessage delay = 750 ms

ScanPlus 1800 - Installation Manual

25

Page 26

3. Terminal / cash register used in your application predefined terminal selections

IBM 46xx cash registers - predefined terminal selections also available with the terminal selector - switch off the host system before you connect the cable ! - 3 green LED flashes at power-up - setup is independent of the physical link with the cash register (you can configure for Port 9x or Port 5x as required by the host) Port 9x

\41\4A\01\2E\60

- you cannot send this parameter online to the ScanPlus 1800 through RS-232 cable 0364032-00 !!! (send it to the setup sheet and read the configuration code with your normal IBM product cable connected) Port 5x

\41\4A\01\2F\60

- you cannot send this parameter online to the ScanPlus 1800 through RS-232 cable 0-36403200 !!! (send it to the setup sheet and read the configuration code with your normal IBM product cable connected)

26

ScanPlus 1800 - Installation Manual

Page 27

3. Terminal / cash register used in your application predefined terminal selections

OCIA cash registers - look in the terminal selector if you cannot find your system configuration in this section - switch off the host system before you connect the cable ! - 5 green LED flashes at power-up - if you have problems with your OCIA configuration, switch off the system to reset the cash register and your product and try another OCIA type TEC 1st type

\41\4A\01\38\60

- you cannot send this parameter online to the ScanPlus 1800 through RS-232 cable 0364032-00 !!! (send it to the setup sheet and read the configuration code with your normal OCIA product cable connected) TEC 2nd type

\41\4A\01\39\60

- you cannot send this parameter online to the ScanPlus 1800 through RS-232 cable 0-36403200 !!! (send it to the setup sheet and read the configuration code with your normal OCIA product cable connected) NCR

\41\4A\01\3A\60

- you cannot send this parameter online to the ScanPlus 1800 through RS-232 cable 0364032-00 !!! (send it to the setup sheet and read the configuration code with your normal OCIA product cable connected)

ScanPlus 1800 - Installation Manual

27

Page 28

3. Terminal / cash register used in your application custom interface number custom interface number compose: [range: 100-30000]

\41\4A\60

- enter a number string and scan End Selection (Appendix C) - for special host system configurations

28

ScanPlus 1800 - Installation Manual