Page 49
4. Data transmission settings RS-232
ENQ - ENQ not used: barcode data is transmitted without receiving a request from the host system - ENQ used: data is transmitted if ENQ character received from host system before end of hardware/software protocols time-out not used (*)
\47\3E\00\60 used (ENQ 05h)
\47\3E\05\60 compose:
\47\60
- enter an ASCII character and scan End Selection (Appendix A)
ACK - activating ACK or NAK activates the ACK/NAK protocol - before reading a new bar code after transmission, the product waits for an ACK (positive acknowledge) from the host system or until the end of the hardware/software protocols time-out not used (*)
\48\3E\00\60 used (ACK 06h)
\48\3E\06\60
ScanPlus 1800 - Installation Manual
49
Page 50
4. Data transmission settings RS-232 compose:
\48\60
- enter an ASCII character and scan End Selection (Appendix A)
NAK - activating ACK or NAK activates the ACK/NAK protocol - a NAK (negative acknowledge) indicates an unsuccessful transmission attempt - after 3 unsuccessful transmission attempts, message is aborted not used (*)
\49\3E\00\60 used (NAK 15h)
\49\3E\15\60 compose:
\49\60
- enter an ASCII character and scan End Selection (Appendix A)
50
ScanPlus 1800 - Installation Manual
Page 51
4. Data transmission settings RS-232
Typical ENQ / ACK / NAK scenarios host terminal
ScanPlus host terminal
ScanPlus
ENQ
ENQ message (OK)
message (not OK)
ACK (clears message)
NAK repeats message (OK)
ACK (clears message)
XON / XOFF software protocol - the host system controls the flow of data from the reader - XOFF (ASCII character DC3) from the host at the end of the hardware/software protocols timeout interrupts transmission - XON (ASCII character DC1) restarts the data flow not active (*)
\4B\60
ScanPlus 1800 - Installation Manual
51
Page 52
4. Data transmission settings RS-232 active
\4A\60
RTS / CTS hardware protocol - CTS is tested before transmission of each character - data is only transmitted when CTS is activated - RTS is activated before data is transmitted - RTS can be deactivated after transmission of each character, after transmission of the whole message, or after an RTS pulse which can be emitted when each character is transmitted not active (*)
\47\5F\00\60 active, RTS idle after each character
\47\5F\01\60 active, RTS idle after whole message
\47\5F\03\60 active, RTS pulse on each character
\47\5F\02\60
52
ScanPlus 1800 - Installation Manual
Page 53
4. Data transmission settings RS-232 compose delay before RTS idle (ms): [range: 0-2500 ms]
\47\5E\60
- enter a number string and scan End Selection (Appendix C) - default = 10 ms - delay for RTS idle after each character / idle after whole message - not valid for RTS pulse on each character preamble [preamble]
[symbology id]
<data>
[postamble] none (*)
\45\53\3E\00\60 compose:
\45\53\60
- enter an ASCII string and scan End Selection (Appendix A) - maximum = 20 characters preamble / postamble [preamble]
[symbology id]
<data>
[postamble] STX / ETX
\45\53\3E\02\45\54\3E\03\60
ScanPlus 1800 - Installation Manual
53
Page 54
4. Data transmission settings RS-232 symbology identifier [preamble]
[symbology id]
<data>
[postamble]
AIM [preamble] [symbology id] <data> [postamble] - optional 3-character symbology identifiers standardized by the AIM Committee Example: " ] A 0 " identifies standard Code 39 without check digit - refer to the official AIM documentation on symbology identifiers for full information on the different processing options supported symbology
]
<symbology_id>
<processing_option>
Codabar Code 39 Code 93 Code 128/EAN 128 Interleaved 2 of 5 Matrix 2 of 5 Standard 2 of 5 MSI Code PDF417 Plessey Code Telepen UPC/EAN (1) UPC/EAN (2)
] ] ] ] ] ] ] ] ] ] ] ] ]
F A G C I X S M L P B E X
0, 2, 4 0, 1, 2, 4 0 0, 1 0, 1, 2 0 0, 1, 2 0, 1 0 0 0, 1 0, 3, 4 0
(1) UPC/EAN "standard" lengths = 8, 13, 15 (add-on 2), 18 (add-on 5) characters (2) UPC/EAN other lengths (no check digit, . . .) not transmitted (*)
\47\59\60
54
ScanPlus 1800 - Installation Manual
Page 55
4. Data transmission settings RS-232 transmitted
\47\58\60
- activates AIM symbology identifier transmission for all symbologies custom [preamble]
[symbology id]
<data>
[postamble] not transmitted (*)
\45\56\60 transmitted
\45\55\60
- activates custom symbology transmission for all symbologies identifier compose - compose 1 custom character Codabar: [range: 1]
\45\59\04\60
- enter an ASCII character and scan End Selection (Appendix A) - default = D
ScanPlus 1800 - Installation Manual
55
Page 56
4. Data transmission settings RS-232 Code 39: [range: 1]
\45\59\01\60
- enter an ASCII character and scan End Selection (Appendix A) - default = * Code 93: [range: 1]
\45\59\0D\60
- enter an ASCII character and scan End Selection (Appendix A) - default = D Code 128 / EAN 128: [range: 1]
\45\59\0B\60
- enter an ASCII character and scan End Selection (Appendix A) - default = D EAN-8: [range: 1]
\45\59\07\60
- enter an ASCII character and scan End Selection (Appendix A) - default = FF EAN-13: [range: 1]
\45\59\06\60
- enter an ASCII character and scan End Selection (Appendix A) - default = F
56
ScanPlus 1800 - Installation Manual
Page 57
4. Data transmission settings RS-232 Interleaved 2 of 5: [range: 1]
\45\59\02\60
- enter an ASCII character and scan End Selection (Appendix A) - default = I Matrix 2 of 5: [range: 1]
\45\59\0E\60
- enter an ASCII character and scan End Selection (Appendix A) - default = D MSI Code: [range: 1]
\45\59\0A\60
- enter an ASCII character and scan End Selection (Appendix A) - default = D PDF417: [range: 1]
\45\59\13\60
- enter an ASCII character and scan End Selection (Appendix A) - default = * Plessey Code: [range: 1]
\45\59\0C\60
- enter an ASCII character and scan End Selection (Appendix A) - default = D
ScanPlus 1800 - Installation Manual
57
Page 58
4. Data transmission settings RS-232 Standard 2 of 5: [range: 1]
\45\59\03\60
- enter an ASCII character and scan End Selection (Appendix A) - default = D Telepen: [range: 1]
\45\59\0F\60
- enter an ASCII string and scan End Selection (Appendix A) - default = * UPC-A: [range: 1]
\45\59\08\60
- enter an ASCII character and scan End Selection (Appendix A) - default = A UPC-E: [range: 1]
\45\59\09\60
- enter an ASCII character and scan End Selection (Appendix A) - default = E
58