Page 104

5. Symbologies PDF417 optional fields - transmit additional information if present in the label - one or more fields possible in the same label file name not transmitted (*)

\48\51\00\60 transmitted

\48\51\01\60 segment count not transmitted (*)

\48\52\00\60 transmitted

\48\52\01\60 time stamp not transmitted (*)

\48\53\00\60 transmitted

\48\53\01\60

104

ScanPlus 1800 - Installation Manual

Page 105

5. Symbologies PDF417 sender not transmitted (*)

\48\54\00\60 transmitted

\48\54\01\60 addressee not transmitted (*)

\48\57\00\60 transmitted

\48\57\01\60 file size not transmitted (*)

\48\58\00\60 transmitted

\48\58\01\60 checksum not transmitted (*)

\48\59\00\60

ScanPlus 1800 - Installation Manual

105

Page 106

5. Symbologies PDF417 transmitted

\48\59\01\60

106

ScanPlus 1800 - Installation Manual

Page 107

5. Symbologies Plessey Code

Plessey Code - numerical symbology not active (*)

\41\5D\60 active

\41\5C\60 check digit not transmitted (*)

\44\57\60 transmitted

\44\56\60

ScanPlus 1800 - Installation Manual

107

Page 108

5. Symbologies Plessey Code barcode length = <start> + <barcode data> + <2-character check digit> + <stop> - minimum length possible = 5 characters maximum length possible = 25 characters - use the "compose minimum length" option if you know the minimum length of the codes in your application !!! any length (*)

\44\59\00\60

- cancels the last minimum length selection and accepts any valid length (from 5 to 25 characters) compose minimum length: [range: 5-25]

\44\59\60

- enter a number string and scan End Selection (Appendix C) - to optimize decoding performance and increase security, select the same length as the minimum length in your application (do not select a shorter length !!) minimum length = 6

\44\59\06\60

108

ScanPlus 1800 - Installation Manual

Page 109

5. Symbologies Standard 2 of 5

Standard 2 of 5 - numerical symbology - default format = Identicon (6 start/stop bars) - also referred to as "Straight 2 of 5" and "Industrial 2 of 5" not active (*)

\41\51\60 active

\41\50\60 format Identicon (6 start/stop bars) (*)

\43\47\60

Computer Identics (4 start/stop bars)

\43\46\60 check digit mod 10 not used (*)

\43\4A\60 checked and transmitted

\43\48\60

ScanPlus 1800 - Installation Manual

109

Page 110

5. Symbologies Standard 2 of 5 checked but not transmitted

\43\49\60 barcode length = <barcode data> + [check digit] - minimum length possible = 3 characters - if the codes in your application have fixed lengths, use the "compose 1 or 2 or 3 fixed lengths" option !!! compose 1 or 2 or 3 fixed lengths:

\43\4B\60

- enter a number string and scan End Selection for each length and scan End Selection twice to finish (Appendix C) - compose 1 or 2 or 3 fixed lengths provides the best performance and security if the codes in your application have fixed lengths - minimum length possible = 3 characters any length

\43\4C\00\60

- cancels any fixed length / minimum length settings and accepts any valid length (3 or more characters)

110

ScanPlus 1800 - Installation Manual

Page 111

5. Symbologies Standard 2 of 5 compose minimum length: [range: 3-50]

\43\4C\60

- enter a number string and scan End Selection (Appendix C) - compose a minimum length if the codes in your application do not have 1 or 2 or 3 fixed lengths - to optimize decoding performance and increase security, select the same length as the minimum length in your application (do not select a shorter length !!) minimum length = 6 (*)

\43\4C\06\60

ScanPlus 1800 - Installation Manual

111

Page 112

5. Symbologies Telepen

Telepen - alphanumeric full ASCII symbology - letter case defined - default format = ASCII not active (*)

\42\43\60 active

\42\42\60 format ASCII (*)

\47\4C\60 numeric

\47\4B\60

112

ScanPlus 1800 - Installation Manual