The text of a manual · part 2 of 22
ScanPlus 1800 Hand-held Scanner Installation Manual, pages 9 to 12
Pages 9 to 12 of 170: 1. Using EasySet; 2. Reset all parameters
The original document is the PDF (426 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 1800 PDF and Intermec 1800 ST
Page 9
1. Using EasySet
1. Using EasySet - offline setup 1. select your Intermec product in EasySet ("Select reader" icon over the product image) 2. double-click the setup commands in EasySet to send them to the setup sheet 3. print out the setup sheet and read the configuration codes - online setup : - use RS-232 cable 0-364032-00 for online setup (follow the procedure described under "online setup with RS-232 cable 0-364032-00" in this section) - models with cable P/N x-xx5xxx-xx : you can use RS-232 cable 0-364032-00 for online setup with these products, but for data transmission settings (section 4) you must connect your normal product cable and read the codes from the setup sheet (offline setup) !!!
start EasySet online setup
\41\4A\0F\29\60
- only necessary for setup with RS-232 cable 0-364032-00 - double-click the command to send it to the setup sheet - follow the procedure for online setup with RS-232 cable 0-364032-00
ScanPlus 1800 - Installation Manual
9
Page 10
1. Using EasySet online setup with RS-232 cable 0-364032-00 online setup with RS-232 cable 0-364032-00
RS-232 direct cable 0-364032-00
- online setup with RS-232 cable 0-364032-00 : 1. connect the RS-232 cable to your product if it is not already connected 2. connect the RS-232 cable to the serial port of your PC 3. connect the power supply to the RS-232 cable and provide electrical power 4. select your Intermec product in EasySet ("Select reader" icon over the product image) 5. read the "start EasySet online setup" code (double-click to send it to the setup sheet and print it out, or read it from the Getting Started Guide or Installation Manual) 6. open the "Configure communication PC/Reader" dialog box in the "Reader" menu 7. select the COM serial port your product is connected to (no parity, 8 data bits, 19200 bauds) 8. select the "Send to reader" checkbox under the commands window 9. double-click on the setup commands to send them directly to your product (they are also sent to the setup sheet) 10. connect your normal product cable to your product (if applicable) when you have finished online setup
10
ScanPlus 1800 - Installation Manual
Page 11
2. Reset all parameters
2. Reset all parameters - global reset of all parameter settings - useful for a first-time setup or for a fresh start with a new application - default settings are indicated by (*) reset factory defaults
\46\42\60
- resets all configuration parameters to their default values and cancels the terminal / cash register selection - after a global reset, you must select the terminal / cash register used in your application (>> next section) and customize your setup parameters if required
ScanPlus 1800 - Installation Manual
11
Page 12
2. Reset all parameters
12
ScanPlus 1800 - Installation Manual