The text of a manual · part 11 of 22
ScanPlus 1800 Hand-held Scanner Installation Manual: 5. Symbologies, pages 86 to 94
Pages 86 to 94 of 170, from ScanPlus 1800 Hand-held Scanner Installation Manual
The original document is the PDF (426 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 1800 PDF and Intermec 1800 ST
Page 86
5. Symbologies Code 39 Code 39
ASCII
Hex
Dec
+F +G +H +I +J +K +L +M +N +O +P +Q +R +S +T +U +V +W +X +Y +Z %P %Q %R %S %T f g h i j k l m n o p q r s t u v w x y z { | } ~ DEL
66 67 68 69 6A 6B 6C 6D 6E 6F 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 7F
102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 start/stop not transmitted (*)
\42\4D\60
86
ScanPlus 1800 - Installation Manual
Page 87
5. Symbologies Code 39 transmitted
\42\4C\60 accepted characters " * " only (*)
\42\4E\02\60
" $ " only
\42\4E\01\60
" $ " and " * " accepted
\42\4E\03\60 check digit not used (*)
\42\4F\60 modulo 43 - provides extra validation of data checked and transmitted
\42\50\60 checked but not transmitted
\42\51\60
ScanPlus 1800 - Installation Manual
87
Page 88
5. Symbologies Code 39
French CIP - French pharmaceutical industry - only used for codes with 7 characters checked and transmitted
\42\52\60 checked but not transmitted
\42\53\60
Italian CPI - Italian pharmaceutical industry - transmitted as standard Code 39 if checksum not validated checked and transmitted
\42\54\60 checked but not transmitted
\42\55\60
88
ScanPlus 1800 - Installation Manual
Page 89
5. Symbologies Code 39 barcode length = <start> + <barcode data> + [check digit] - minimum length possible = 3 characters
+
<stop>
- use the "compose minimum length" option if you know the minimum length of the codes in your application !!! any length (*)
\42\5C\00\60
- cancels the last minimum length selection and accepts any valid length (3 or more characters) compose minimum length: [range: 3-50]
\42\5C\60
- enter a number string and scan End Selection (Appendix C) - to optimize decoding performance and increase security, select the same length as the minimum length in your application (do not select a shorter length !!) minimum length = 6
\42\5C\06\60
ScanPlus 1800 - Installation Manual
89
Page 90
5. Symbologies Code 93
Code 93 - alphanumeric full ASCII symbology - letter case defined not active (*)
\41\5F\60 active
\41\5E\60 barcode length = <barcode data> - minimum length possible = 1 character - use the "compose minimum length" option if you know the minimum length of the codes in your application !!! any length (*)
\45\42\00\60
- cancels the last minimum length selection and accepts any valid length (1 or more characters) compose minimum length: [range: 1-50]
\45\42\60
- enter a number string and scan End Selection (Appendix C) - to optimize decoding performance and increase security, select the same length as the minimum length in your application (do not select a shorter length !!)
90
ScanPlus 1800 - Installation Manual
Page 91
5. Symbologies Code 93 minimum length = 6
\45\42\06\60
ScanPlus 1800 - Installation Manual
91
Page 92
5. Symbologies Code 128 / EAN 128
Code 128 / EAN 128 - alphanumeric full ASCII symbology - letter case defined - "EAN 128" = Code 128 with the FNC1 character in the first position - EAN 128 is auto-discriminating with Code 128 (recognition of the FNC1 start character used) not active (*)
\41\5B\60 active
\41\5A\60
EAN 128 identifier - the ]C1 AIM identifier for EAN 128 is automatically added by default in front of EAN 128 bar codes include ]C1 identifier (*)
\47\5A\01\60 remove ]C1 identifier
\47\5A\00\60
92
ScanPlus 1800 - Installation Manual
Page 93
5. Symbologies Code 128 / EAN 128
CIP 128 French pharmaceutical codes - embedded CIP 39 data - fixed length 14 characters - Code 128 character set C not active (*)
\47\5D\00\60 active
\47\5D\01\60
FNC1 separator character (EAN 128 norms) - default = GS function character (ASCII 29) - used as separator when multiple identifiers and their fields are concatenated - Example: useful for keyboard wedge interfaces where the GS character can not be transmitted compose:
\46\52\60
- enter an ASCII character and scan End Selection (Appendix A)
ScanPlus 1800 - Installation Manual
93
Page 94
5. Symbologies Code 128 / EAN 128 barcode length = <barcode data> - minimum length possible = 1 character - use the "compose minimum length" option if you know the minimum length of the codes in your application !!! - Code 128 / EAN 128 does not use the same number of characters to code alphanumerical data and numerical data - if you can not read bar codes in your application, this may be due to an unsuitable minimum length - try entering a shorter length ! any length (*)
\44\55\00\60
- cancels the last minimum length selection and accepts any valid length (1 or more characters) compose minimum length: [range: 1-50]
\44\55\60
- enter a number string and scan End Selection (Appendix C) - to optimize decoding performance and increase security, select the same length as the minimum length in your application (do not select a shorter length !!) minimum length = 6
\44\55\06\60
94
ScanPlus 1800 - Installation Manual