Page 128
6. Operating settings autostand mode compose activation cycle duration (sec): [range: 1-63 sec]
\4C\40\01\47\50\46\4D\47\51\60
- enter a number string and scan End Selection (Appendix C)
128
ScanPlus 1800 - Installation Manual
Page 129
6. Operating settings data decoding security data decoding security - ensures correct transmission of data for difficult reading conditions and varying levels of barcode quality (poorly printed labels, variable lengths and no check digit, "fragile" symbologies) - increasing the security level reduces the reading speed !!!
predefined security levels - predefined security level settings can be modified individually - use medium and high security levels for poor-quality bar codes or critical applications - increasing the security level reduces the reading speed !!! normal (*)
\45\4E\00\60
- single read before transmission - 300 ms between identical consecutive codes - no timeout between different consecutive codes medium
\45\4E\01\60
- 2 consecutive same reads before transmission - 300 ms between identical consecutive codes - 10 ms between different consecutive codes high
\45\4E\02\60
- 4 consecutive same reads before transmission - 350 ms between identical consecutive codes - 30 ms between different consecutive codes
ScanPlus 1800 - Installation Manual
129
Page 130
6. Operating settings data decoding security consecutive same read data validation - data is only transmitted after repeated reads give the same result single read before transmission (*)
\45\4B\01\60 compose number of same reads: [range: 0-10]
\45\4B\60
- enter a number string and scan End Selection (Appendix C)
timeout between identical consecutive codes - prevents reading the same bar code more than once 300 ms (*)
\45\4C\04\2C\60 compose (ms):
\45\4C\60
- enter a number string and scan End Selection (Appendix C)
130
ScanPlus 1800 - Installation Manual
Page 131
6. Operating settings data decoding security timeout between different consecutive codes - prevents unwanted reading of other bar codes on the same label none (*)
\45\4D\0A\60 compose (ms):
\45\4D\60
- enter a number string and scan End Selection (Appendix C)
ScanPlus 1800 - Installation Manual
131
Page 132
6. Operating settings beeps / green indicator LED beeps / green indicator LED volume high (*)
\4B\47\01\60 low
\4B\47\00\60 medium
\4B\47\02\60 note (tone frequency) high (2093.04 Hz) (*)
\4B\46\07\1E\60 low (1318.52 Hz)
\4B\46\0B\36\60 medium (1760 Hz)
\4B\46\08\38\60 compose frequency (Hz): [range: 100-4000 Hz]
\4B\46\60
- enter a number string and scan End Selection (Appendix C)
132
ScanPlus 1800 - Installation Manual
Page 133
6. Operating settings beeps / green indicator LED power-up beeps / power-up LED - 2 beeps = successful power-up - 3 long beeps = EEPROM integrity error (contact your Intermec representative !) on (*)
\45\5B\60 off
\45\5A\60 good read beeps number - "normal" bar codes: 1 beep (default) = good read - configuration codes: 2 beeps = good read, 6 beeps = setup error, 3 long beeps = EEPROM integrity error (contact your Intermec representative !) 1 (*)
\45\4A\00\60
2
\45\4A\01\60 none
\45\49\00\60
ScanPlus 1800 - Installation Manual
133
Page 134
6. Operating settings beeps / green indicator LED duration 60 ms
\45\49\3C\60
80 ms (*)
\45\49\01\10\60
200 ms
\45\49\04\2C\60
300 ms
\45\49\03\08\60 compose (ms): [range: 0-999 ms]
\45\49\60
- enter a number string and scan End Selection (Appendix C)
timing - IBM and OCIA cash registers : do not send this parameter online to the ScanPlus 1800 through RS-232 cable 0-364032-00 !!! (send it to the setup sheet and read the configuration code with your normal IBM / OCIA product cable connected) before transmission (*)
\45\52\60
134
ScanPlus 1800 - Installation Manual
Page 135
6. Operating settings beeps / green indicator LED after transmission
\45\51\60 good read LED on (*)
\45\4F\01\10\60 off
\45\4F\00\60
PDF417 codes - only available with the ScanPlus 1800 PDF - if you remove the ScanPlus from the PDF417 code for more than 10 seconds before you finish reading (before you hear a success beep), the data you have read so far will be lost and you will have to start again crackle - irregular crackle = reading new PDF417 data - the more intensive the crackle, the better the reading performance - regular tick during rescan or pause = data has already been read - regular continuous crackle = error-correction processing at end of read (especially with high security-level codes, poor quality codes) - single clear success beep = good read on (*)
\48\4A\01\60
ScanPlus 1800 - Installation Manual
135
Page 136
6. Operating settings beeps / green indicator LED off
\48\4A\00\60
LED flicker - green LED flicker = reading new PDF417 data - the more intensive the flicker, the better the reading performance on (*)
\48\4B\01\60 off
\48\4B\00\60
136