Page 119
6. Operating settings
6. Operating settings - settings that affect the way your product operates (trigger settings, flashing mode, data decoding security settings, beep characteristics)
ScanPlus 1800 - Installation Manual
119
Page 120
6. Operating settings trigger activation trigger activation - LASER SAFETY: the ScanPlus 1800 ST is a Class 2 Laser product - CAUTION - LASER LIGHT WHEN OPEN. DO NOT STARE INTO BEAM. - for laser and ccd trigger models standard mode with aiming beam energy saver mode ccd laser ccd --- ccd laser
- "trigger not active" = default for ccd trigger models - "standard mode - active while trigger pressed, standby after good read" = default for laser models - activating trigger options deactivates autostand mode and flashing mode - IMPORTANT : your ScanPlus will stop working if you : - use trigger commands with non-trigger models - activate energy saver mode without the special energy saver cable - connect a non-energy saver cable to a ScanPlus with energy saver activated - if this happens : 1. disconnect the ScanPlus 2. keep the trigger pressed (if applicable) and connect the ScanPlus over a "reset factory defaults" configuration code (read from setup sheet, Getting Started Guide or Installation Manual)
trigger not active (*)
\45\5D\00\60
- (*) default setting for ccd trigger models - laser beam always on if "trigger not active" for laser models - LASER SAFETY: the ScanPlus 1800 ST is a Class 2 Laser product CAUTION - LASER LIGHT WHEN OPEN. DO NOT STARE INTO BEAM.
120
ScanPlus 1800 - Installation Manual
Page 121
6. Operating settings trigger activation trigger operating scenarios - select a trigger operating scenario to activate the trigger - the same three operating scenarios are available for all ScanPlus trigger modes (standard, standard with aiming beam, energy saver): - active for read duration (2 s), repeat read duration after good read - active for read duration (2 s), standby after good read - active while trigger pressed, standby after good read - the ScanPlus does not flash in standby when the trigger is activated active for read duration (2 s) - repeat read duration after good read - read a number of bar codes after a single press of the trigger
2s 2s press trigger
2s good read good read
ScanPlus 1800 - Installation Manual standby
121
Page 122
6. Operating settings trigger activation active for read duration (2 s) - standby after good read - avoids double reading - when bar codes are close together for example
2s press trigger good read standby active while trigger pressed - standby after good read - selective reading of single bar codes press trigger good read standby
122
ScanPlus 1800 - Installation Manual
Page 123
6. Operating settings trigger activation standard mode - for laser and ccd trigger models - reading light and read function switched off during standby, full energy is restored when the next reading situation occurs - best mode for standard applications where energy consumption not critical : - fast wake-up time - keyboard-host communication ensured after ScanPlus time-out (necessary for wedge applications for example) - no current peaks during reading - LASER SAFETY: the ScanPlus 1800 ST is a Class 2 Laser product - CAUTION - LASER LIGHT WHEN OPEN. DO NOT STARE INTO BEAM. active for read duration (2 s), repeat read duration after good read
\46\5D\45\5D\02\46\4C\60 active for read duration (2 s), standby after good read
\46\5D\45\5D\02\46\4D\60 active while trigger pressed, standby after good read (*)
\46\5D\46\5A\03\3F\46\4D\60
- (*) default setting for laser models
ScanPlus 1800 - Installation Manual
123
Page 124
6. Operating settings trigger activation standard mode with aiming beam - for ccd trigger models only - same as standard mode but with aiming beam during standby active for read duration (2 s), repeat read duration after good read
\46\5C\45\5D\02\46\4C\60 active for read duration (2 s), standby after good read
\46\5C\45\5D\02\46\4D\60 active while trigger pressed, standby after good read
\46\5C\46\5A\03\3F\46\4D\60 energy saver mode - for laser and ccd trigger models - requires special energy saver cable ! - current consumption drops to zero during standby, full energy is restored when the next reading situation occurs - for energy-critical applications using laptop computers for example (use standard mode when possible) - deactivates power-up beeps / power-up LED (they cannot be activated) - IMPORTANT : your ScanPlus will stop working if you : - use trigger commands with non-trigger models - activate energy saver mode without the special energy saver cable - connect a non-energy saver cable to a ScanPlus with energy saver activated - if this happens : 1. disconnect the ScanPlus 2. keep the trigger pressed (if applicable) and connect the ScanPlus over a "reset factory defaults" configuration code (read from setup sheet, Getting Started Guide or Installation
124
ScanPlus 1800 - Installation Manual
Page 125
6. Operating settings trigger activation Manual) - LASER SAFETY: the ScanPlus 1800 ST is a Class 2 Laser product - CAUTION - LASER LIGHT WHEN OPEN. DO NOT STARE INTO BEAM. active for read duration (2 s), repeat read duration after good read
\46\5B\45\5D\02\46\4C\60 active for read duration (2 s), standby after good read
\46\5B\45\5D\02\46\4D\60 active while trigger pressed, standby after good read
\46\5B\46\5A\03\3F\46\4D\60 trigger read duration - same value for all trigger modes - select a trigger mode before you compose a custom read duration (selecting a trigger mode resets default read duration value of 2 s) - LASER SAFETY: the ScanPlus 1800 ST is a Class 2 Laser product - CAUTION - LASER LIGHT WHEN OPEN. DO NOT STARE INTO BEAM. 2 seconds (*)
\45\5D\02\60 compose (sec): [range: 2-65 sec]
\45\5D\60
- enter a number string and scan End Selection (Appendix C)
ScanPlus 1800 - Installation Manual
125
Page 126
6. Operating settings flashing mode flashing mode - LASER SAFETY: the ScanPlus 1800 ST is a Class 2 Laser product - CAUTION - LASER LIGHT WHEN OPEN. DO NOT STARE INTO BEAM. - for laser and ccd models - activating flashing mode deactivates trigger options and autostand mode - LED economizer flash during standby (changes to continuous beam when a bar code is presented) flash after 10 minutes (*)
\47\42\47\4F\47\51\0A\60
- (*) default setting for ccd models ("no flash" is the default setting for laser models) no flash (*)
\47\43\47\51\00\60
- (*) default setting for laser models ("flash after 10 minutes" is the default setting for ccd models) compose time-out before flash (min): [range: 1-60 min]
\47\42\47\4F\47\51\60
- enter a number string and scan End Selection (Appendix C)
126
ScanPlus 1800 - Installation Manual
Page 127
6. Operating settings autostand mode autostand mode - LASER SAFETY: the ScanPlus 1800 ST is a Class 2 Laser product - CAUTION - LASER LIGHT WHEN OPEN. DO NOT STARE INTO BEAM. - for laser and ccd trigger models used for automatic "hands-free" scanning with raised stand 0360029-00 for example (they can still be picked up and used manually !) - automatic autostand operation : - laser trigger models : half-speed laser economizer beam during automatic standby - ccd trigger models : LED economizer flash during automatic standby - all models change to continuous beam when a bar code is presented and are active for the specified activation cycle duration (default = 10 sec) - each good read within the activation cycle duration starts a new activation cycle - if there is no good read before the end of the activation cycle duration, the ScanPlus 1800 returns to automatic standby - after 1 hour of inactivity (no reads), the ScanPlus 1800 goes into full automatic standby (no reading light or read function, green LED blinks slowly): press the trigger to return to normal automatic autostand operation - manual autostand operation : - pressing the trigger one time puts the ScanPlus 1800 into manual standby for the specified activation cycle duration (default = 10 sec) - during manual standby, the reading light and read function are switched off - pressing the trigger before the end of the activation cycle duration activates the read function (active while trigger pressed, standby after good read) - releasing the trigger starts a new manual standby cycle - if the trigger is not pressed again before the end of the activation cycle duration, the ScanPlus 1800 returns to automatic autostand operation - a rapid double-click on the trigger returns the ScanPlus 1800 immediately to automatic autostand operation (does not wait until the end of the activation cycle duration) active for activation cycle duration (10 s), repeat activation cycle after good read
\4C\40\01\47\50\46\4D\47\51\0A\60
- activating autostand mode deactivates other trigger options and flashing mode
ScanPlus 1800 - Installation Manual