Manual · Allen-Bradley
Hand-Held Decoded Bar Code Scanners (Cat. No. 2755-HDG-4) User Manual
Manual115 pagesPDF 631 KB
User manual for the Allen-Bradley 2755-HDG-4 hand-held decoded laser bar code scanners, including connection to 2755-DS enhanced decoders.
Filed with · 1 model
Also filed with these models on the old site
Summary
What is in it
Allen-Bradley's user manual for the 2755-HDG-4 hand-held decoded bar code scanners. It describes the scanner's features, LEDs, scanning ranges and accessories, how to connect it through Synapse or AdaptaScan pass-through cables to RS-232 and keyboard wedge hosts, Enhanced Decoders (2755-DS1/DD1), PLC and SLC systems, how to configure symbologies and cable options with bar codes, plus troubleshooting, specifications, pinouts and an ASCII chart.
Its parts
- Scanner Features
- Connecting and Operating Scanner
- Configuring the Scanner
- Communication Setup (Cable Configuration)
- Troubleshooting and Maintenance
From the manual
Key facts from this manual
Each line names its page in the PDF.
User manual for the Allen-Bradley 2755-HDG-4 hand-held decoded laser bar code scanner and its Synapse and AdaptaScan Pass Through interface cables. It shows how to connect the scanner to RS-232 hosts, keyboards, bar code decoders and PLC-5 or SLC processors, how to configure it with bar codes, and how to read its beeps and troubleshoot it. The 2755-DS Enhanced Decoder appears only as a host the scanner can connect to.
- What it is
- Hand-held decoded laser bar code scanner, 2755-HDG-4 p. 1, 10
- Symbologies
- UPC-A, UPC-E, EAN 8, EAN 13, Codabar, Code 39, Code 39 Full ASCII, Interleaved 2 of 5, Discrete 2 of 5, Code 128, Code 93, MSI Plessey, EAN 128 p. 12
- Power
- 4.8 to 14.0V DC; 150 mA at 5V DC typical p. 17, 90
- Power supply
- 2755-HFP-D1, 100 - 240 VAC, 50 - 60 Hz, plugs into the Synapse cable p. 17
- Scanner cables
- 2755-HDC-GS1-08 (8 ft / 2.44 m) or 2755-HDC-GS1-20 (20 ft / 6.1 m), scanner to Synapse cable p. 16
- RS-232 cables
- 2755-HFC-SR2-01 (male 25-pin DB, Txd on pin 3); 2755-HFC-SR3-01 (female 9-pin DB, Txd on pin 2) p. 25
- Keyboard wedge cables
- 2755-HFC-SP1-01 IBM AT/XT (5-pin DIN); 2755-HFC-SP2-01 PS/2 (6-pin Mini-DIN); 2755-HFC-SV1-01 DEC VT220/320/420; 2755-HFC-SV2-01 DEC VT520 p. 27
- Other cables
- Scanner emulation Synapse cable 2755-HFC-SA1-01 (undecoded output); AdaptaScan Pass Through cable 2755-HDC-GA2-08 p. 18, 24
- Stands and boot
- Adjustable stands 2755-HFN-K1 (5 to 18 in) and 2755-HFN-K2 (9 to 16 in); multi-mount stand 2755-HFN-K3; protective boot 2755-HFN-H1 p. 18, 19
- Read range
- 7.5 mil: 0.0 to 7.0 in; 20.0 mil: 0.0 to 25.0 in; 55.0 mil: 3.0 to 55.0 in p. 14
- Size and weight
- 5.0 x 2.8 x 6.3 in (127 x 71 x 160 mm); 8.5 oz (240 g) p. 90
- Environment
- Operating -30 to 50 °C (-22 to 122 °F); humidity 5% to 95% noncondensing; 6 ft (1.8 m) drop to concrete p. 91
- Laser timeout
- 0.5 to 3 seconds, default 3 seconds p. 37, 42
- Configuration
- By scanning bar codes from the Bar Code Programming Guide, publication 2755-6.5 p. 39
What this manual walks you through
- Attaching and removing the scanner cable p. 22, 23
- Connecting the scanner to an RS-232 host p. 25, 26
- Connecting through a keyboard wedge cable p. 27, 28
- Wiring the AdaptaScan Pass Through cable p. 29, 30
- Connecting to an Enhanced Decoder, 2760-RB module, PLC-5 or SLC p. 31, 32, 33, 34, 35
- Testing the scanner and reading its beeps p. 36, 37, 38
- Configuring the scanner and its default settings p. 41, 42
- Troubleshooting common problems p. 87, 88
- Cleaning the scan window p. 89
- Hands-free operation in a stand p. 92
Good to know
- Do not install a Synapse cable with power applied to the cable or the host; connect the power supply last. p. 25, 26
- Use the Series B Gun Adapter 2755-NC16; the Series A adapter does not work with these scanners. p. 31
- The scanner cannot tell Code 39 and Code 39 Full ASCII apart. p. 12
- The scanner has no serviceable parts; do not open the housing. p. 89
- Do not clean the window with abrasive materials or solvents such as alcohol or acetone. p. 89
Questions this manual answers
What power supply does the 2755-HDG-4 scanner use?
Power supply 2755-HFP-D1 (100 - 240 VAC, 50 - 60 Hz), which plugs into the Synapse cable. Some hosts can power the scanner without it. p. 17
How do I connect the 2755-HDG-4 to an Enhanced Decoder?
For the scanner port, use scanner emulation Synapse cable 2755-HFC-SA1-01 with Series B Gun Adapter 2755-NC16. For the Aux port, use the 25-pin RS-232 Synapse cable 2755-HFC-SR2-01 and a null modem. p. 31, 32
What do 4 long low beeps from the scanner mean?
During normal operation they mean a format or transmission error: the scanner is not properly configured and the data is ignored. p. 37
How far away can the 2755-HDG-4 read a bar code?
It depends on the bar width: 0.0 to 7.0 in for 7.5 mil, 0.0 to 25.0 in for 20.0 mil and 3.0 to 55.0 in for 55.0 mil codes. p. 14
Why does the scanner show no scan beam?
The power supply may not be connected, the beam may have timed out (release the trigger and scan again), or the cable or scanner may be defective. p. 87
Contents
Chapters and sections
Each line opens the PDF at its page.
- Front Cover1
- Important User Information2
- Preface - Using this Manual6
- 1 - Scanner Features9
- 2 - Connecting and Operating Scanner20
- Overview21
- Scanner to Synapse Cable or AdaptaScan Pass Through Cable22
- Scanner Cable to Synapse Cable Connection23
- Scanner Emulation Synapse Cable Connections24
- RS-232 Synapse Cable Connections25
- Keyboard Wedge Synapse Cable Connections27
- AdaptaScan Pass Through Cable Connection29
- Scanner to Enhanced Decoder Scanner Port Application31
- Scanner to Enhanced Decoder Aux Port Application32
- Scanner to Flexible Interface (RB) Module Application33
- Scanner to PLC Application34
- Scanner to SLC Application35
- Operating the Scanner36
- Automatic Shutoff37
- Audible Response37
- Configuring the Scanner and Cables39
- 3 - Configuring the Scanner40
40 more lines, from page 44 on
- UPC / EAN Options44
- 4 - Communication Setup (Cable Configuration)57
- Cable Defaults57
- Setting RS-232 Synapse Cable Options58
- Setting IBM PC Keyboard Wedge Synapse Cable Options65
- Setting DEC VT520 Keyboard Wedge Synapse Cable Options69
- Setting DEC VT220/VT320/VT420 Keyboard Wedge Synapse Cable Options72
- Setting Scanner Emulation Synapse Cable Options75
- AdaptaScan Pass Through Cable Options80
- 5 - Troubleshooting and Maintenance86
- A - Specifications90
- B - Hands-Free Stand Operation92
- C - Scanner Pinout Connections93
- D - ASCII Chart94
- E - European Union Directive Compliance CE99
- Glossary101
- Index108
- Test Symbols114
- Back Cover115
The whole text · 15 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
- Pages 1 to 51-5
- Preface - Using this Manual6-8
- 1 - Scanner Features9-19
- 2 - Connecting and Operating Scanner, pages 20 to 2920-29
- 2 - Connecting and Operating Scanner, pages 30 to 3930-39
- 3 - Configuring the Scanner, pages 40 to 4840-48
- 3 - Configuring the Scanner, pages 49 to 5649-56
- 4 - Communication Setup (Cable Configuration), pages 57 to 6657-66
- 4 - Communication Setup (Cable Configuration), pages 67 to 7667-76
- 4 - Communication Setup (Cable Configuration), pages 77 to 8577-85
- 5 - Troubleshooting and Maintenance86-89
- Pages 90 to 9290-92
- Pages 93 to 9893-98
- Pages 99 to 10799-107
- Pages 108 to 115108-115
The file