Page 40
Chapter
3
Configuring the Scanner This chapter describes the scanner configuration options.
Important Notes on Configuring a Scanner Be aware of the following when configuring the scanner:
• Both the scanner and Synapse cable configuration bar codes are located in the Bar Code Programming Guide for Hand-Held Scanners (Publication 2755-6.5).
• Configure the scanner for use with a Synapse cable or AdaptaScan Pass Through cable. Separate scanner configuration codes are used for each cable type. Make sure you use the correct configuration codes. The programming guide has separate tabbed sections for Scanner Configuration (for Synapse Cable) and Scanner Configuration (for AdaptaScan Pass Through Cable)
• Chapter 4 describes the communication setup (cable configuration) codes for the RS-232, keyboard wedge cable, scanner emulation, and AdaptaScan Pass Through cables.
Scanner Configuration Bar Codes All programming codes may be found in the Bar Code Programming Guide for Hand-Held Scanners (Publication 2755-6.5). The scanner is always enabled to read Code 128 configuration labels since all configuration codes use this symbology.
Publication 2755-6.2
Page 41
3–2
Configuring the Scanner
Configuring the Scanner 1. Connect the interface cable to the scanner. 2. Apply power to the interface cable (if required). 3. Scan the SCAN THIS SYMBOL FIRST bar code (found in Bar Code Programming Guide, see page references below). 4. Then scan the SET SCANNER FOR (SYNAPSE or ADAPTASCAN) CABLE OPERATION bar code. 5. Select the scanner cable type. Scan ENABLE SYNAPSE CABLE if you are using one of the Synapse cables (RS-232, keyboard wedge, or scanner emulation). Scan the ENABLE ADAPTASCAN PASS THROUGH CABLE bar code if you are using the AdaptaScan Pass Through cable (Catalog No. 2755-HDC-GA2-08). Note: The scanner stores the Synapse cable and AdaptaScan pass through cable configurations separately. To change between configurations, scan the ENABLE SYNAPSE CABLE or ENABLE ADAPTASCAN PASS THROUGH CABLE bar code. 6. Configure the scanner by scanning the bar codes for the options you want to change. The scanner is currently set with default settings as listed on this and the following page.
Scanner Default Settings Item
Default Setting
Programming Guide ➀ Page Reference For AdaptaScan For All Other Cable Cables
Cable Type
AdaptaScan Pass Through Cable
2-2
1-2
Symbologies
All Enabled
2-4
1-4
Transmit UPC-A Check Digit
Enabled
2-8
1-8
Transmit UPC-E Check Digit
Enabled
2-8
1-8
Convert UPC-E to UPC-A
Disabled
2-8
1-8
EAN Zero Extend
Disabled
2-9
1-9
Publication 2755-6.2
Page 42
Configuring the Scanner
Item
Default Setting
3–3
Programming Guide ➀ Page Reference For AdaptaScan For All Other Cable Cables
Decode UPC / EAN Supplemental
Disabled
2-9
1-9
UPC-A Preamble
System Character
2-10
1-10
UPC-E Preamble
System Character
2-10
1-10
0
2-11
1-11
CLSI Editing
Disabled
2-12
1-12
NOTIS Editing
Disabled
2-12
1-12
Codabar Decode Redundancy
Disabled
2-12
1-12
Transmit Code 39 Check Digit
Disabled
2-13
1-13
Buffer Code 39
Disabled
2-13
1-13
Code 39 Full ASCII
UPC/EAN Security Level
Disabled
2-13
1-13
MSI Plessey Check Digit
One
2-14
1-14
MSI Plessey 2 Check Digit Algorithm
Mod 10 - Mod 10
2-14
1-14
Convert Interleaved 2 of 5 (14 digit) to EAN 13
Disabled
2-15
1-15
Interleaved 2 of 5 Code Length
14
2-15
1-15
Discrete 2 of 5 Code Length
12
2-15
1-15
Prefix
None
2-17
1-17
Suffix
None
2-17
1-17
Data Transmission Format
➁
2-19
1-19
Transmit No-Read Message
Disabled
2-19
1-20
Transmit Code ID Character
Disabled
2-20
1-20
Transmit AIm ID Character
Disabled
2-20
1-21
Audible Response
Enabled
2-21
1-21
➂
2-21
1-21
Laser On Timeout
3 Seconds
2-22
1-22
Hands-FreeOperationTimeout
60 minutes
2-24
1-23
Power Mode
➀ Bar Code Programming Guide for Decoded Scanners (Publication No. 2755-6.5) ➁ for AdaptaScan Cable = Suffix Only, for Synapse Cable = Data As Is ➂ for AdaptaScan Cable = Low Power, for Synapse Cable = Continuous
Publication 2755-6.2
Page 43
3–4
Configuring the Scanner
Select Cable Type Important: Select the cable type before configuring the scanner. The scanner configuration codes (and some options) for each cable type (Synapse and AdaptaScan Pass Through) are different. Each configuration is stored separately. The selections are:
• Enable Synapse Cable • Enable AdaptaScan Pass Through Cable (default) After configuring the scanner, you can switch between configurations by scanning the cable selection bar code.
Select Symbologies Scan the bar code labels for the symbologies you want the scanner to decode. Only enable the symbologies you expect to read. The scanner automatically discriminates between all of the following symbologies. The only exception is that the scanner cannot discriminate between Code 39 and Code 39 Full ASCII. The scanner can read and decode the following symbologies. All symbologies are enabled by default. UPC-A
UPC-E
Code 39
Code 39 Full ASCII
EAN 8
EAN 13
Interleaved 2 of 5
Discrete 2 of 5
Codabar
Code 128
MSI / Plessey
Code 93
EAN 128 To enable a symbology, scan the ENABLE bar code for the symbology. To disable a symbology, scan the DISABLE bar code. Publication 2755-6.2
Page 44
Configuring the Scanner
3–5
UPC / EAN Options The following options are available for UPC-A and UPC-E codes:
Transmit UPC-A Check Digit When enabled, UPC-A symbol data is transmitted with the check digit. Enabled is the default.
Transmit UPC-E Check Digit When enabled, UPC-E symbol data is transmitted with the check digit. Enabled is the default.
Convert UPC-E to UPC-A When enabled, this option converts UPC-E (zero suppressed) decoded data to a UPC-A format before sending the data. After conversion, output data will be affected by UPC-A programming selections such as preamble and check digit settings. Disabled is the default.
Decode UPC / EAN Supplemental When enabled, supplemental digits are decoded. If the supplemental digits are not enabled and a symbol having supplemental digits is read, the supplemental digits are ignored. On the other hand, if supplemental digits are enabled, only symbols with supplemental digits are decoded. Disabled is the default.
Autodiscriminate UPC / EAN with Supplementals When enabled, supplemental digits are decoded. Both codes with and without supplemental digits are decoded. Disabled is the default.
Publication 2755-6.2
Page 45
3–6
Configuring the Scanner
UPC / EAN Options (Continued) EAN 8 Zero Extend When enabled, five leading zeros are added to decoded EAN 8 symbol data. The five zeros make the EAN 8 symbols compatible with the EAN 13 format. Disabled is the default.
UPC-A / UPC-E Preambles The UPC preamble consists of the system character and country code. The system character is the the first character on the left side of the symbol. The country code for UPC is always 0. Select whether these characters are sent with the bar code data. System character is the default.
• system character only • country code and system character • no preamble Note: There are separate preamble programming codes for both UPC-A and UPC-E symbols.
Publication 2755-6.2
Page 46
Configuring the Scanner
3–7
UPC / EAN Decode Security Levels There are four levels of decode security. There is an inverse relationship between security and the ability to decode codes of varying quality. Increasing the security level, “tightens” the scanner’s requirements for a valid read. Select one of the levels below. The default security level is 0. This level is sufficient for most applications. Higher security levels:
• may result in more no-reads on poor quality labels • reduce the chance of mis-reads on poor quality labels Security Level
Decode Operation
0
At the level 0, the scanner decodes many poor or low quality codes while providing adequate security for UPC/EAN codes within specifications.
1
As the quality level of UPC / EAN bar codes decrease, certain digits are more susceptible to misreads ( 1, 2, 7, 8) If you have problems only decoding symbols with these digits, select this security level.
2
If you are having problems decoding poor quality bar codes and the problem isn’t limited to the digits ( 1, 2, 7, 8), select this level.
3
If you selected security level 2 and are still having problems decoding symbols, select this security level. Note: Only select this level if you are scanning high quality bar codes. The scanner will reject codes that are not within the specifications for the symbology.
Publication 2755-6.2
Page 47
3–8
Configuring the Scanner
Codabar Options The following options are available for Codabar bar codes:
NOTIS Editing When enabled, the scanner removes the start and stop characters from the decoded symbol data.
CLSI Editing When enabled, the scanner removes the start and stop characters and inserts a space after the 1st, 5th, and 10th characters of a 14 character Codabar Symbol. Note: Symbol length does not include start and stop characters.
Decode Redundancy for Codabar When enabled, a Codabar symbol must be read in both directions before being decoded.
Publication 2755-6.2
Page 48
Configuring the Scanner
3–9
Code 39 Options The following options are available for Code 39 symbols. Code 39 Check Digit When enabled, the scanner verifies the Code 39 check digit (modulo 43 check character). Code 39 Buffering (Scan and Store) When enabled, the scanner stores all Code 39 symbol data that has a leading space as the first character (following start pattern). As Code 39 labels are scanned for buffering, the scanner provides a high/low beep to indicate that the data is stored in the buffer. Up to 250 bytes of information may be stored. If you scan a symbol and the buffer is full, the scanner will provide three long high tone beeps. No transmission will occur and the data in the buffer is not affected. Note: Before you can disable Code 39 buffering, you must clear the buffer (see below). Clear Transmission Buffer Clears the Code 39 transmission buffer. You will hear a high/low/high beep after the buffer has been cleared. No data is transmitted.
Publication 2755-6.2