Page 77

Communication Setup (Cable Configuration)

4-21

Emulation Timeout Determines how long:

• the interface cable waits for the laser on signal from the scanner after the trigger is pulled.

• the scanner waits for a decode LED (check if Decode LED is enabled). These are the options:

• • • • •

3 second timeout (default) 4 second timeout 5 second timeout 10 second timeout 30 second timeout

Polarity Sets the polarity of the wand emulation signal. The selections are:

• Margin Low / Bar High (default) • Margin High / Bar Low Unknown Characters Unknown characters are characters not recognized by the scanner. When SEND BAR CODES WITH UNKNOWN CHARACTERS is enabled, all decoded bar code data is transmitted except for the unknown characters. If this option is disabled, bar codes containing one or more unknown characters are not transmitted.

Publication 2755-6.2

Page 78

4-22

Communication Setup (Cable Configuration)

Setting Scanner Emulation Synapse Cable Options (Continued) Convert All to Code 39 When enabled, decoded data is converted and transmitted as Code 39 data. Note: ASCII from the scanner is transmitted as Code 39 data.

Code 39 to Code 39 Full ASCII When enabled, Code 39 data is transmitted as Code 39 Full ASCII. The full ASCII option allows the scanner to output any ASCII character or control code (including non-printable characters). Refer to Appendix E for a list of the Code 39 Full ASCII codes.

Publication 2755-6.2

Page 79

Communication Setup (Cable Configuration)

4-23

Advanced Features The advanced feature options allow you to store communication parameters for 2 separate applications. If you have already configured the scanner, all of the communication settings are stored as Parameter 1 settings (default setting). Using the advanced feature options, you can also create Parameter 2 settings. When using the scanner, scan the correct parameter setting bar code for each application. To select and/or set Parameter Set 1 configuration: 1. Configure the scanner communications as described in this chapter. Since Parameter Set 1 is the default you do not have to scan the Parameter Set 1 bar code. To set Parameter Set 2 configuration: 1. Scan the PARAMETER SET 2 bar code. 2. Configure the scanner communication parameters as described in this chapter. To select and/or set defaults for a parameter set, scan the appropriate default bar code. The selections are:

• SET CABLE DEFAULTS CURRENT PARAMETER SET • SET CABLE DEFAULTS BOTH PARAMETER SETS

Publication 2755-6.2

Page 80

4-24

Communication Setup (Cable Configuration)

AdaptaScan Pass Through Cable Options The following define the communication options available when the scanner is connected to the AdaptaScan pass through cable.

• Catalog No. 2755-HDC-GA2-08 Default Settings Scan the SET ADAPTASCAN PASS THROUGH CABLE DEFAULTS bar code to set the default settings. The table below lists the defaults.

Default Setting

Refer to Description on Page:

Programming Guide➀ Page Reference

Baud Rate

9600

4-25

2-26

Parity

Even➁

4-25

2-27

Stop Bits

2➁

4-26

2-28

Data Bits

7➁

4-26

2-28

Hardware Handshaking

None

4-27

2-29

Software Handshaking

None

4-28

2-30

Beep on BEL

Disabled

4-29

2-31

0

4-26

2-32

Item

Intercharacter Delay

➀ Bar Code Programming Guide for Decoded Scanners (Publication 2755-6.5). ➁ We recommend that you set Parity = None, Stop Bits = 1, and Data Bits = 8 for communication with the AdaptaScan Bar Code Reader.

Publication 2755-6.2

Page 81

Communication Setup (Cable Configuration)

4-25

Baud Rate Sets the rate (bits per second) at which the scanner transmits data. The scanner baud rate setting must match the host setting. The selections are:

• • • • • •

600 1200 2400 4800 9600 (default) 19200

Parity Set the parity of each ASCII coded character that is transmitted. Make sure the parity matches the requirements of the host. The selections are:

• • • • •

Odd Even (default) Mark (parity bit always set to 1) Space (parity bit always set to 0) None

Note: We recommend that you set the parity to None when communicating with an AdaptaScan Bar Code Reader.

Publication 2755-6.2

Page 82

4-26

Communication Setup (Cable Configuration)

AdaptaScan Pass Through Cable Options (Continued) Number of Stop Bits The stop bit marks the end of each character transmitted. Set the number of stop bits to match the host device. The selections are:

• 1 Stop Bit • 2 Stop Bits (default) Note: We recommend that you set the number of stop bits to 1 when communicating with an AdaptaScan Bar Code Reader.

Data Bits Determines the number of data bits for each ASCII character. The selections are:

• 7 data bits (default) • 8 data bits Note: We recommend that you set the number of data bits to 8 when communicating with an AdaptaScan Bar Code Reader.

Intercharacter Delay Some devices require a delay between characters to process data (characters are sent at a lower rate). The default is 00 milliseconds, you can enter a value between 00 and 99 milliseconds.

Publication 2755-6.2

Page 83

Communication Setup (Cable Configuration)

4-27

Hardware Handshaking When enabled, handshaking verifies the readiness of a receiving device before transmitting data. You can enable or disable the hardware handshaking lines. This is how the scanner handshaking functions: 1. The scanner checks the Clear to Send (CTS) line. If CTS is active, the scanner will wait for up to 2 seconds and check the line again. If the line is still active, the scanner will provide an audible beep and any scanned data will be lost. 2. If the CTS line is not active, the scanner will assert the Request to Send (RTS) line and wait for two seconds for the host to assert the CTS line. When the host asserts the CTS line, the scanner transmits the data. 3. After the transmission is completed, the scanner negates the RTS. 4. The host device should then negate CTS. The scanner checks the CTS line on the next transmission.

Publication 2755-6.2

Page 84

4-28

Communication Setup (Cable Configuration)

AdaptaScan Pass Through Cable Options (Continued) Software Handshaking Software handshaking controls the transmission of data. Use software handshaking instead of (but not with) hardware handshaking. There are four options:

• • • • •

None (default) ACK/NAK Only ENQ Only ACK/NAK with ENQ XON/XOFF

ACK/NAK Only checks the result of a transmission. The scanner waits for one of two responses from the host: ACK which means a successful transmission or NAK which means there was a problem. Whenever the scanner receives a NAK, it retransmits the data up to three times. If an ACK is still not received after three attempts, the transmission is aborted and the scanner provides four short beeps. ENQ ONLY requires that the scanner receive an an enquire character (ENQ) from the host before sending data. With ENQ enabled, the scanner must receive an ENQ from the host within a two second period after the last scan or a transmission error occurs. The scanner provides four short beeps to indicate an error (ENQ not received). ACK/NAK with ENQ combines both ACK/NAK and ENQ options. With XON/ XOFF enabled, the scanner assumes an XON for the first transmission. The scanner transmits data until an XOFF is received from the host device. If an XON is not received within 30 seconds after an XOFF, a transmission error occurs.

Publication 2755-6.2

Page 85

Communication Setup (Cable Configuration)

4-29

Beep on BEL When enabled, the scanner beeps when a <BEL> character is detected on the RS-232 link. <BEL> may be used to indicate an event such as an illegal entry. Note: The scanner will not respond to a <BEL> character between decode attempts if the scanner is configured for low power operation.

Publication 2755-6.2