Manual · Allen-Bradley
Single/Dual-Head Enhanced Bar Code Decoders (Catalog No. 2755-DS1A, -DS4A, -DD1A, -DD4A) Series B Product Data
Manual40 pagesPDF 230 KB
Product data for the Allen-Bradley 2755-DS and 2755-DD Series B single and dual-head enhanced bar code decoders.
Covers · 1 model
The models it covers
Summary
What is in it
Allen-Bradley product data for the Bulletin 2755 Single/Dual-Head Enhanced Bar Code Decoders, catalog numbers 2755-DS1A, -DS4A, -DD1A and -DD4A, Series B. It describes the NEMA Type 1 and Type 4 enclosures, scanner ports, power supply, LEDs, optional LCD display, AUX and HOST ports and discrete I/O modules, then the decoder functions, symbologies, operating modes, configuration screens and host commands, mounting dimensions, accessories, ordering information and specifications.
Its parts
- Overview
- Decoder Features
- Decoder Functions
- Symbologies
- Operating Modes
- Configuration Screens
- Host Commands
- Mounting Dimension
- Accessories for Decoder
- How to Order Decoder
- How to Order Options
- Specifications
From the manual
Key facts from this manual
Each line names its page in the PDF.
This is Allen-Bradley product data (Publication 2755-2.43, September 1993) for the Series B Single/Dual-Head Enhanced Bar Code Decoders 2755-DS1A, -DS4A, -DD1A and -DD4A. It describes the single-head and dual-head versions in NEMA Type 1 or Type 4 enclosures, their ports, decode and trigger modes and PLC hookups. It also lists scanners, cables, I/O modules, ordering codes and specifications.
- Device
- Enhanced bar code decoder: single-head 2755-DS1A or -DS4A (one scanner port) or dual-head 2755-DD1A or -DD4A (two ports) p. 1
- Enclosure
- NEMA Type 1 (2755-DS1A, -DD1A) or NEMA Type 4 (2755-DS4A, -DD4A) p. 38
- Power
- 100 to 240 VAC nominal (85 to 264 VAC); 2755-DS1A or -DS4A 55 VA, 2755-DD1A or -DD4A 80 VA p. 38
- HOST port
- RS-232, RS-422 or DH485; ASCII protocol, or Allen-Bradley PCCC on DH485 only; 300 to 38400 baud p. 5, 39
- AUX port
- RS-232, for an ASCII terminal used for configuration or manual data entry p. 5
- Symbologies
- Code 39, UPC-A, UPC-E, EAN-8, EAN-13 (with 2 or 5 digit supplements), Code 128, Codabar, Interleaved 2-of-5; PharmaCode on DS1P, DS4P, DD1P, DD4P decoders p. 7
- LCD display
- Optional 2 line x 20 character backlit LCD; 2755-NR1 for customer installation p. 4, 37
- Discrete I/O
- Optional I/O Module Board: eight output positions, position 8 also accepts an input module p. 6
- I/O modules
- Output 2755-OB5S, -OA5S, -OM5S; input 2755-IB5S, -IA5S, -IM5S p. 34, 35
- Memory backup
- Capacitor keeps configuration 6 hours at 50C or 50 hours at 30C; optional 1747-BA battery up to five years p. 6
- Size and weight
- 10.25 (H) x 12 (W) x 4.57 (D) in.; 10 lbs (4.5 kg) maximum with all options p. 31, 38
- Scanners
- 2755-LD4, -LD8 laser diode scanners; 2755-L7, -L9, -L4, -L5 scan heads; hand-held scanners through the 2755-NC16 adapter (NEMA Type 1 only) p. 32, 34
- PLC links
- 2760-RB Flexible Interface Module, 1771-DB BASIC or 1771-DA ASCII I/O module, SLC 1746-BAS BASIC module, 1784-KR for DH485 p. 28, 29
- Power cords
- Replacements 77121-801-01, -02, -03 (NEMA Type 1); 77121-801-04, -05 (NEMA Type 4) p. 37
What this manual walks you through
- Reading the front panel LED indicators p. 4
- Switching the AUX port between configuration and manual data entry p. 5
- Choosing coordinated or independent scanning on a dual-head decoder p. 7
- Choosing continuous, continuous/unique or triggered decode mode p. 8
- Connecting the decoder to an Allen-Bradley PLC, SLC or host computer p. 28, 29, 30
- Mounting the decoder p. 31
- Choosing scanner and extension cables p. 32, 33
- Building a decoder catalog number with options p. 36
- Ordering the LCD, I/O board and power cords separately p. 37
Good to know
- A single-head decoder cannot be upgraded to add a second scanner port. p. 3
- The decoder is not UL listed or CSA approved when used with the European Harmonized power cord. p. 36
- Leave 6 inches (152 mm) of clearance above and below the decoder for cables and I/O wiring. p. 31
- Without the battery, a long power loss erases the Extended Match Code Table configuration and the match code counters. p. 6
- Output modules work as switches, not as a power source. p. 34
Questions this manual answers
Can a single-head 2755-DS decoder be upgraded to two scanners?
No. The single-head decoder cannot be upgraded to include a second scanner port; the dual-head 2755-DD1A or -DD4A has two. p. 3
What battery keeps the 2755 decoder configuration during power loss?
The optional 1747-BA battery keeps the configuration without outside power for up to five years. p. 6
What power does the 2755-DS1A decoder need?
It runs on 100 to 240 VAC nominal (85 to 264 VAC) and draws 55 VA; the dual-head models draw 80 VA. p. 38
Which bar codes does the 2755 enhanced decoder read?
Code 39, UPC-A and UPC-E, EAN-8 and EAN-13 with optional supplements, Code 128, Codabar and Interleaved 2-of-5; PharmaCode needs a P version decoder. p. 7
How does the 2755 decoder connect to an SLC 500?
Over RS-232 through the SLC BASIC Module 1746-BAS, or to an SLC 5/03 over the DH485 multidrop interface. p. 29
Contents
Chapters and sections
Each line opens the PDF at its page.
The whole text · 7 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file