Page 1

A–B

ALLEN-BRADLEY

Single/Dual-Head Enhanced Bar Code Decoders (Catalog No. 2755-DS1A,-DS4A,-DD1A,-DD4A) Series B

Product Data

Overview. The Enhanced Bar Code Decoders are available in a variety of configurations providing application flexibility. For example, the single-head decoders (Catalog No. 2755-DS1A or -DS4A) have one scanner port while the dual-head decoders (Catalog No. 2755-DD1A or -DD4A) have two. Plus, each decoder is available in a NEMA Type 1 or Type 4 enclosure. Other options available for each decoder include:

• LCD Display • I/O Module Board supporting up to eight output modules You can order these options with the decoder or as separate components for customer installation. In addition, Allen-Bradley offers a full line of accessories to support the decoders including scanners, package detectors, and cables.

Page 2

Product Data Bulletin 2755 Single/Dual-Head Enhanced Bar Code Decoders

Decoder Features

This section describes features of the Single and Dual-Head Bar Code Decoders including:

• NEMA Type Enclosures • Scanner Port(s) • Integrated 100-240V AC (nominal) Power Supply • LED Indicators • LCD Display • AUX and HOST Communication Ports • Discrete Input/Output Modules NEMA Type Enclosures The Single and Dual-Head Decoders are available in a NEMA Type 1 or NEMA Type 4 enclosure. All connections on the NEMA Type 4 enclosure comply with NEMA 4 standards. Although the installation differs for each they have the same features and operate identically. Figure 1 NEMA Type 1 Version POWER

SCANNER A Port

SCANNER B Port (DD Versions Only)

AUX Port RS-232

ALLEN-BRADLEY

HOST Port RS-232/422 &485 w/DH485 Protocol

BAR CODE DECODER

Optional LCD Display

LED Indicators

POWER CPU ACTIVE COMMUNICATION

LASER ON A TRIGGER ACTIVE A VALID READ A

LASER ON B TRIGGER ACTIVE B VALID READ B

Holes for Conduit or Optional Output Module Connectors

2

DISCRETE I/O

1 2 3 4 5 6 7 8

IEC 320 Power Connector and ON/OFF Switch

Page 3

Product Data Bulletin 2755 Single/Dual-Head Enhanced Bar Code Decoders

Scanner Ports The Dual-Head Decoder has two scanner ports, labeled Scanner A and Scanner B. The Single-Head Decoder has only the Scanner A port.➀ Figures 1 and 2 show the location of the ports. The scanner ports support all of the Allen-Bradley medium and high speed bar code scanners (see Accessories section). The scanners do not require a separate power supply; they receive power directly from the decoder. The NEMA Type 1 version of each decoder also supports all of the Allen-Bradley stop and scan Visible Laser Diode (VLD) fixed mount and hand-held scanners when used with the 2755-NC16 gun adapter. The scanners on the Dual-Head Decoders can operate in two modes:

• Coordinated Mode (Coordinated 1 and Coordinated 2) Scanners A and B operate in a coordinated mode, each using the same trigger source (Scanner A).

• Independent Mode (Independent Package Detect or Host Triggered) Scanner A and Scanner B operate with independent triggers. Figure 2 NEMA Type 4 Version SCANNER B Port SCANNER A Port (DD Versions Only)

AUX Port RS-232

ALLEN-BRADLEY

HOST Port RS-232/422 &485 w/DH485 Protocol

BAR CODE DECODER

Optional LCD Display

LED Indicators

POWER CPU ACTIVE COMMUNICATION

LASER ON A TRIGGER ACTIVE A VALID READ A

LASER ON B TRIGGER ACTIVE B VALID READ B

Holes for Conduit or Optional Output Module Connectors

DISCRETE I/O

1 2 3 4 5 6 7 8

ON/OFF Toggle Switch

NEMA Type 4 Power Connector

➀ The Single-Head Decoder cannot be upgraded to include a second port.

3

Page 4

Product Data Bulletin 2755 Single/Dual-Head Enhanced Bar Code Decoders

Power Supply An internal power supply provides power to the scanners and the decoder. The source voltage may range from 100 to 240 volts AC nominal (50 to 60 Hz). The power supply automatically adjusts to the input voltage.

LED Indicators Front panel indicators provide a visual indication of the operating status of the decoders. Figures 1 and 2 show the location of the LED indicators. Table 1 defines the color and function of each LED. Table 1 LED Indicators LED Label➀ Power CPU Active

Color Green Green

Communication Laser On A Trigger Active A Valid Read A Laser On B Trigger Active B Valid Read B Discrete I/O (1-8)

Yellow Red Yellow Green Red Yellow Green Red

Function Lights when the decoder is receiving power. Lights when the CPU is active and running. The LED turns off if a fault condition is detected. Lights when data is transmitting to or from the AUX port or HOST port. Lights when Scanner A is activated to turn on its laser light source. Lights when the decoder is in triggered mode and scanning has been triggered. Lights when a valid read occurs from Scanner A. Lights when Scanner B is activated to turn on its laser light source.➁ Lights when the decoder is in triggered mode and scanning has been triggered.➁ Lights when a valid read occurs from Scanner B.➁ Lights when an input or output module in position 1,2, 3, 4, 5, 6, 7, or 8 is closed.

➀ LED labels are available in five different languages. ➁ These LED indicators are not included with the Single-Head Decoder.

LCD Display The decoders support an optional 2 line x 20 character per line alphanumeric LCD Display for on-line viewing of:

• Bar code data • Output counter values • Decoder performance values The format of the display data is under user control via the configuration screens or host commands. The LCD Display can be ordered with the decoder or as a separate component for customer installation. Figures 1 and 2 show the location of the LCD Display.

4

Page 5

Product Data Bulletin 2755 Single/Dual-Head Enhanced Bar Code Decoders

AUX Port The AUX port communicates with a standard ASCII terminal using the RS-232 interface. This terminal is referred to as the AUX terminal. The AUX port can switch between two modes of operation.

• Decoder Configuration The ASCII terminal is used to access built-in setup menus to configure and monitor decoder operations; format and configure host communications; and display bar code data, output counters and decoder status.

• Manual Data Entry The ASCII terminal is used to: – enter data at the keyboard when the unattended scanners cannot read a label. This feature is useful when labels are damaged or missing. – display messages from the host. – display bar code data, output counters and decoder status. The decoder features an AUX Terminal jumper on the main logic board to switch between configuration and manual data entry operations. Another way to switch between these two modes is to connect specific pins in the AUX port connector. The port and logic board jumpers are initially set for decoder configuration operations.

HOST Port The HOST port supports RS-232, RS-422, and DH485 (Allen-Bradley multidrop interface). The HOST port allows the exchange of commands and data between the decoder and a host computer or Allen-Bradley PLC controller.

Power Connector and On/Off Switch The NEMA Type 1 decoder uses an IEC 320 power entry connector. The NEMA Type 4 decoder uses an environmental 3-pin connector with a separate ON/OFF toggle switch (that is sealed to comply with NEMA Type 4 standards). The power cords available for each decoder are listed under the Accessories Section.

5

Page 6

Product Data Bulletin 2755 Single/Dual-Head Enhanced Bar Code Decoders

Discrete I/O Modules The decoders support an optional I/O Module Board (eight positions for outputs with one position alternately accepting an input). With the optional I/O modules, the decoder can be used to control external AC or DC devices. Conditions that activate the outputs are under user control via the configuration screens or host commands. All positions accept an output module. Position 8 also excepts an input module. You can configure the decoder to automatically load scanned bar code data into the match code table. The input module (in position 8) can be used to reset the autoload data without using host commands or the configuration terminal. Each decoder has two conduit holes or optional connectors for wiring the I/O modules. The I/O Module Board is available in several variations for factory or customer installation. You can order the decoder with the I/O Module Board only, for customer installation of specific modules, or with 2 DC outputs and 1 DC input for ”out of the box” applications. Each option is listed under the Accessories sections.

Memory Backup The decoders are designed to retain configuration during short term power interruptions. Controlled discharge of an on-board capacitor supports configuration retention for 6 hours at an ambient temperature of or 50 hours at The capacitor accumulates a charge when power is restored. An optional battery (catalog number 1747-BA) may be used to retain the configuration without outside power for up to five years. When the optional battery is used, power interruptions (whether intentional or resulting from power supply “glitches”) will have no affect on operating memory. If the battery is not used, long term power loss (see above) will result in the loss of the Extended Match Code Table configuration, the Primary and Extended Match Code Counters, and the text examples contained in the Host Replacement Rules. Note that the Replacement Rules themselves will not be lost, but the test examples you have entered at the bottom of each rule page will be lost. Storage memory configuration is transferred into operating memory on restart if power is lost for a period longer than the on-board capacitor (and, if installed, optional battery) can support.

6