Page 7

Product Data Bulletin 2755 Single/Dual-Head Enhanced Bar Code Decoders

Decoder Functions

The decoder acquires and decodes bar code data from one or two scanners. The decoder can then:

• send the decoded data to a host device (computer, PLC or SLC), ASCII terminal, or LCD display

• apply Host Replacement Rules to incoming data, and send the result to a host device

• compare the decoded data to data stored in the Primary or Extended match table and use the results to operate up to eight discrete outputs. The decoder also maintains counters for package count, no-reads, and discrete output operations.

Symbologies

The decoders support the following bar code symbologies:

• Code 39 • UPC-A and UPC-E including optional 2 or 5 digit supplements • EAN-8 and EAN-13 including optional 2 or 5 digit supplements • Code 128 • Codabar • Interleaved 2-of- 5 • PharmaCode (Available in DS1P, DS4P, DD1P, or DD4P decoders) • Other symbologies in future product releases.

Operating Modes

When configuring the decoder, you can select from several operating modes. This section gives an overview of the different modes of operation.

Scanning Modes The Dual-Head Decoder supports two scanning modes:

• Coordinated Mode Scanner A and Scanner B are coordinated, using the same trigger source and set of configuration parameters.

• Independent Mode Scanner A and Scanner B operate independently, each using a separate trigger source and set of configuration parameters.➀

➀ Some parameters, such as Capture Count, Symbols per Scan, and Symbols per Package are shared in independent mode.

7

Page 8

Product Data Bulletin 2755 Single/Dual-Head Enhanced Bar Code Decoders

Decode Modes The Single and Dual-Head Decoders have three decode modes:

• Continuous Mode In continuous mode, the decoder attempts to decode every scan. Continuous mode is useful during initial setup to determine the optimum location of the scanner relative to the bar code labels. In this mode, the on-line performance indicator shows the percentage of valid scans.

• Continuous/Unique Mode This mode is similar to continuous mode except the decoder compares each new valid read to the previous valid read. If they are identical, the new data is discarded so that only unique data is transmitted to the host.

• Triggered Mode In triggered mode, the decoder uses one of the following trigger sources to initiate decoding: Host Command. The trigger source is a command generated by a host computer or programmable controller. Package Detect. The trigger source is a package detector connected to the scanner. Internal Timer. The trigger source is an internal timer that cycles the trigger on and off at a set time interval. Once triggered, the decoder continuously decodes bar codes until one of the following conditions occurs: Number of symbols (bar codes) per package count is satisfied. Trigger off command (stop scan character) received from host. Package detect signal is no longer present. No-read timer expires. In the triggered mode, you can configure the decoder to send information to a host device and/or operate the discrete outputs: Immediately After Valid Package This response mode sends decoded data to the discrete I/O and host immediately after the decode operation. This response mode is useful in high speed applications where maximum throughput is required. or

8

Page 9

Product Data Bulletin 2755 Single/Dual-Head Enhanced Bar Code Decoders

At End of Trigger This response mode sends decoded data to the discrete I/O and host when: Host sends the stop scan character or Package detect signal expires or No-read timer expires. This response mode is useful when timing of the discrete outputs or timing of host communications is critical.

Configuration Screens

The decoder has built-in menus and screens for configuration and monitoring operations. You access these menus by connecting one of several standard ASCII terminals to the AUX port of the decoder. The process of configuring the decoder at the AUX port is called AUX terminal configuration.

Select Language Screen The configuration menus and screens support five different languages: English, Spanish, French, German, Italian. You select a language from the screen shown below. All subsequent screens will display in the selected language.

9

Page 10

Product Data Bulletin 2755 Single/Dual-Head Enhanced Bar Code Decoders

Select CRT (Terminal) Type Screen From this screen, you select the type of terminal connected to the decoder.

Select Operation Menu The Select Operation screen is the main menu. From this screen, you select the operation you want to perform. The operations are grouped according to Configuration, Display, or System functions.

10

Page 11

Product Data Bulletin 2755 Single/Dual-Head Enhanced Bar Code Decoders

Configure Symbology Option 1 on the Select Operation menu accesses the Symbology configuration screen. Use this function to select symbologies for decoding and to define the operating parameters to use during decoding. Symbology/Length Checking Enable and disable symbologies for decoding, and help assure data integrity and optimum performance Supplements Enable or disable supplements for UPC/EAN symbologies. PharmaCode (PharmaCode versions only) provides full control for all PharmaCode variables.

Verification Enable verification of guard bars with Interleaved 2-of-5 symbols.

The decoder will auto discriminate between multiple symbologies. For optimum performance, enable only those symbologies and code lengths you intend to use.

Scanner Control, Primary Match Table, and Discrete I/O Option 2 on the Select Operation configuration screens. Use this function to configure scanner control, match codes, and discrete I/O operations. Scanner Control Control the operation of Scanner A and B (for Dual-Head Decoders).

Primary Match Code Table Holds up to eight (1-8) match code entries. You can define the symbology and up to 32 characters for each match code string.

Discrete I/O Controls the state (normally opened or normally closed) of the output modules, defines the source of the data (Dual-Headed Decoders only) and allows you to configure one of 11 conditions that will activate each output for a set duration.

11

Page 12

Product Data Bulletin 2755 Single/Dual-Head Enhanced Bar Code Decoders

Discrete I/O Conditions The Primary Match Code Counters and Outputs are triggered by a number of different events or conditions. These include:

• Verifying that a symbol or group of symbols was read or failed to be read S Read or No-Read.

• Comparing scanned data to pre-configured data stored in the Match Code Table

S Match Entry – Scanned data matches a specific table entry. S Match Complete – Scanned data matches a user-defined number of entries.

S Read and No-Match – Scanned data does not match any table entry S No-Read or No-Match – Either no symbol data was decoded (perhaps due to a damaged or missing label) or the decoded data did not exist in the table.

• Configuring the Match Code Table by scanning bar code symbols S Autoload – Allows the scanned data from the first package read to be automatically entered into the match code table. Subsequent matches to the original data will activate outputs.

S Autoload Input – Allows an operator to load new data into the match code table by activating a discrete input module (through a push button, key switch, or PLC output for example), and scanning a bar code symbol.

• Monitoring host communication flow to throttle product flow and prevent data loss

S Buffer Full – Indicates that the decoder’s host communications buffer is filling faster than data is being taken by the host. Output can be used, for example, to slow a conveyor.

S Buffer Overflow – Indicates that the host communications buffer was unable to store all the incoming data. Can be used to shut down a line until communications are restored, preventing further data loss. The parameter None disables the output, or can be used as a “dead man” switch (with normally closed contact) to indicate power loss or other problem with the decoder.

12

Page 13

Product Data Bulletin 2755 Single/Dual-Head Enhanced Bar Code Decoders

Extended Match Table and Counters You can use the screen illustrated that follows to set up match code entries in the Extended Match Code Table. You can define up to 128 entries here that provide added flexibility in response to incoming data over the Primary Match Codes described in the previous chapter. Using Extended Match Codes you can compare all incoming data against table entries that you create to meet your own unique needs. The decoder can then count valid matches, and optionally fire one or more outputs. Extended Match Codes provide a way to gather extremely detailed information based on decoder activity, and to exercise an additional level of control over decoder output activities. The Extended Match Codes differ from the Primary Match Codes in a number of ways

• Extended Match Code counters appear on the same screen from which they are controlled (the primary counters appear on a separate Status and Primary Counters screen)

• Extended Match Codes can activate multiple outputs, the duration of which are defined in the Primary Match Code Table (Primary Match Codes can each fire only a single output). This screen displays the extended match code table in eight sets of sixteen entries. Set one includes entries 1 through 16, Set 2 includes 17 through 32, and so on. The entry numbers (1 through 128) appear on the left side of the screen. Screen Status Parameters provide updates status, resetting options, and access to all 128 extended match code entries. Each set of 16 entries can be individual enabled or disabled. Extended Match Code Table 128 entries arranged in 8 screens of 16 each. The operating mode, scanner source, bar code symbology, as well as the 32-character match table string are configured here.

Loading Counts Individual counts and outputs are displayed here. Each match can be simply counted, or may additionally fire up to 8 discrete outputs. Outputs may be fired together or in a round robin sequence with each match.

13