Page 36
Product Data Bulletin 2755 Single/Dual-Head Enhanced Bar Code Decoders
How to Order Decoder
The Single and Dual-Head Decoders are available in different configurations. To order a decoder, use the following Catalog Number breakdown. You can order the decoder with options or separately for customer installation.
2755 - D S 1 A - 1 - U - B 1 - R 1 Bulletin Number LCD Display
Device DeviceType Type D = Decoder
Blank = No Display ➀ R1 = LCD Display, with Backlighting
Scan Heads
Discrete I/O Options
S = Single D = Dual
Blank = No I/O Installed ➀ B1 = I/O Board (no modules) B2 = I/O Board, 3 modules ➁ B5 = I/O Board, 1 NEMA Type 4 Connector/Cables B6 = I/O Board, 2 NEMA Type 4 Connectors/Cables B7 = I/O Board, 3 modules, 2 NEMA Type 4 Connectors/Cables ➁
Enclosure Type 1 = UL, NEMA Type 1 4 = UL, NEMA Type 4
Manual Language Functions A = Standard Device P = Pharmacode Capability Included
Blank = English ➀ U = No Manual Included
Power Cords Power Cords for NEMA Type 1 Blank = 120 VAC, IEC 320, terminated plug prong, US style power cord 0 = No Cord (user must supply) 1 = 240 VAC, three wire (US Color Code) unterminated power cord 2 = 240 VAC, three wire (European Harmonized) unterminated power cord ➂ Power Cords for NEMA Type 4 Blank = 120/240 VAC, three wire (US Color Code) unterminated power cord 0 = No Cord (user must supply) 3 = 240 VAC, three wire (European Harmonized) unterminated power cord ➂ ➀ For applications that do not require special hardware, these fields are omitted. For example: A NEMA Type 1, Dual Scan Head Decoder with only an LCD display = 2755–DD1A–R1 ➁ 2 DC output modules and 1 DC input module. ➂ Decoder is not UL listed/CSA approved when used with the European Harmonized power cord.
36
Page 37
Product Data Bulletin 2755 Single/Dual-Head Enhanced Bar Code Decoders
How to Order Options
Decoder options can also be ordered separately for customer installation. Options include the LCD Display, variations of the I/O Module Board, and replacement power cords.
LCD Display The 2 line x 20 character LCD Display with backlighting is available for customer installation by ordering Catalog No. 2755-NR1.
I/O Module Board Options I/O Module Board options available for customer installation are listed below with catalog numbers. These options can be used with the NEMA Type 1 or Type 4 Decoders. Catalog No. 2755-NB0 2755-NB1 2755-NB2
Module I/O Board No Yes Yes
Qty 0 0 2
Output Modules Positions Type –– –– –– –– 1, 2 3 - 60 VDC at 0.5 amps
Qty 0 0 1
Input Module Position Type –– –– –– –– 8 3.3 - 32 VDC
I/O Connector/ Cables① 1 set None None
① The I/O connector(s) wire to modules in positions 1-8 of the I/O board and comply with NEMA Type 4 standards. Six foot (1.83 meter) cables are supplied with each connector for wiring to the modules.
Replacement Power Cords Replacement power cords available for the NEMA Type 1 decoder are listed below with replacement part numbers. Replacement Part No. 77121-801-01 77121-801-02 77121-801-03
Power Cord Description 120 VAC, 320 IEC, terminated three prong, U.S. style power cord 240 VAC, three wire (U.S. Color Code) unterminated power cord 240 VAC, three wire (European Harmonized) unterminated power cord①
① The decoder is not UL listed/CSA approved when used with this power cord.
Replacement power cords available for the NEMA Type 4 decoder are listed below with replacement part numbers. The decoder is not UL listed/CSA approved when used with this power cord.
Replacement Number 77121-801-04 77121-801-05
Power Cord Description 120/240 VAC, three wire (US Color Code) unterminated power cord 240 VAC, three wire (European Harmonized) unterminated power cord①
① The decoder is not UL listed/CSA approved when used with this power cord.
37
Page 38
Product Data Bulletin 2755 Single/Dual-Head Enhanced Bar Code Decoders
Specifications
Electrical Input Line Voltage
85 (Min) to 264 (Max) VAC 100 to 240 VAC Nominal 47 - 63 Hz
Input Line Frequency Power Catalog No. 2755-DS1A or -DS4A 55VA Catalog No. 2755-DD1A or -DD4A 80VA I/O Module Protection
Fuse (Replacement Part No. 77104-899-01)
Output Module Voltage/Current Catalog No. 2755-0B5S Catalog No. 2755-0A5S Catalog No. 2755-0M5S
3-60 VDC, 0.5A Max 12-140 VAC, 0.5A Max 24-280 VAC, 0.5A Max
Input Module Voltage Catalog No. 2755-IB5S Catalog No. 2755-IA5S Catalog No. 2755-IM5S
3.3-32 VDC 90-140V RMS/DC 180-280V RMS/DC
Mechanical Enclosure Catalog No. 2755-DS1A or -DD1A NEMA Type 1 Catalog No. 2755-DS4A or -DD4A NEMA Type 4
38
LED Indicators POWER ON CPU ACTIVE COMMUNICATIONS LASER ON A TRIGGER ACTIVE A VALID READ A LASER ON B TRIGGER ACTIVE B VALID READ B DISCRETE I/O 1 to 8
Green Green Yellow Red Yellow Green Red Yellow Green Red
Weight
10 lbs (4.5 kg) maximum, with all options installed
Dimensions Inches Centimeters
10.25 (H) x 12 (W) x 4.57 (D) 26.0 (H) x 30.5 (W) x 11.6 (D)
Environment Ambient Temperature Operating Storage Relative Humidity
0 to 50° C (32 to 122° F) -40 to 85° C (-40 to 185° F) 5 to 95%, noncondensing
Page 39
Product Data Bulletin 2755 Single/Dual-Head Enhanced Bar Code Decoders
Scanner Ports Scanner Ports A and B Connector (NEMA Type 1) Connector (NEMA Type 4) Communications HOST Port Electrical Standards Protocols
15-pin (female) subminiature D 19-pin (male) circular Cannon KPT series
Connector (NEMA Type 1) Connector (NEMA Type 4) Baud Rate Parity Data Bits Stop Bits Flow Control
RS-232, RS-422, RS-485 ASCII (RS-232, RS-422, DH485) Allen-Bradley PCCC (DH485 only) 25-pin (female) subminiature D 19-pin (male) circular Cannon KPT series① 300, 1200, 2400, 4800, 9600, 19200, 38400 None, Odd, Even 8 or 7 1 or 2 None, XON/XOFF, RTS/CTS
AUX Port Electrical Standard Connector (NEMA Type 1) Connector (NEMA Type 4) Data Bits Stop Bit Baud Rate Parity
RS-232 25-pin (female) subminiature D 19-pin (male) circular Cannon KPT series① 8 1 9600 None
LCD Display (Optional) Number of lines Number of characters/line Backlighting
2 20 characters/line Continuous LED backlighting
Decoded Symbologies
Code 39 (Standard Set) Interleaved 2-of-5 Code 128 UPC-A with optional 2 or 5 digit supplements UPC-E with optional 2 or 5 digit supplements EAN-8 with optional 2 or 5 digit supplements EAN-13 with optional 2 or 5 digit supplements Codabar PharmaCode
① Catalog Number 2755-NC17 Connector Kit is available for the NEMA Type 4 HOST and AUX port.
39
Page 40
PLC is a registered trademark of Allen-Bradley Company, Inc.
Publication 2755-2.43 – September, 1993 Supersedes Publication 2755-2.43 – March, 1992
Copyright 1993 Allen-Bradley Company, Inc. Printed in USA