Page 1 of Accu-Time Series 7000 Access Control Unit User's Manual

Manual · Accu-Time

Accu-Time Series 7000 Access Control Unit User's Manual

Manual105 pagesPDF 1.2 MB

User's manual for the Accu-Time Series 7000 Access Control Unit: installation, wiring, DIP switches and host commands.

Download the PDF1.2 MB

Covers · 1 model

The models it covers

Summary

What is in it

This manual describes the Accu-Time Series 7000 Access Control Unit (ACU), which controls access through a building's doors, usually one unit per door. It explains the operating modes, validation tables, schedules, door lock and alarm operation, anti-passback and host communications, then covers installation, cabling, reader and DI/DO wiring, DIP switches and jumpers. A full command reference follows, with appendices on pinouts, reader connections, terminal addresses and a sample download file.

Its parts

  1. Preface
  2. Introduction
  3. Installation
  4. Commands

From the manual

Key facts from this manual

Each line names its page in the PDF.

Accu-Time Systems' user's manual (MANU7000-01h, printed August 2004) for the Series 7000 Access Control Unit, a controller that runs a door with its badge readers, door lock and alarm. It gives the technical summary and explains site selection, power, cabling, reader and relay wiring, DIP switch and jumper settings. Later chapters hold the host command set.

Read for this summary: pages 1 to 3, 14 to 21, 27 to 41 and 91 to 93 of 105.

Device
Access control unit for building doors, typically one per door, wired to the door lock, readers and alarms p. 14
Readers
Two reader connections, both the same type: barcode (code 39 only), magnetic ABA Track II, clock-and-data proximity, or keypad p. 15, 27
Digital I/O
Two digital inputs; two form C relay outputs, NO or NC, switching 4-30 volts DC @ 7 amps p. 15
Communications
RS232 (one RJ45 socket, direct to a PC) and RS485 (two RJ45 sockets, multi-drop); default 9600 baud, 8 data bits, 1 stop bit, no parity p. 15, 27
Power
Unregulated 9-18 VDC, nominal 12 VDC @ 300 mA with no options; 2.5mm socket, positive inside p. 31, 91
Door strike power
12VDC output, 1A less the amount the Series 7000 draws p. 16
Processor and memory
Enhanced 8051 derivative; 512K PROM; 128K RAM (factory expandable to 256K); 128K EEPROM expandable to 256K p. 15
Capacity
Up to 2,500 employees depending on memory option; up to 300 schedules, each with 8 time zones p. 17
Cable distances
RS232 under 50 feet (15 meters); RS485 up to 5000 feet (1500 meters), or 10,000 feet (3000 meters) with an ATS network booster; readers within 20 wire-feet p. 30
RS485 converter
One RS-232 to RS-485 converter supports up to 32 units over up to 1500m (5000 feet); needs its own 12VDC @ 500mA supply p. 32
Clock
Internal battery-backed real-time clock, estimated battery life 10 or more years; automatic daylight saving update p. 16, 17
Status LEDs
Alive, transmit, receive, DI_1 active, DI_2 active, 5V DC OK, 12V DC OK p. 16
Enclosure
Steel, with wall mounting holes and cable openings; on-board tamper switch for cover removal p. 16
Operating environment
0 to 43 degrees C (32 to 110 degrees F); humidity less than 95% non-condensing; indoor locations p. 30

What this manual walks you through

  • Choosing an indoor site near the door, away from electrical noise p. 30
  • Powering the unit from a plug-in power pack or through the network cable p. 31
  • Choosing cable and staying within wire length limits p. 32
  • Using ATS communication adapters, converters, port splitters, junction boxes and network boosters p. 32, 33
  • Wiring the plug-in screw terminal blocks p. 34
  • Wiring barcode, magnetic, proximity or keypad readers p. 35
  • Wiring a magnetic door sensor to a digital input p. 36
  • Wiring a door lock and an alarm to the relay outputs p. 37, 38
  • Setting the DIP switches for interface, door mode, reader type and unit address p. 39, 40
  • Setting the reader-type jumpers p. 41

Good to know

  • The unit is not designed for outdoor mounting exposed to weather, nor for wash down. p. 30
  • Both readers must be of the same type, and the board jumpers must match the reader type. p. 20, 41
  • Disconnect power and take ESD precautions before opening the enclosure. p. 34
  • If the clock battery ever needs replacing, the unit goes back to the factory. p. 16
  • When using the AccuComm program with default settings, configure AccuComm for 2 stop bits. p. 27

Questions this manual answers

What badge readers work with the Accu-Time Series 7000?

Barcode (code 39), magnetic stripe ABA Track II, clock-and-data proximity readers, or a keypad; both reader inputs must use the same type. p. 15, 27

What power supply does the Series 7000 need?

An unregulated 9-18 VDC source, nominally 12 VDC at 300 mA with no options, such as the ATS plug-in power pack. p. 31

How many Series 7000 units can share one RS485 network?

A single RS-232 to RS-485 converter supports up to 32 units on a network up to 1500 m (5000 feet). p. 32

How far can a reader be from the Series 7000?

Readers must be within 20 wire-feet of the unit. p. 30

How much current can the Series 7000 relays switch?

Each of the two form C relay outputs can switch 4-30 volts DC at 7 amps. p. 15

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. Purpose10
    1. Intended Audience10
    2. Structure10
    3. Document Conventions11
    4. Feedback13
  2. Chapter 1 Introduction14
    1. Technical Summary15
    2. Connectors, LEDS, Jumpers, and Switches18
    3. Operating Modes20
    4. Reset21
    5. Validation Table23
    6. Schedules24
    7. Door lock/ release operation (DO_1)24
    8. Anti- Passback25
    9. Standalone Mode26
    10. Host Communications27
  3. Chapter 2 Installation29
    1. Installation Guidelines30
    2. Connecting the Reader and DI/DO Wiring34
    3. Setting the DIP Switches39
    4. Setting the Jumpers41
  4. Chapter 3 Commands47
    1. Command Syntax48
    2. Command Index49
    3. General Commands51
    4. Employee File Handling Commands62
    5. Badge Masking and Validation Commands64
    6. Schedule File Handling66
    7. Bell Schedule File Handling70
    8. Interactive Commands72
    9. Controlling Relays DO_1, DO_274
    10. Messages Received From ACU77
    11. General Command Syntax Notes88
  5. Appendix A Minute Offsets89
  6. Appendix B Pinouts, Interfaces, and Switches91
    1. Pinouts91
    2. DIP Switches93
    3. Standard Reader Connections94
    4. Barcode Readers (ATS Weather Resistant 9001/ XX)97
3 more lines, from page 98 on
  1. Appendix C Terminal Addresses98
  2. Appendix D Sample Download File100
  3. Index102

From the PDF’s own bookmarks.

The whole text · 13 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 31-3
  2. Table of Contents4-13
  3. Chapter 1 Introduction14-28
  4. Chapter 2 Installation, pages 29 to 3729-37
  5. Chapter 2 Installation, pages 38 to 4638-46
  6. Chapter 3 Commands, pages 47 to 5547-55
  7. Chapter 3 Commands, pages 56 to 6456-64
  8. Chapter 3 Commands, pages 65 to 7365-73
  9. Chapter 3 Commands, pages 74 to 8274-82
  10. Chapter 3 Commands, pages 83 to 8883-88
  11. Pages 89 to 9789-97
  12. Pages 98 to 10198-101
  13. Index102-105

The file

Revision and size

Part no.MANU7000-01h
Revisionprinted August 24, 2004
PublisherAccu-Time Systems, Inc.
Pages105
PDF1.2 MB
TextText from the PDF itself.
MANU7000-01h

The first pages · 3 of 105

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 105
Page 2
Page 2of 105
Page 3
Page 3of 105