For the Accu-Time Series 7000
Page 14
Chapter 1
Introduction
The Series 7000 Access Control Unit (ACU) provides a means of controlling the secure access of individuals through internal and external doors of a building. Typical installations dedicate one ACU to each door, which provides the maximum flexibility and security. The Series 7000 ACU can often be mounted in the ceiling space above a particular door with the door lock, readers, and alarms wired to it. The Series 7000 provides support for anti-passback control that prevents employees passing badges to colleagues to gain multiple access through a door. In addition, the digital input connections can be used to automatically trigger alarms if doors are left open or are forced open without a valid badge. A choice of operating modes allows the Series 7000 to be used in a number of different types of installations: • Stand-alone mode allows badges to be added and deleted from each controller using a master badge,. • Off-line mode provides local intelligence at the controller to determine access rights for individual badges. A PC is used to collect transaction data and download updated validation tables at set intervals. • On-line mode maintains all of the intelligence at the PC with validation of badges being made in real time.
Accu-Time® Series 7000 Access Control Unit User’s Guide
1-1
Page 15
This section summarizes the features of the Series 7000 ACU. DI/DO:
Two digital inputs (DI_1 and DI_2). Dual DI 2 x 5terminal screw down connectors (+5V Vcc, DI+, DI–, ground, shield.) Detects closure of contacts between sense inputs. Two digital form C relay outputs (DO_1 and DO_2), selectable normally open (NO) or normally closed (NC). Dual DO 2 x 5-terminal screw down connectors. (+12V, common, normally closed, normally open, ground.) Relay outputs can switch 4-30 volts DC @ 7 amps.
Readers:
Connections for two readers, both of which must be the same type. Unique ID for each reader. Support for barcode, magnetic Track 2, “clock and data” proximity, and keypad. Circuitry for reader LEDs (3 individual and tri-state). Barcode:
Infrared or visible red reader. Weatherproof or non-weatherproof versions.
Magnetic Stripe:ABA Track II. Weatherproof or non-weatherproof versions. Proximity:
Weatherproof or non-weatherproof versions using clock-and-data protocol.
Keypad:
Vandal-proof external keypad for PIN entry. Available with integrated magnetic stripe reader for added security.
COMM:
RS232 and RS485 interfaces. Single RJ45 socket for direct RS232 connection to PC. Two RJ45 sockets for wiring a multi-drop RS485 network.
Microprocessor
Enhanced 8051 derivative, 512K PROM (firmware storage), 128K RAM (factory expandable to 256K).
Memory:
128K EEPROM expandable to 256K, infinite time retention in absence of power. Contents of EEPROM written to RAM for fast access, then written back just before a power-down or reset. Events log rate: (Event log capacity * 100,000) / (365 * product life time) The events EEPROM has a capacity of 8,000 event logs, so it can log up to 219,000 events a day for a 10 year product lifetime.
Accu-Time® Series 7000 Access Control Unit User’s Guide
1-2
Introduction
Technical Summary
Page 16
12VDC @ 1A. Standard inline power socket (2.5 / 5.5mm, center +V).
Output Power:
12VDC power source for powering door release strikes. Power available is 1A, less the amount drawn by the Series 7000 itself.
Modes:
Networked online, interactive, or stand-alone.
Battery Backup:
External UPS with charger circuit. (Not currently available.)
Real-Time Clock:
Internal battery backed real-time clock for date/time stamping. Estimated battery life is 10 or more years. (Return unit to factory if replacement is ever required.)
Data Backup:
EEPROM.
Construction:
Steel enclosure with wall mounting holes and openings for cable entry.
Diagnostics:
Eight on-board LEDs show status of readers, DI/DO, network, and power. Table 1-1 gives the meaning of each LED.
Table 1-1: Series 7000 Diagnostic LEDs LED ID
Meaning
LED1 blinking Red Alive (ACU functioning properly)
Switches/ Jumpers
LED2 Green
ACU transmitting via RS232 or RS485 port
LED3 Yellow
ACU receiving via RS232 or RS485 port
LED4 Red
DI_1 active
LED5 Red
DI_2 active
LED6 Yellow
5V DC OK
LED7 Green
12V DC OK
Beeper:
An on-board single tone beeper used for: Double short beep (a “good beep”). Single long beep (a “bad beep”).
Test Switch:
On-board slide switch enables ACU test mode. (To enable test mode, slide to right away from RJ45 connectors.)
Tamper Switch:
An on-board tamper switch that operates when the case cover is removed. DIP switch 1, position 2, enables the tamper switch feature.
Accu-Time® Series 7000 Access Control Unit User’s Guide
1-3
Introduction
Input Power:
Page 17
Firmware
Jumpers
Select types of readers. One jumper per reader. Place jumper on top two of three pins for magnetic or proximity reader or for a keypad, on bottom two of three pins for barcode reader. See Figure 1-3. See also Table B-5, “DIP Switch 2 Settings,” on page B-3. (In current version of Series 7000 ACU, both readers must be of the same type.)
Memory Loop:
Auto-memory loop-around for offline use without need to download.
Anti-Passback:
Prevention of multi-employee badge use.
Validation:
Employee badge validation and schedule validation.
DI/DO:
Full support for dual DI and DO operation.
Comm Management:
Auto revert to offline mode if network fails.
Maximum Employees: Up to 2,500 depending on memory option.
Power Fail
Employee Schedules:
Up to 300 schedules, each with 8 definable time zones.
Date Settings:
Automatic daylight time savings update.
In the event of a power fail: • No backup battery installed - The real time clock settings are preserved by the dedicated 3V button battery. The ACU will not function, but all transaction and configuration data will be maintained in the EEPROM. • Backup battery installed - The ACU continues to function. If connected, the power fail input causes a status message sent to the host computer. (Not currently supported).
Accu-Time® Series 7000 Access Control Unit User’s Guide
1-4
Introduction
Intelligent Programming:Configuration of ACU through “intelligent” badge swipes for badge enrollment, badge disable, relay activation time, badge check, etc.
Page 18
Connectors, LEDS, Jumpers, and Switches
Refer to Figure 1-1 and Figure 1-2 for the locations of connectors, switches, jumpers, and LEDs.
Figure 1-1:Series 7000 Network Connectors and Status LEDs 1
2
3
RS485 IN
RS485 OUT
RS232
Network/Comms
4
Introduction
Alive TX RX DI1 DI2 5v 12v
5
1. RS485 In – for multi-dropping ACUs 2. RS485 Out – for multi-dropping ACUs 3. RS232 – for direct PC serial line connection 4. Status LEDs (See Table 1-1) 5. Earth ground standoff (on bottom of enclosure)
Accu-Time® Series 7000 Access Control Unit User’s Guide
1-5
Page 19
Figure 1-2:Series 7000 Switches and Connectors 4 2
6
7
3 TEST
USE
15
8
17
9
10
11
12
16
13
14
1. RS485 In 2. RS485 Out 3. RS232 4. DIP switch 1 5. DIP switch 2 6. Tamper switch 7. Test switch 8. 12V power 9. Relay 1 (DO_1) 10. Relay 2 (DO_2) 11. DI_1 12. DI_2 13. Reader 0 14. Reader 1 15. Battery status monitor (for future use) 16. Jumpers for types of readers (See Figure 1-3 and also Table B-5) 17. Grounding stud on enclosure (6-32 thread) Accu-Time® Series 7000 Access Control Unit User’s Guide
1-6
Introduction
1
5
Page 20
Figure 1-3:Jumpers to Select Types of Readers This position for Magnetic or Proximity Reader or Keypad
3 2 1
This position forBarcode Reader
Jumper for Jumper for Reader 1 Reader 0 Both readers must be of the same type.
Operating Modes
The ACU can operate in three modes: • Test Mode. • Standalone Mode.
Test Mode
To enable test mode, set DIP switch 1 position 1 to ON and set the test mode slide switch (Figure 1-2 item 7) to ON. (Slide to the right, away from the RJ45 connectors). The ACU acts as follows when in this mode: • If a card is swiped through a reader wired into reader 0 or reader 1 and the card data checks (parity and LRC) are valid, both readers’ green LED pinout on the reader connectors (pin 5) will turn on for 1 second and a “good beep” will sound. • If DI_1 active, DO_1 active. • If DI2 active, DO_2 active. • If DI_1 inactive, DO_1 inactive. • If DI2 inactive, DO_2 inactive. • If a card is swiped through a reader wired into Reader 0 or Reader 1 and the card data checks (parity and LRC) are not valid, both readers’ red LED pin out on the reader connectors (pin 6) will turn on for 1 second and a ‘bad beep’ will sound.
Accu-Time® Series 7000 Access Control Unit User’s Guide
1-7
Introduction
• Online Mode (RS485 Multidrop Network or RS232).
Page 21
Standalone Mode
Standalone mode is selected by setting DIP switch 1 position 8 to OFF. This mode disables the RS232 and RS485 ports.
Online Mode
Online mode is selected by setting DIP switch 1 position 8 to ON. In this mode, the RS485 or RS232 ports are enabled. The ACU can communicate with a host PC that is connected to either port and running software compliant with the ATS polled protocol.
On Line Mode, Dual Door
Online mode is selected by setting DIP switch 1 position 8 to ON. In this mode, the RS485 or RS232 ports are enabled. The ACU can communicate with a host PC that is connected to either port and running software compliant with the ATS polled protocol.
Reset
The Reset DIP switch enables a reset to factory defaults. If the Reset DIP switch (position 3 of DIP switch 1) is set to ON, the ACU resets parameters as follows: • Reset the RS232 and RS485 network at 9600,8,1,N. (9600 baud, 8 data bits, 1 stop bit, no parity). • Reset Queue pointers. • Erase validation Table. • Erase Schedule Table. • Set DO_1 activation time to 1 second. • Set DO_2 activation time to 10 seconds. • Set DI_1 time out disabled (000). • Set DI_2 time out disabled (000). • No badge filtering. • Set download ID to “Not Set.” • Set Beeper Enable.
Accu-Time® Series 7000 Access Control Unit User’s Guide
1-8
Introduction
Dual door mode is selected by DIP switch 1 position 6 to ON. In this mode, a door lock can be connected to each relay and two door sensors connected to each digital input. On swiping a valid badge on reader 0, relay 1 will activate according to the timeout set. Similarly, when swiping a valid badge on reader 1, realay 2 will activate.
Page 22
• Enable validation table testing. • Disable mask testing. • Set validation Positive. • Reset badge mask. • Disable anti-passback. • Reset daylight saving. • Reset the bell schedule. • Set the date to January 1, 2000.
Introduction
• Set master badge default number to 070261150168.
Accu-Time® Series 7000 Access Control Unit User’s Guide
1-9
Page 23
The ACU keeps in memory a validation table, where the badge numbers (up to 12 digits each) and the schedule IDs (up to 100) are stored. Up to 2500 badges can be stored in the validation table (2500 users). The ACU keeps only the first 2500 users loaded.
Validation Table Online Download
If online mode is selected, the ACU gets the validation table from a host PC using the serial port. You use commands from the host such as LEE01, LEC01, and LED01 to load records into the ACU.
Standalone Validation Table
In standalone mode, the ACU’s validation table is set up locally instead of being downloaded from a remote host.
Single Card Add/ Disable/Enable
In standalone mode it is possible to add or remove a badge from the validation table. You must use a special master badge access card to put the ACU in this mode. To add/disable/enable a badge: • Swipe the access card, then swipe the employee badge. • If the employee badge is not in the validation table, it will be added and enabled (access allowed). • If the employee badge is already in the validation table and enabled, the badge will be disabled (access not allowed). • If it is already in the validation table and disabled, the badge will be enabled. • After swiping the a card to add or delete the badge, test the card to make sure it does (or does not) open the door. • The master badge access card default is 070261150168. Notes: • The number of badges in the validation table is limited to 2500, and disabling a badge does not delete it from the validation table. • All employees added in this way have an open schedule. Scheduling is not available.
Accu-Time® Series 7000 Access Control Unit User’s Guide
1-10
Introduction
Validation Table
Page 24
Schedules
Door lock/ release operation (DO_1)
The ACU keeps in memory a schedule table, where the schedule IDs (up to 100) and the schedule zones (up to 800) are stored. Each schedule have 8 zones. The ACU keeps only the first 100 schedules loaded. You use commands such as LSE01 and LSC01 to download schedule information from the host to the ACU.
The DO_1 relay is typically connected to an electric door lock. In normal use, operation proceeds somewhat as follows: Swipe a card to enter a badge number. • The ACU recognizes a “good swipe” when the data received from the readers is valid according to the parity and LRC card check, and if the number of digits does not exceed 12. The badge number is accepted and will be processed.
• If the number of digits exceeds 12, the ACU recognizes a “bad swipe.” The badge number is rejected and will not be processed. To open the door, the badge has to be validated. • If the badge number is in the validation table and inside its schedule zone, the badge is valid. • If the badge number is in the validation table but outside its schedule zone, the badge is not valid. • If the badge number is not in the validation table, the badge is not valid.
“Good Swipe” and “Badge Valid”
The green LED pin out on the reader connectors is set on for 1 second. A “good beep” sounds if enabled and the DO_1 is active for a pre-set time.
”Good Swipe” and “Badge Not Valid”
The yellow LED pin out on the reader connectors is set on for1 second and a “bad beep” sounds if enabled.
”Bad Swipe”
The red LED pin out on the reader connectors is set on for 1 second and a “bad beep” sounds if enabled.
Accu-Time® Series 7000 Access Control Unit User’s Guide
1-11
Introduction
• The ACU recognizes a “bad swipe” when the data received from the readers is not valid, when the parity or LRC card check fails. The badge number is rejected and will not be processed.
Page 25
Badge Swipe and Alarm Logging
Every time a “good swipe” occurs, the ACU stores in memory: • The badge number • The date • The time • Access permit/denied decision The ACU also logs the alarm occurrences (tamper, DI_1, and DI_2) and the battery status (low battery and on battery) With 1Mbits of storing memory, the ACU can store the last 8000 events. If the ACU is permanently polled, the host PC will receive the last swipe. If the ACU is not polled for any reason: • The ACU will remember the last polled data.
AntiPassback
The validation table is stored in RAM for fast access and includes a PRESENCE flag to identify that a badge has been swiped in or swiped out. If enabled, the anti-passback feature works as follows (reader 1 – outside): • A “good swipe” in reader 0 sets the PRESENCE flag to OUT and the badge is valid. • If the presence flag is OUT and a “good swipe” occurs in reader 1, the PRESENCE flag is set to IN and the badge is valid. • If the presence flag is IN and a “good swipe” occurs in reader 1, the badge is not valid. Note: When the ACU resets (power fail or startup), all the PRESENCE flags are set to OUT.
Accu-Time® Series 7000 Access Control Unit User’s Guide
1-12
Introduction
• When the ACU is polled again, the host will receive the data from this last polled data, one at a time at each poll, up to the last “good swipe.”
Page 26
Standalone Mode
When the ACU is installed as a stand-alone ACU, a master card is used to add and delete users (badge IDs) to/from the ACU. The default master ID badge number is 070261150168. If needed, the ACU can initially be connected to a PC communications port and employee validation files can be downloaded (according to the ATS protocol) using the relevant commands as outlined in the command set. Once this has been done, the ACU can be switched into stand-alone mode and employees can now swipe and use the ACU as normal.
You can use the master badge for setup only when the ACU is in standalone mode. The master badge can be barcode, magnetic stripe, or proximity format, depending on the type of reader that is connected. If the reader being used supports tri-state LEDs, the LEDs will provide visual indicators of the ACU state. If the master badge is swiped on reader 1 or 2, the ACU will enter intelligent badge set-up mode and the readers will show an illuminated yellow LED. To add a new badge ID to the ACU’s validation table, swipe a new card after the master card swipe. If successfully added, the ACU will sound a good beep and flash the reader’s green LED. To delete a current badge, swipe the master badge followed by the existing badge you want to remove from the ACU. The number for the master badge can be changed from the default number using the LSA01 command.
Accu-Time® Series 7000 Access Control Unit User’s Guide
1-13
Introduction
Using the Master badge
Page 27
Host Communications There are a number of host software utilities available from ATS that are intended to be used by software developers to assist with the creation of access control application software. The scope of this manual does not cover in detail the use of these utilities. Contact Accu-Time Systems or your local ATS representative if you would like a copy of any of these utilities.
AccuComm/ Test Program
ATS can provide upon request AccuComm, a sample application program. The program uses both the ATS DLLs and third party controls to manage communications between a PC and a Series 7000 ACU. It provides the means to poll, download, set time/date, and send messages to the Series 7000 ACU.1
Dynamic Link Library Files
Dynamic Link Libraries (DLLs) are available to run within an application to manage the protocol handling between a PC and a Series 7000 ACU. Currently, the following .DLLs are available: atspol32.dll atstcp95.dll atstcp32.dll
Employee Identification
Serial communications for Windows 95/98/2000 TCP communications for Windows 95/98 TCP communications for Windows NT
Employees are identified, in a database, through the use of a unique set of alphanumeric characters. These characters can be presented on employee badges as bar code, magnetic stripe, or Proximity devices (Indala, Hughes, Sensor), or a combination of unique numbers and a biometric template. The ACU supports all of these technologies. The two most commonly used encoding techniques are bar code and magnetic stripe, described below. • Bar Code: Bar coded employee badges probably represent the lowest cost, most easily produced, and most flexible of the badge types. Security from duplication can be provided through the use of an opaque covering over the bar coded area. Infra-red light from the barcode reader can penetrate this covering and read the bar code. The Series 7000 ACU currently supports only code 39 format. If other codes are needed, please consult factory.
1 The Series 7000 serial ports default to 9600 baud, 8 character bits, 1 stop bit, no parity.
Because of a quirk in Accu-Comm’s operation, however, you should configure AccuComm for 2 stop bits when you use it to control a Series 7000 with default settings. Accu-Time® Series 7000 Access Control Unit User’s Guide
1-14
Introduction
Documentation describing the ATS proprietary protocol is available for software developers who need to manage the communications between a PC and a Series 7000 ACU.
Page 28
• Magnetic Stripe: Magnetically encoded badges look very similar to a standard bank issued credit card. Although there are physically three different magnetic “tracks” that can be encoded and read, ABA track 2 is most common and therefore recommended. Security (difficult to copy or modify) and higher data density (the number of characters and/or numbers per inch) are the main appeal of this technology. The magnetic strip or stripe is applied by the card manufacturer therefore no specifications are provided. Consult with the factory if you require Track 1 or Track 3 support. • Proximity: This technology uses RF (radio frequency) to activate a passive chip embedded in a card or a key fob, which contains an alphanumeric code representing the employees number. As the reader radiates a field, the badge or key fob does not have to actually make contact with the reader. Proximity badges/key fobs are almost impossible to copy, so they are quite often the preferred technology for high security access control applications
Introduction
• Keypad: A keypad is the simplest and probably the least secure of all input technologies. Each keypad has a calculator key layout with 0 – 9, enter and clear. A PIN number is entered into the keypad followed by the Enter key to complete the entry.
Accu-Time® Series 7000 Access Control Unit User’s Guide
1-15