Accu-Time Series 7000 Access Control Unit User's Manual: Chapter 2 Installation, pages 29 to 37

Pages 29 to 37 of 105, from Accu-Time Series 7000 Access Control Unit User's Manual

The original document is the PDF (1.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Accu-Time Series 7000

Page 29

Chapter 2

Installation

Figure 2-1 shows a typical Series 7000 installation scenario.

Figure 2-1: Typical Series 7000 Installation 12VDC Alarm (DO_2)

RS232/RS485 to host PC ACU

Magnetic switch (DI_1)

Magnetic door lock (DO_1)

Accu-Time® Series 7000 Access Control Unit User’s Guide

Reader 1 (Reader 2 on other side of door)

2-1

Page 30

Installation Guidelines

Environmental Considerations

The terminals and other data collection products manufactured by ATS are microcomputers and should be treated accordingly. Exposure to extreme heat or cold, airborne contaminates, electrically noisy environments, poor power, or any other hostile parameter can reduce the device’s performance and introduce data errors. The following information is provided as a set of guidelines to help you understand the basic issues associated with the installation of an access control system.

When choosing a site for installing the ACU, consideration should be given to the environment, the cable distance from the host computer, and where the power source will be located. The ACUs have been designed to be durable, industrialgrade units that can endure harsh environments, but they are not designed to be mounted outside exposed to the weather, nor can they be washed down. Select an interior location that is close to the door or other feature to be controlled, such as in the ceiling space above the door, ensuring that there is sufficient space around the unit to provide access for connecting the power supply and routing the cables.

Temperature: 0 to 43 degrees C (32 to 110 degrees F) Humidity: less than 95% (non-condensing)

Mounting

The ACU(s) should be located in areas that permit ease of employee access while remaining as close to the controlling computer as possible. This reduces the chances of noise coupling into the data lines and may let you run a single ACU using a simple RS-232 interface (under 50 feet, or 15meters). Should longer distances be required, an RS485 interface will support connections of up to 5000 feet (1500 meters), or up to 10,000 feet (3000 meters) with an ATS network booster. At longer distances, issues of cable selection, ATS port splitters, ATS junction boxes, and AC outlets will become more critical. The readers (barcode, magnetic, or proximity) must be located within 20 wire-feet of the ACU. The ACU is typically mounted on a wall or other vertical surface using the two keyhole mounting holes on the back plate of the unit. The mounting template shown in Figure 2-9 gives dimensions and hole spacing. To avoid electronic or electrical noise, take care when locating both the ACU and the routing of cables to the ACU. Some common noise producers include elevators, fluorescent lighting, large electric motors, commercial freezers, air conditioning systems, arc welders, and conveyor systems, which should all be avoided.

Accu-Time® Series 7000 Access Control Unit User’s Guide

2-2

Introduction

Take into consideration the likely temperature conditions of the chosen location to ensure that the temperature will not exceed the operating limits of the ACU:

Page 31

Power

The ACU is designed to operate from an unregulated 9-18 VDC power source. (nominal 12 VDC @ 300 mA with no options). Although concerns over the quality of the supplied AC power (high line, low line, brown outs, surges, spikes, etc.) are still important, the transformer in the AC to DC power pack and the tolerance of an unregulated 9-18 volt output gives some degree of isolation from these problems. Ideally, a clean, dedicated AC line should be provided to power the ACU(s) in the network. If a dedicated line is not available, the cleanest line possible, with no electromechanical devices on it, should be used. Power can be supplied in two ways: • Through two extra conductors in the 8-conductor RS232 or RS485 cabling supplied by Accu-Time Systems, Inc. You can supply power to these conductors through a power socket built into a DE-9-RJ45 comm adapter, available from ATS. Many factors, such as each terminal’s load, the wire gauge, and the length of the wiring must be considered when using this approach, especially in a multi-drop environment. Consult ATS for guidance.

A suitable plug-in power pack similar to Figure 2-2 is available from Accu-Time Systems, Inc. Ensure that a conventional 120VAC wall outlet (220VAC in Europe and other areas, check local electrical code requirements) is available to accept the power pack assembly. The output cable from the power pack, typically 6 feet (1.8 meters) long, will plug into either the power socket on the PC board (Figure 1-2 item 8) or into the power socket on a DE-9-RJ45 comm adapter. The cover of the ACU is held in place by four #2 Phillips head screws. Remove the screws and lift off the cover to access the power socket on the PC board.

Figure 2-2: Typical 12V Power Pack

Cabling

Usually three things dictate what kind of cable will be used. The first is the environment in which it will be used. (Cable runs, length of pull, type of noise expected, fire/building codes etc.). Second is the communications interface being used (RS-232 or RS-485) and the need for local or remote power. Third is the cost per meter/foot.

Accu-Time® Series 7000 Access Control Unit User’s Guide

2-3

Introduction

• Through the power socket on the ACU’s PC board (Figure 1-2, item 8).

Page 32

You should use RS232 or RS485 cabling with correct twisted pairs. Category 5 cabling, although unshielded, will work in most non-industrial environments, but it is not recommended. Be sure the distance from the terminal’s location to the host computer does not exceed the wire length limitation of the connection type you plan to use. These limits are shown in Table 2-1.

Table 2-1: Wire Length Limitations Maximum Terminal-to-Host Distance

RS232

50 wire-feet

RS485

Combined terminal/host drop points should not exceed 5,000 wire-feet.

Ethernet 10BASE-T

328 wire-feet (100 meters) from terminal to Ethernet hub or switch

The accessories listed in this section are available from ATS. They can assist you in setting up your overall system network. Communications Adapter This device lets you plug into the back of a computer with either a DB-25 connector or a DE-9 connector on one end of the adapter and a RJ-45 connector on the other. This adapter also has a power socket for connecting a 12V power pack. (See Power on page 2-3.) RS-232 to RS-485 Converter This device converts RS-232 signals to 4 wire, differentially driven RS-485 signals. It is an active device and requires a seperate12VDC@ 500mA power supply. A single converter can support up to 32 Access Control Units over a network up to 1500m (5000 feet) in length. Port Splitter This passive 4 port device is designed to provide a network insertion point for up to 2 Access Control Units (ACUs). If the port splitter is inserted at the end of the network, 3 ACUs may be added. Connections into and out of the port splitter are made via RJ-45 connections. Network Junction Box This passive device provides three 8-position barrier strips to allow network wiring to be brought in, with a star configuration out to the rest of the network. Further, it has four RJ-45 ports for multi-dropping ACUs and a DC power input that can feed all four RJ-45 ports. It is supplied with tie wraps for network cable strain relief.

Accu-Time® Series 7000 Access Control Unit User’s Guide

2-4

Introduction

Cabling Accessories

Connection Type

Page 33

Network Junction Box Junior Similar in function to the above, the Junior only has a single 8 position barrier strip (for bringing the network cable in and out); two RJ-45 ports for multidropping ACUs, and a DC input which can provide power to both RJ-45 ports. It also comes equipped with tie wraps for strain relief of the network cable. Network Booster This active device is used to “boost” or amplify signals in a second 1500m (5000’) segment of an RS-485 network. It provides two 8-position barrier strips, the first for bringing in the first 5000 feet, and the second for the next 5000 feet. It also provides four RJ-45 ports for multi-dropping to ACUs. A 12VDC @ 500mA power supply is required to drive the booster. Strain relief tie wraps are included

RS232

Figure 2-7 shows a typical wiring setup for an RS232 installation. Each ACU connected to the host PC requires its own comm port.

RS485

Figure 2-8 shows a typical wiring setup for an RS485 installation. ACUs connected using RS485 wiring can be “daisy chained” together and use a single host PC comm port.

Accu-Time® Series 7000 Access Control Unit User’s Guide

2-5

Introduction

Network Terminal Block This is a plastic, wall mounted device that provides 8 screw-down terminals for spade lug input connections with a single RJ-45 output. It is used to connect an ACU to the main network cable. Mounting hardware is included.

Page 34

Be sure no power is connected to the ACU. The cover of the ACU is held in place by four #2 Phillips head screws. Remove the screws and lift off the cover to access the interior. Take appropriate electrostatic discharge (ESD) precautions whenever you open the enclosure and work around the PC board. Although it is possible to connect the wiring for the digital inputs and outputs, the readers, and the power monitor in place, ATS does not recommend doing so. The screw-down wiring terminals are all of the form shown in Figure 2-3. The terminal blocks are in two pieces that plug together. The part with the screw terminals will unplug from the part that is soldered to the PC board. To unplug a block, place your fingernails behind the ridge in the block that is just behind the line of screw heads and pull straight forward, away from the PC board. The front portion of the block containing the screw terminals should unplug form the rear portion. After you unplug a terminal block, be sure the terminal screws are unscrewed all the way. Strip approximately 5/16” (8mm) of insulation from the ends of the wires that go to the device to be connected to that set of terminals. Push the ends of the wires from the device into the rectangular openings in the front of the block below the screws, as far as the wires will go. Then tighten the screws. Be sure you screw down on the wire, not on the insulation. Also be sure you don’t mix up left and right by inverting the block. When the wires are in place, align the front portion of the terminal block with the mating socket on the PC board, and snap the block back together by squeezing the halves between your fingers.

Figure 2-3: Wiring a Terminal Block Tighten screw to secure wire Strip 5/16”

Pu sh in

PC to k e t n g i oc P lu ar d s bo

Accu-Time® Series 7000 Access Control Unit User’s Guide

2-6

Introduction

Connecting the Reader and DI/DO Wiring

Page 35

Refer to Standard Reader Connections on page B-4 for tables of pinouts used for readers supported by the Series 7000 ACU. Find the types of readers you have, and connect their wiring to the reader terminal blocks in the ACU. Table 2-2 identifies the ACU reader/keyboard pin numbers and summarizes the connections required.The current version of the Series 7000 ACU expects both readers to be of the same type.

Table 2-2: ACU Reader/Keypad 0 and 1 Connections Pin Number

Function

Mag / Prox

Barcode

Keypad

1

Shield

Shield

Shield

Shield

2

Ground (0V)

Ground (0V)

Ground (0V) Link to pin 10

Ground (0V)

3

+9V

+9V

Not Connected

+9V

4

Not Connected

Not Connected Not Connected

A – Row 1

5

Green LED

Green LED

Not Connected

B – Row 2

6

Red LED

Red LED

Not Connected

C – Row 3

7

Yellow LED

Yellow LED

Not Connected

D – Row 4

8

Not Connected

Not Connected Not Connected

Not Connected

9

Data

Data

Data

2 – Col 2

(Open/Collector) 10

Media Detect

Card Present

Link to pin 2

3 – Col 3

11

Clock

Clock

Not Connected

1 – Col 1

+5V

+5V

+5V

(Open Collector) 12

+5V a.

Pin 10 of reader 1 is the exit button input. This is an active low input b.

If the anti-passback feature will be used then reader 0 should be connected to the IN side of the door and reader 1 to the outside.

c.

The LEDs should be pulled to Ground to light LED (20ma max.)

d.

Pin 10 (Media Detect) goes low (0V) during data transmission.

Accu-Time® Series 7000 Access Control Unit User’s Guide

2-7

Introduction

Wiring the Readers

Page 36

The digital inputs each have five terminals: DI–, DI+, Vcc (+5V), shield, and ground. Table 2-3 identifies the pin numbers for the digital inputs.

Table 2-3: ACU DI Connections Pin Number

Description

1

Shield

2

Ground

3

DI -

4

DI +

5

Vcc (+5v)

In an inactive state, DI– should be pulled low (connected to ground) and DI+ pulled high (connected to Vcc). If either of those connections is broken, the digital input will signal alarm state. For the installation shown in Figure 2-1, connect a normally open magnetic switch between DI– and ground of DI_1. Put a jumper between DI+ and Vcc. (Or, you could put the magnetic switch between DI+ and Vcc, and the jumper between DI– and ground. The effect is the same.) Connect the wire’s shield, if any, to the shield terminal.

Digital IN 1 (DI_1) Vcc

DI+

DI-

Gnd

Introduction

Wiring the Digital Inputs (DI_1 and DI_2)

Shd

Magnetic Door Sensor

When contact is broken, DI_1 enters alarm state and can trigger DO_2 to sound alarm. In the installation being described, DI_2 is not used. Place jumpers between DI– and ground, and between DI+ and Vcc, of DI_2 to disable it.

Digital IN 2 (DI_2) Vcc

DI+

DI-

Gnd

Shd

DI_2 not used. DI+ and DI- connected to power and ground to prevent ACU from entering alarm state.

Accu-Time® Series 7000 Access Control Unit User’s Guide

2-8

Page 37

Wiring the Digital Outputs (DO_1 and DO_2)

The digital outputs each have five terminals: ground, normally open, normally closed, common, and 12V. Table 2-4 identifies the pin numbers for the digital outputs. Figure 2-4 clarifies the relationship of the digital output connections.

Table 2-4: ACU DO Connections Pin Number

Description

1

+12v

2

Common

3

Normally Closed

4

Normally Open

5

Ground

Figure 2-4: Digital Output (Relay) Connections Normally Closed (NC) Common

Wiring the Door Lock

In the installation shown in Figure 2-1, DO_1 is connected to an electric door lock. The figure below shows one way to make the connection:

Relay 1 (DO_1) Gnd

NO

NC Com 12V

Magnetic Lock

12VDC magnetic lock. Connection normally closed (powered to maintain locked state). In that wiring example, the power for the door lock is being taken from the 12V terminal on DO_1. Figure 2-5 shows an alternative method of powering the door lock from an external source for a voltage other than 12VDC or if the lock requires more power than can be supplied by the 12V relay connection.

Accu-Time® Series 7000 Access Control Unit User’s Guide

2-9

Introduction

Normally Open (NO)