Page 65
of the badge will be tested to see if its valid, such as, is it a number, is it a character, is it either a number or a character, or test to see if it is a specific character.) • If the badge is to be tested against the employee file, is it negative or positive validation. Positive validation will allow the badge if it is present in the employee file. Negative validation will allow the badge if is NOT present in the employee file. Example: LEB01110000000000????000^ Requests validation against the employee file, requests mask checking, and positive validation. The mask requires zeros in the first eight badge number positions and any character in the last four positions. No schedule testing is to be performed.
Accu-Time® Series 7000 Access Control Unit User’s Guide
3-19
Page 66
Schedule File Handling LSE01
This section lists commands used to set up and maintain employee schedule files.
Erase All Schedules Syntax:
LSE01rs Arguments: None. Discussion: The LSE01 command erases all schedules loaded in the ACU. Note: There may be a delay when using this command because of the time required to erase all memory locations reserved for all schedules. It may be faster to use the LSC01 command and erase individually. Example: LSE01^ Erases all schedules.
LSB01
Set Schedule Start Date
Syntax: LSB01YYMMDDrs Arguments: YY - Two-digit year MM - Two-digit month DD - Two-digit day Discussion: This command sets the schedule start time at 00:00 the specified day. All start and stop zones are in minutes offset from that time. Example: LSB01030420^ Sets the schedule start time to April 20, 2003, 00:00:00. Accu-Time® Series 7000 Access Control Unit User’s Guide
3-20
Page 67
LSC01
Load Schedules Syntax: LSC0nnn_bbbbbeeeeers LSC01nnn_bbbbbeeeee_bbbbbeeeee...rs (n.b. _ represents a space character, which must be present.) Arguments: nnn - Schedule identifier number, 001 through 999. bbbbb - Beginning zone time, minutes offset from schedule start date. eeeee - Ending zone time, minutes offset from schedule start date. Discussion: The LSC01command defines a schedule and assigns beginning and ending times (time zones) between which an employee using that schedule will be allowed to use the ACU. If more than one zone is required for a schedule, then those times can be added to the argument string (see example below). When loading multiple schedule zones with the LSC01 command, the maximum length of the message must not exceed 250 characters. Only one schedule at a time can be loaded with an LSC01 command. The number of zones can vary from schedule to schedule The same schedule can be used for different employees. The space (shown as _ ) between nnn and bbbbb is reserved for future use. Also, when specifying multiple zones for a schedule there must be a space before the next start time. Example: Schedule number 1 End time zone 1 End time zone 2
LSC01001 0047300997 0218302437rs
Begin time zone 2 Begin time zone 1
Accu-Time® Series 7000 Access Control Unit User’s Guide
3-21
Page 68
The schedule shown in the example allows an employee to swipe between 473 minutes from the schedule start date (473 minutes = 7 hours 53 minutes or 7:53am) and 997 minutes (4:37pm) (zone 1), and between 12:23am and 4:37pm the next day (zone 2). A maximum of 300 schedules can be loaded each with 8 zones (1 zone = start time and stop time) Appendix C provides a minutes-to-hours conversion table to assist in calculating schedule times. Auto-schedule If a schedule is set up and used for a week and not re-downloaded at the end of the week, then it will automatically be re-used and continue for the next week based on the original zones.
LSD01
Delete Individual Schedule Syntax: LSD01nnnrs Arguments: nnn - Number of the schedule to delete. Discussion: To delete an individual schedule, specify the schedule number with no zones after it. The schedule will be deleted. Example: LSD01031^ Deletes schedule 31.
LHO101
Load Holiday Schedules Syntax: LHO101abcdefgrs Arguments: abcdefg - Each letter denotes a day of the week: a = Sunday, b = Monday, c = Tuesday, etc. Each letter can be set to zero or 1. Setting to 1 will place the badge on holiday that day, that is, will not allow access. Setting to zero will use the badge’s normal schedule if one exists. Discussion:
Accu-Time® Series 7000 Access Control Unit User’s Guide
3-22
Page 69
The holiday command lets you set a particular badge “on holiday” for particular days during the current week irrespective of its current schedules. The holiday command overrides any existing schedule for that badge. Example: LHO1011000011^ Mark badge number as “on holiday” for Sunday, Friday, and Saturday.
Accu-Time® Series 7000 Access Control Unit User’s Guide
3-23
Page 70
Bell Schedule File Handling LBE01
This section describes commands used to set up and maintain bell schedule files.
Erase All Bell Schedules Syntax: LBE01rs Arguments: None. Discussion: The LBE01 command erases all bell schedules loaded in the ACU. Example: LBE01^ Erases all bell schedules.
LBC01
Load Bell Schedules Syntax: LBC01dmmmm00rs LBC01dmmmm00mmmm00...rs Arguments: d - Day of week to assign schedule to:
0=Sunday, 1=Monday, 2=Tuesday, 3=Wednesday, 4=Thursday, 5=Friday, 6=Saturday. mmmm - Minutes past midnight to activate the DO. 00 - Two digit zero fill. Use the LPB03 command to specify the amount of time to activate the DO. Discussion: The bell schedule command gives you a way to activate the DO_2 output port at a specified time during the day. The load bell schedule command loads for a particular day, that days schedule.
Accu-Time® Series 7000 Access Control Unit User’s Guide
3-24
Page 71
You can define up to 32 bells per day. To load more than one bell schedule per day, specify the starting times (each with a two-digit zero fill) one after the other in the command line string. If one or more of the arguments is invalid, the command is ignored. Example: LBC010087000090000....^ Assigns to Sunday (0) a bell schedule of 2:30pm (870 minutes after midnight) and 3:00pm (900 minutes after midnight).
Accu-Time® Series 7000 Access Control Unit User’s Guide
3-25
Page 72
Interactive Commands
The commands in this section can be sent from a host directly to any ACU on a network to trigger Digital Out relays or the beeper.
BELL
Turn on “Good” Beep Syntax: BELLrs Arguments: None. Discussion: Turns on “good” beep (double short beep). Example: BELL^
SO
Turn on “Good” Beep and Green LED Syntax: SOnrs Arguments: n - Reader number (1 or 2) Discussion: Turns on “good” beep (double short beep) and green LED on reader n (n = 1 or 2). Example: SO2^ Turns on “good” beep and green LED on reader 2.
SI
Turn on “Bad” Beep and Yellow LED Syntax: SInrs Arguments: Accu-Time® Series 7000 Access Control Unit User’s Guide
3-26
Page 73
n - Reader number (1 or 2) Discussion: Turns on “bad” beep (single long beep) and yellow LED on reader n (n = 1 or 2). Example: SI2^ Turns on “bad” beep and yellow LED on reader 2.
Accu-Time® Series 7000 Access Control Unit User’s Guide