Page 56
Syntax: LSA01aaaaaaaaaaaars Arguments: aaaaaaaaaaaa - Master badge number. Discussion: This command sets the master badge number that is used to program the Series 7000 when used in stand-alone mode. The badge number should be padded to 12 digits. Example: LSA01000000007965^ Sets master badge number to 7965.
O00
Lock ACU Syntax: O00rs Arguments: None. Discussion: Locks ACU, disallows user input until unlock command O10 received. Example: O00^
O10
Unlock ACU Syntax: O10rs Arguments: None. Discussion: Unlocks ACU and allows user input. Accu-Time® Series 7000 Access Control Unit User’s Guide
3-10
Page 57
Example: O10^
R00
Reset
Syntax: R00 Arguments: None. Discussion: Clears RAM queue, deletes all data, and performs a power-on reset. The ACU’s baud rate setting is not reset. Example: R00^
R01
Reset Syntax: R01 Arguments: None. Discussion: Clears all stored transactions and performs a power-on reset. Any download file stored in the ACU is not deleted. Example: R01^
S00
Get Program Number Syntax: S00rs Arguments: None. Accu-Time® Series 7000 Access Control Unit User’s Guide
3-11
Page 58
Discussion: Returns as a BS00 message the current program number and revision. Example: S00^
S01
Get Number Of Badges And Schedules Syntax: S01rs Arguments: None. Discussion: Returns as a BS01 message the number of badges loaded, number of schedules loaded, largest used badge storage location number, and number of deleted areas (holes) in badge storage area. Example: S01^
S02
Get Badge Information
Syntax: S02bbbbbbbbbbbbrs Arguments: bbbbbbbbbbbb - Badge number for which to get information. Discussion: Returns as a BS02 message the details on a loaded badge number or returns “NOT FOUND” if the badge is not loaded. Returns the badge number, schedule number, last reader swiped, holiday data in hex format, and location number in the badge storage area. Example: S02000000840001^ Returns details for badge number 840001.
Accu-Time® Series 7000 Access Control Unit User’s Guide
3-12
Page 59
S03
Get Badge Information by storage location number Syntax: S03nnnnrs Arguments: nnnn - badge storage location number, as returned by S02 command in a BS02 message. Discussion: Returns as a BS03 message the details on a loaded badge number. If the badge was recently deleted with the LED01 command, the badge number will show ‘ff’ at the start. This indicates that the badge number has been deleted and the memory area has a hole, which will be next filled upon receiving a new employee badge. Note: this ‘ff’ badge will not be validated. If a location number larger than the largest valid badge storage location number (obtained by issuing S01) is queried, then a badge number may be returned from a previous load and look valid (not have ‘ff’ at the start). This will not be validated. Example: S0300074^
Obtains badge details in location 0074.
S04
Get Schedule Information Syntax: S04nnnzrs Arguments: n - Three digit schedule number z - One digit zone number Discussion: Returns as BS04 message the specified schedule and zone information. Example: S040012^ Returns schedule information for schedule number 001 plus the schedule’s zone 2. Accu-Time® Series 7000 Access Control Unit User’s Guide
3-13
Page 60
T00
Set Time/Date Syntax: T00YYMMDDHHMMSSrs Arguments: YY - Two-digit year MM - Two-digit month DD - Two-digit day HH - Two-digit hour (24-hour format) MM - Two-digit minutes SS - Two-digit seconds Discussion: Sets date and time in ACU. Time is in 24-hour format. Example: T00030219101509^ Sets date and time to February 19, 2003, 10:15:09.
T10
Get Time/Date Syntax: T10rs Arguments: None Discussion: Reads the current date and time from ACU. ACU responds with a BT01 message containing current date and time. Example: T10^
T20
Set Daylight Savings Time
Accu-Time® Series 7000 Access Control Unit User’s Guide
3-14
Page 61
Syntax: T20YYMMDDrs Arguments: YY - Two-digit year MM - Two-digit month DD - Two-digit day Discussion: Sets the date where daylight savings time will change. A date between June and December will set back the clock one hour. A date between January and May will advance the clock one hour. Example: T20030330^ Sets date of change to daylight savings time to March 30, 2003.
Accu-Time® Series 7000 Access Control Unit User’s Guide
3-15
Page 62
Employee File Handling Commands
The employee file is used to validate a badge stored in the ACU. When an employee swipes a badge, the ACU will look to see if the badge is present in the employee file. If the badge is found, the ACU will then check to be sure that the badge can be used at that time (check it against the employee’s schedule). If the schedule confirms that access by that badge is valid at that time, the ACU will grant access One other item in the employee file is the supervisor level. The supervisor level is used to define whether or not that employee is a supervisor. This item is here for future use. NEED FORMAT OF SERIES 7000 EMPLOYEE FILE
LEE01
Erase Employee File Syntax: LEE01rs Arguments: None. Discussion: Issuing this command erases the complete employee file stored in the ACU. Use the LED01 command to erase a single employee record. Example: LEE01^
LEC01
Load Employee Records Syntax: LEC01aaaaaaaaaaaabbbc Arguments: aaaaaaaaaaaa - Employee badge number (12 digits). bbb - Schedule number (3 digits). c-
Supervisor level (1 digit). Not yet implemented; set to 1.
Discussion:
Accu-Time® Series 7000 Access Control Unit User’s Guide
3-16
Page 63
This command adds employees to the employee file stored in the ACU. Each load will append to the end of the file. Up to 2500 employee records can be loaded into standard ACU memory. Note: If an employee is to be moved to a different schedule, you must first issue the LED01 (delete) command to remove the badge number then reload the badge with the different schedule number. Example: LEC010000001234560031^ Defines an employee record with badge number 000000123456, schedule number 003, supervisor level 1.
LED01
Erase a Single Employee Syntax: LED01aaaaaaaaaaaars Arguments: aaaaaaaaaaaa - Badge number of employee record to erase. Discussion: Deletes the specified employee record from the employee file stored in the ACU. Use the LEE01 command to erase the complete employee file. Space freed by this command will be reused if you subsequently use the LEC01 command to add a new employee record. Example: LED01000000840012^ Deletes the employee record for badge 840012.
Accu-Time® Series 7000 Access Control Unit User’s Guide
3-17
Page 64
Badge Masking and Validation Commands LEB01
This section lists commands used for badge masking and validation.
Set Badge Mask and Validation Syntax: LEB01abcdxxxxxxxxxxxxnnnrs Arguments: a - 0 = No validation of the badge to the employee file. 1 = Do validate the badge. b - 0 = No mask testing 1 = Check the badge against the mask c - 0 = Positive validation (standard) 1 = Negative file validation d
0 = Not used xxxxxxxxxxxx - This is the 12-character badge mask. A specific character in each position means the badge MUST have that character in that position. ? in any position means don't care, allow any character in that position. DC2 (CTRL/R, 1810, 1216) means there must be an alphabetic character in that position. DC3 (CTRL/S, 1910, 1316) means there must be a numeric character in that position. nnn - Schedule number to test badge against if valid. 000 = Do not test. Discussion: This command sets three operating characteristics of the ACU: • If the badge swiped will be validated against the employee file or not. • If the badge is not to be tested against the employee file, will it be tested against the mask. (A mask is a string of characters the same length as the badge number, with each position of the mask allowing for screening of the badge on a byte-by-byte basis. In other words, each character position
Accu-Time® Series 7000 Access Control Unit User’s Guide
3-18