For the Accu-Time Series 7000

Page 47

Chapter 3

Commands

This chapter explains the commands used to control an Accu-Time Series 7000 access control unit (ACU) when running the standard firmware. This firmware is appropriate for the majority of access control and security applications. Once an ACU is installed, a number of operations are possible depending on its setup. For example, you can: • Swipe or key a badge at a reader / keypad and have the time logged and gain access. • Validate an employee badge number against the ACU’s internal validation tables. This can be a simple badge list or be linked with schedules in order to allow access at certain times to accommodate shift patterns, etc. • Load bell schedules to sound alarms or bells at certain times using the Digital Output options to signal meal times, breaks, etc. The DO options can also be used to trigger door locks. • Use interactive commands to control ACUs directly from a host application. Commands such as BELL and DCxxx (activating the relays) can be sent as and when required across a network. See Interactive commands section. The functions listed above are available on all ACUs from Accu-Time Systems, Inc. You can tailor the functionality of an ACU to your particular requirements using the command set described in this chapter.

Accu-Time® Series 7000 Access Control Unit User’s Guide

3-1

Page 48

Command Syntax

Some commands, to be complete, need information added to them. These command descriptions have a table under them showing the valid choices. Default is the value applied if not modified. Valid range is the acceptable range of input the command will allow. LPB00

###### One or more command arguments, if any

Command Some commands accept one or more arguments. Sometimes an argument is a hexadecimal (base 16) number and the valid range of a single digit may exceed 9. For those instances, use the equivalents in the following table to enter digit values 10 through 15:

Table 3-1: Character Equivalents to Enter Hexadecimal Values Value

Equivalent

10

: (colon)

11

; (semicolon)

12

< (less than)

13

= (equals)

14

> (greater than)

15

? (question mark)

Accu-Time® Series 7000 Access Control Unit User’s Guide

3-2

Page 49

Command Index

This section lists all the commands in alphabetical order, with a brief description.

Table 3-2: Command Index Command

Description

ALDI1

Digital IN 1 alarm message Page 3-31

ALDI2

Digital IN 2 alarm message Page 3-31

ALSTATE

Alarm query message Page 3-32

ALTAMP

Tamper alarm message Page 3-33

AQ10

Get current alarm status Page 3-5

BA01

Normal power recovery message Page 3-33

BA02

Low power message Page 3-34

BELL

Turn on “good” beep Page 3-26

BG00

Initial power-up message Page 3-34

BG01

Power-up recovery message Page 3-35

BS00

Program number request Page 3-36

BS01

Badge and schedule size request Page 3-36

BS02

Badge information request Page 3-37

BS03

Location information request Page 3-38

BS04

Schedule information request Page 3-38

BT01

Time request message Page 3-39

C00

Set up RS485 ports Page 3-5

D10

Set download ID Page 3-6

D20

Get download ID Page 3-6

DC100

Turn off DO_1 Page 3-28

DC101

Turn on DO_1Page 3-28

DC111

Turn on DO_1 for preset time Page 3-28

DC200

Turn off DC_2 Page 3-29

DC201

Turn on DO_2 Page 3-29

DC211

Turn on DO_2 for preset time Page 3-29

DI00

Download ID message Page 3-39

LAP01

Set anti-passback enable Page 3-7

LBC01

Load bell schedules Page 3-21

LBE01

Erase all bell schedules Page 3-24

LDA01

Enable or disable digital inputs Page 3-7

LEB01

Set badge mask and validation Page 3-18

LEC01

Load employee records Page 3-16

LED01

Erase a simple employee Page 3-17

LEE01

Erase employee file Page 3-16

Accu-Time® Series 7000 Access Control Unit User’s Guide

3-3

Page 50

Table 3-2: Command Index (Continued) Command

Description

LHO101

Load holiday schedules Page 3-22

LPB01

Set beeper enable Page 3-7

LPB03

Set relay activation time in milliseconds Page 3-8

LPB04

Set relay activation time in seconds Page 3-8

LPB05

Set digital IN timeout Page 3-9

LSA01

Set master badge number Page 3-9

LSB01

Set schedule start date Page 3-20

LSC01

Load schedules Page 3-21

LSD01

Delete individual schedule Page 3-22

LSE01

Erase all schedules Page 3-20

O00

Lock ACU Page 3-10

O10

Unlock ACU Page 3-10

P....

Employee transaction message Page 3-40

R00

Reset Page 3-11

R01

Reset Page 3-11

S00

Get program number Page 3-11

S01

Get number of badges and schedules Page 3-12

S02

Get badge information Page 3-12

S03

Get badge information by storage location number Page 3-13

S04

Get schedule information Page 3-13

SI

Turn on “bad” beep and yellow LED Page 3-26

SO

Turn on “good” beep and green LED Page 3-26

T00

Set time/date Page 3-14

T10

Get time/date Page 3-14

T20

Set daylight savings time Page 3-14

Accu-Time® Series 7000 Access Control Unit User’s Guide

3-4

Page 51

General Commands AQ10

This section lists general-purpose commands.

Get Current Alarm Status Syntax: AQ10rs Arguments: None. Discussion: Returns status of the Tamper, DI_1, and DI_2 inputs, OK or still active as ALSTATE message. Example: AQ10^

C00

Set Up Serial Ports Syntax: C00nmrs Arguments: n - Baud rate (value from 1 to 5) 1 = 1200 2 = 2400 3 = 4800 4 = 9600 5 = 19200 m - Data bits and parity (value from 0 to 2) 0 = 8 data bits / no parity 1 = 7 data bits / odd parity 2 = 7 data bits / even parity Discussion: The serial ports are set by default to 9600,8,1,N (9600 baud, 8 data bits, 1 stop bit, no parity). Use the C00 command to change the port settings. (The number of stop bits cannot be changed.)

Accu-Time® Series 7000 Access Control Unit User’s Guide

3-5

Page 52

The new settings will take effect only after a power off/on cycle or a RESET command occurs. Example: C0050^ Sets the ports to 9600 baud, 8 data bits, no parity.

D10

Set Download ID Syntax: D10xxxxxxxxrs Arguments: xxxxxxxx - Eight-character alphanumeric ID for the download. Discussion: Sets a download ID so you can later request from the ACU the ID of the last download it received. For instance, if there several .dld files each holding different groups of badges, the D10 command can get the ID of the download that was last sent to an ACU. Example: D10DL000023^ Sets the download ID to DL000023.

D20

Get Download ID Syntax: D20rs Arguments: None. Discussion: Gets the download ID from an ACU, which was previously set by the last download using the D10 command. The ACU responds with a DI00 message. Example: D20^

Accu-Time® Series 7000 Access Control Unit User’s Guide

3-6

Page 53

LAP01

Set Anti-passback Enable Syntax: LAP01ars Arguments: a - 0 = disable anti-passback, 1 = enable anti-passback Discussion: This feature, if enabled, disallows a second access by a particular badge on reader A if the unit has not yet recorded a swipe by that badge on reader B. Example: LAP011^ Enables anti-passback mode.

LDA01

Set Digital Inputs Active/Inactive Syntax: LDA01ars Arguments: a - 0 = disable digital inputs, 1 = enable digital inputs. Discussion: This command enables or disables the digital inputs. Setting a to 1 enables the inputs and 0 disables them. Any other value is ignored. Example: LDA011^ Enables digital inputs.

LPB01

Set Beeper Enable Syntax: LBP01nrs Arguments:

Accu-Time® Series 7000 Access Control Unit User’s Guide

3-7

Page 54

n - 0 = Disable on-board beeper. 1 = Enable on-board beeper. Discussion: The on-board beeper is sounded during validation badge swipes, alarm states, and while in test mode. Setting the argument n to 0 disables the on-board beeper, setting to 1 enables the beeper. Example: LPB011^ Enables on-board beeper.

LPB03

Set Relay Activation Time in Milliseconds Syntax: LPB03aaaabbbbrs

Arguments: aaaa - Amount of time, in milliseconds, to activate relay D01. Enter 0000 to disable. bbbb - Amount of time, in milliseconds, to activate relay D02. Enter 0000 to disable. Discussion: This command sets the amount of time the DO_1 and DO_2 relays will remain activated after reading a valid badge. The valid time range is from 0.001 to 9.999 seconds. Specify the time, in milliseconds, from 0001 to 9999. The value aaaa sets the time in milliseconds the DO_1 relay will be active. The value bbbb is used for the DO_2 relay. Entering 0000 disables a relay, thus NOT activating it after a valid badge swipe. You must specify 4 digits. Note: See also the LPB04 command below, which lets you set the relay activation time in seconds to allow longer periods of operation. Example: LPB0305000250^ Activates relay D01 for 500 milliseconds and relay D02 for 250 milliseconds.

LPB04

Set Relay Activation Time in Seconds Syntax: LPB04aabbrs Accu-Time® Series 7000 Access Control Unit User’s Guide

3-8

Page 55

Arguments: aa - Amount of time, in seconds, to activate relay D01. Enter 00 to disable. bb - Amount of time, in seconds, to activate relay D02. Enter 00 to disable. Discussion: This command sets the amount of time the DO_1 and DO_2 relays will remain activated after reading a valid badge. The valid time range is from 01 to 99 seconds. Specify the time, in seconds, from 01 to 99. The value aa sets the time in seconds the DO_1 relay will be active. The value bb is used for the DO_2 relay. Entering 00 disables a relay, thus NOT activating it after a valid badge swipe. You must specify 2 digits. Note: See also the LPB03 command above, which lets you set the relay activation time in milliseconds to allow shorter periods of operation. Example: LPB040520^ Activates relay D01 for 5 seconds and relay D02 for 20 seconds.

LPB05

Set Digital IN Timeout Syntax: LPB05aaabbbrs Arguments: aaa - Amount of time, in seconds, to wait for Digital IN 1. Enter 000 to disable. bbb - Amount of time, in seconds, to wait for Digital IN 2. Enter 000 to disable. Discussion: This command sets the amount of time that DI_1 and DI_2 will wait for input until the ACU enters alarm mode and sends an alarm message to the host. aaa is used for DI_1. bbb is used for DI_2. Valid time range is 001 to 999 seconds. Setting an argument to 000 disables timeout for that DI. Example: LPB05010020^ Sets DI_1 wait for input to 10 seconds and DI_2 wait to 20 seconds.

LSA01

Set Master Badge Number

Accu-Time® Series 7000 Access Control Unit User’s Guide

3-9