Page 83
Syntax: BS01usbbbbussssusmmmmushhhhusYYMMDDHHMMSSrs Arguments: bbbb = Number of badges loaded sss = Number of schedules loaded mmmm = Largest valid badge storage location number hhhh = Total number of “holes” in the used badge storage area YY - Two-digit year MM - Two-digit month DD - Two-digit day HH - Two-digit hour (24-hour format) MM - Two-digit minutes SS - Two-digit seconds Discussion: Response to S02 command badge and schedule request. Note: (mmmm – hhhh) should equal bbbb. Example: BS01v0250v005v0260v0010v030419085347^ (bbbb = 0250, sss = 005, mmmm = 0260, hhhh = 0010.)
BS02
Badge Information Request (response to S02 command) Syntax: BS02usaaaaaaaaaaaausbbbsohcsohddsoheeeeers Arguments: aaaaaaaaaaaa - Badge number loaded bbb - Schedule number currently active c - Last reader swiped
Accu-Time® Series 7000 Access Control Unit User’s Guide
3-37
Page 84
dd - Holiday data in hexadecimal format eeeee - Badge storage location number Discussion: Response to S02 command badge information request. Example: BS02v000000007965v003☺0☺00☺00260^ Badge number 7965, schedule 003, reader 0, holiday data 00, storage location number 00260.
BS03
Location Information Request (response to S03 command) Syntax: BS03usaaaaaaaaaaaausbbbsohcsohddsoheeeeers Arguments: aaaaaaaaaaaa = badge number loaded bbb = schedule number currently active c = last reader swiped dd = holiday data in hexadecimal format eeeee = storage location number Discussion: Response to S03 command location information request. Example: BS03v000000007965v003☺0☺00☺00260^ Badge number 7965, schedule 003, reader 0, holiday data 00, storage location number 00260.
BS04
Schedule Information Request (response to S04 command) Syntax: BS04usaaabuscccccdddddrs Arguments: Accu-Time® Series 7000 Access Control Unit User’s Guide
3-38
Page 85
aaa - Schedule number b - Schedule zone number – starts at 0 ccccc - Start minutes of zone ddddd - End minutes of zone Discussion: Response to S04 command schedule information request. Example: BS04v0031v0480005340^ Schedule number 3, zone 1, start 04800 (Thursday, 8:00am), end 05340 (Thursday, 5:00pm).
BT01
Time Request Message Syntax: BT01YYMMDDHHMMSSrsusYYMMDDHHMMSSrs Arguments: YY - Two-digit year MM - Two-digit month DD - Two-digit day HH - Two-digit hour (24-hour format) MM - Two-digit minutes SS - Two-digit seconds Discussion: Message sent from ACU to host in response to a T10 get time request from host. The two timestamps are the same and are the date/time and stored in the ACU. Example: BT01030419114503^v030419114503^ The ACU reports its time as April 19, 2003, 11:45:03.
DI00
Download ID Message Accu-Time® Series 7000 Access Control Unit User’s Guide
3-39
Page 86
Syntax: DI00usaaaaaaaars Arguments: aaaaaaaa - Download ID Discussion: Message sent by ACU to host to return the download ID that was initially set with the D10 command. Example: DI00vDL000023^ Download ID = DL000023.
P....
Employee Transaction Message Syntax: PeSnnnrsbbbbbbbbbbbbrsusYYMMDDHHMMSSrsnrs Arguments: P - First character = P signifies employee transaction. e - Type of entry. B = badge entry, K = keyboard entry. S - Third character = S signifies standard punch. nnn - Valid/invalid badge. 000 = badge swiped was valid. 999 = badge swiped was invalid or denied access. bbbbbbbbbbbb - Employee number (badge number). YY - Two-digit year MM - Two-digit month DD - Two-digit day HH - Two-digit hour (24-hour format) MM - Two-digit minutes SS - Two-digit seconds n - Reader number (0 or 1). Accu-Time® Series 7000 Access Control Unit User’s Guide
3-40
Page 87
Discussion: Each transaction message received by the host from an ACU contains a timestamp of the date and time the event occurred. The examples below show how transaction messages are formatted. Example: PBS000^000000123456^v030412141753^0^ Employee swiped badge number 000000123456 on reader 0 at 14:17:53 pm April 12, 2003. The badge was valid. PBS999^000000123456^v030414061902^1^ Employee swiped badge number 000000123456 on reader 1 at 6:19:02 on April 14, 2003. The badge was invalid. Note: The actual strings received from the ACU will contain two additional characters at the end, which are not used and can be ignored when processing the data.
Accu-Time® Series 7000 Access Control Unit User’s Guide
3-41
Page 88
General Command Syntax Notes
1.Date and time stamp is preceded by a us = unit separator (1F HEX) 2.All messages end with rs = record separator (1E HEX) 3.All messages to ACU must not exceed a maximum message length of 250 characters. 4.All messages transmitted and received start with a header which consists of: \B!gs \ back slash (5C HEX) B application type (default is B) (41 HEX - 4A HEX) ! ACU address selected by onboard DIP switches (Sw2 Pos4-8) gs group separator (1D hex) Note: Appendix B shows a table with the single character addressing that is used to identify individual ACUs from the polled transaction data.
Accu-Time® Series 7000 Access Control Unit User’s Guide
3-42