Page 89

Appendix A

Minute Offsets

Table A-1 shows the minute offset from Sunday midnight for each hour of the week for use in the schedule command.(LSC01). The value used as the schedule offset should be a five-digit number padded with leading zeros. Add the minutes of a partial hour to the figure in the table below (e.g. 01:45 on Tuesday would be 1500 + 45, or 01545).

Accu-Time® Series 7000 Access Control Unit User’s Guide

A-1

Page 90

Table A-1: Schedule Minutes Offset MON

TUE

WED

THU

FRI

SAT

SUN

00:00

0

1440

2880

4320

5760

7200

8640

01:00

60

1500

2940

4380

5820

7260

8700

02:00

120

1560

3000

4440

5880

7320

8760

03:00

180

1620

3060

4500

5940

7380

8820

04:00

240

1680

3120

4560

6000

7440

8880

05:00

300

1740

3180

4620

6060

7500

8940

06:00

360

1800

3240

4680

6120

7560

9000

07:00

420

1860

3300

4740

6180

7620

9060

08:00

480

1920

3360

4800

6240

7680

9120

09:00

540

1980

3420

4860

6300

7740

9180

10:00

600

2040

3480

4920

6360

7800

9240

11:00

660

2100

3540

4980

6420

7860

9300

12:00

720

2160

3600

5040

6480

7920

9360

13:00

780

2220

3660

5100

6540

7980

9420

14:00

840

2280

3720

5160

6600

8040

9480

15:00

900

2340

3780

5220

6660

8100

9540

16:00

960

2400

3840

5280

6720

8160

9600

17:00

1020

2460

3900

5340

6780

8220

9660

18:00

1080

2520

3960

5400

6840

8280

9720

19:00

1140

2580

4020

5460

6900

8340

9780

20:00

1200

2640

4080

5520

6960

8400

9840

21:00

1260

2700

4140

5580

7020

8460

9900

22:00

1320

2760

4200

5640

7080

8520

9960

23:00

1380

2820

4260

5700

7140

8580

10020

Accu-Time® Series 7000 Access Control Unit User’s Guide

A-2

Page 91

Appendix B

Pinouts, Interfaces, and Switches

This appendix describes the connector pinouts, interfaces, and switches of the Series 7000 access control unit (ACU).

Pinouts 12V Power Input

Connector type: 2.5mm socket Pinout: Negative outside, positive inside

RS232 Network

Connector type: RJ45 socket – 8 contact

Table B-1: RS232 Pinouta Pin Number Description a

1

Earth ground

2

Receive data

3

Transmit data

4

N/C

5

N/C

6

Ground

7

Link to pin 7 on RS485 network plug

8

Ground

Pinouts are referenced to the terminal.

Accu-Time® Series 7000 Access Control Unit User’s Guide

B-1

Page 92

RS485 Network

Connector type: 2 RJ45 sockets – 8 contact

Table B-2: RS485 Pinouta Pin Number

Description

1

Earth ground

2

Network data in –

3

Network data out +

4

Network data out –

5

Network data in +

6

Ground

7

Link to pin 7 on RS232 network plug

8

Ground a Pinouts are referenced to the terminal.

Battery Status Inputs

Connector type: 3.5mm pitch screw terminal plug – 4 contact (Note: For future use.)

Table B-3: Battery Status Pinout Pin Number

Description

1

Ground

2

Battery on (power failure) signal from UPS

3

Battery low signal from UPS

4

Chassis

Accu-Time® Series 7000 Access Control Unit User’s Guide

B-2

Page 93

DIP Switches DIP Switch 1 Table B-4: DIP Switch 1 Settings Number On (1)

Off (0)

1

Test Switch Disable

Test Switch Enable

2

Tamper Switch Disable

Tamper Switch Enable

3

Factory Default Unit Reset

Normal Operation

4

RS232 Mode

RS485 Mode

5

Reserved – set OFF

6

Dual Door Mode

Single Door Mode

7

Reserved

Normal Operation

8

On-Line

Stand-Alone

DIP Switch 2 Table B-5: DIP Switch 2 Settings Number Description 1–2

3 4–8

Reader 0 type

Reader 1 type (Binary Unit Address)

Valuea 00b

Mag Stripe/Prox Reader

01b

Mag Stripe/Prox Reader

10

Barcode Reader

11

Keypad

0

Same as reader 1

1

Exit Button

00001

Address = 1

00010

Address = 2

00000

Address = 32 a 0 = OFF, 1 = ON. b There is no difference in functionality between a setting of 00 and a setting of 01 for switches 1-2.

IMPORTANT: For a magnetic or proximity reader or for a keyboard, the board jumpers must be placed in the upper position. For barcode readers, the jumpers must be placed in the lower position. See Figure 1-3 on page 1-7.

Accu-Time® Series 7000 Access Control Unit User’s Guide

B-3

Page 94

Standard Reader Connections Reader 7000/101 and 102 Wiring (Mag Stripe and HiTag Proximity)

This section gives the wire color code and corresponding pinout for the readers supported by ATS for use with the Series 7000 ACU.

Table B-6: Reader 7000/101 and 7000/102 Wiring Reader 0/1 Pin Number

Reader Wire Color

1

Shield

2

White and Black

3

N/Ca

4

N/C

5

Green

6

Brown

7

Orange

8

N/C

9

Yellow

10

Purple

11

Blue

12

Red a N/C = not connected

Accu-Time® Series 7000 Access Control Unit User’s Guide

B-4

Page 95

Keypad 7000/103 Table B-7: Keypad 7000/103 Wiring (Storm) Reader 0/1 Pin Number Keypad Wire Color 1

N/Ca

2

N/C

3

N/C

4

Green

5

Pink

6

Grey

7

Brown

8

N/C

9

Orange

10

Purple

11

Blue

12

N/C a N/C = not connected

Accu-Time® Series 7000 Access Control Unit User’s Guide

B-5

Page 96

HID “Clock and Data” Reader Wiring

The following table shows the wiring details for connecting a clock-and-data interface HID Prox-Point Plus reader (P/N: 6008B) to an ATS Series 7000 ACU.

Table B-8: HID ProxPoint Plus “Clock and Data” Reader Wiring Pin Number

Wire Color

Function

1

Shield (Black) Shielda

2

Black

3

N/Cb

4

N/C

5

Orange

Green LED

6

Brown

Red LED

7

N/C

8

N/C

9

Green

Data

10

Purple

Card Present

11

White

Clock

12

Red

+5V

Ground a The shield wire is usually covered with a black sheath and should not be conb fused with the 0V ground wire of the same color. N/C = not connected.

Accu-Time® Series 7000 Access Control Unit User’s Guide

B-6

Page 97

Barcode Readers (ATS Weather Resistant 9001/ XX)

The supplied reader cables use one of two wire color codes, depending on the date of the cable’s manufacture. Table B-9 lists both color codes.

Table B-9: Barcode Readers 9001/XX Wiring Wire Color Pin Number Code A 1

N/Ca

2

Yellow

3 a

N/C

4

N/Ca

5

N/Ca

6

Black

7 a

N/C

8

N/Ca

9

Red

10

Link to pin 2b

11

N/Ca

12

Green

Wire Color Code B

Function

Blue

Ground

White/Blue

Red LED (if supported)

White/Orange

Data

Orange

+5 VDC a N/C = not connected b For barcode reader. Pin 10 of reader 1 connector can be used for exit button input if DIP switch 2 #3 is set to 1. See DIP Switches on page B-3.

The cables that come with ATS 9001/xx readers may have attached modular plugs, but the reader interfaces of the 7000 have only screw-down connectors for separate wires. If the cables that come with your readers have attached plugs, cut the modular plugs off the cables, strip the wires as shown in the section Connecting the Reader and DI/DO Wiring on page 2-6, and route the color-coded wires to the correct pins of the screw-down connectors.

Accu-Time® Series 7000 Access Control Unit User’s Guide

B-7