The text of a manual · part 11 of 13
Accu-Time Series 7000 Access Control Unit User's Manual, pages 89 to 97
Pages 89 to 97 of 105: Appendix A Minute Offsets; Appendix B Pinouts, Interfaces, and Switches
The original document is the PDF (1.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Accu-Time Series 7000
Page 89
Appendix A
Minute Offsets
Table A-1 shows the minute offset from Sunday midnight for each hour of the week for use in the schedule command.(LSC01). The value used as the schedule offset should be a five-digit number padded with leading zeros. Add the minutes of a partial hour to the figure in the table below (e.g. 01:45 on Tuesday would be 1500 + 45, or 01545).
Accu-Time® Series 7000 Access Control Unit User’s Guide
A-1
Page 90
Table A-1: Schedule Minutes Offset MON
TUE
WED
THU
FRI
SAT
SUN
00:00
0
1440
2880
4320
5760
7200
8640
01:00
60
1500
2940
4380
5820
7260
8700
02:00
120
1560
3000
4440
5880
7320
8760
03:00
180
1620
3060
4500
5940
7380
8820
04:00
240
1680
3120
4560
6000
7440
8880
05:00
300
1740
3180
4620
6060
7500
8940
06:00
360
1800
3240
4680
6120
7560
9000
07:00
420
1860
3300
4740
6180
7620
9060
08:00
480
1920
3360
4800
6240
7680
9120
09:00
540
1980
3420
4860
6300
7740
9180
10:00
600
2040
3480
4920
6360
7800
9240
11:00
660
2100
3540
4980
6420
7860
9300
12:00
720
2160
3600
5040
6480
7920
9360
13:00
780
2220
3660
5100
6540
7980
9420
14:00
840
2280
3720
5160
6600
8040
9480
15:00
900
2340
3780
5220
6660
8100
9540
16:00
960
2400
3840
5280
6720
8160
9600
17:00
1020
2460
3900
5340
6780
8220
9660
18:00
1080
2520
3960
5400
6840
8280
9720
19:00
1140
2580
4020
5460
6900
8340
9780
20:00
1200
2640
4080
5520
6960
8400
9840
21:00
1260
2700
4140
5580
7020
8460
9900
22:00
1320
2760
4200
5640
7080
8520
9960
23:00
1380
2820
4260
5700
7140
8580
10020
Accu-Time® Series 7000 Access Control Unit User’s Guide
A-2
Page 91
Appendix B
Pinouts, Interfaces, and Switches
This appendix describes the connector pinouts, interfaces, and switches of the Series 7000 access control unit (ACU).
Pinouts 12V Power Input
Connector type: 2.5mm socket Pinout: Negative outside, positive inside
RS232 Network
Connector type: RJ45 socket – 8 contact
Table B-1: RS232 Pinouta Pin Number Description a
1
Earth ground
2
Receive data
3
Transmit data
4
N/C
5
N/C
6
Ground
7
Link to pin 7 on RS485 network plug
8
Ground
Pinouts are referenced to the terminal.
Accu-Time® Series 7000 Access Control Unit User’s Guide
B-1
Page 92
RS485 Network
Connector type: 2 RJ45 sockets – 8 contact
Table B-2: RS485 Pinouta Pin Number
Description
1
Earth ground
2
Network data in –
3
Network data out +
4
Network data out –
5
Network data in +
6
Ground
7
Link to pin 7 on RS232 network plug
8
Ground a Pinouts are referenced to the terminal.
Battery Status Inputs
Connector type: 3.5mm pitch screw terminal plug – 4 contact (Note: For future use.)
Table B-3: Battery Status Pinout Pin Number
Description
1
Ground
2
Battery on (power failure) signal from UPS
3
Battery low signal from UPS
4
Chassis
Accu-Time® Series 7000 Access Control Unit User’s Guide
B-2
Page 93
DIP Switches DIP Switch 1 Table B-4: DIP Switch 1 Settings Number On (1)
Off (0)
1
Test Switch Disable
Test Switch Enable
2
Tamper Switch Disable
Tamper Switch Enable
3
Factory Default Unit Reset
Normal Operation
4
RS232 Mode
RS485 Mode
5
Reserved – set OFF
6
Dual Door Mode
Single Door Mode
7
Reserved
Normal Operation
8
On-Line
Stand-Alone
DIP Switch 2 Table B-5: DIP Switch 2 Settings Number Description 1–2
3 4–8
Reader 0 type
Reader 1 type (Binary Unit Address)
Valuea 00b
Mag Stripe/Prox Reader
01b
Mag Stripe/Prox Reader
10
Barcode Reader
11
Keypad
0
Same as reader 1
1
Exit Button
00001
Address = 1
00010
Address = 2
00000
Address = 32 a 0 = OFF, 1 = ON. b There is no difference in functionality between a setting of 00 and a setting of 01 for switches 1-2.
IMPORTANT: For a magnetic or proximity reader or for a keyboard, the board jumpers must be placed in the upper position. For barcode readers, the jumpers must be placed in the lower position. See Figure 1-3 on page 1-7.
Accu-Time® Series 7000 Access Control Unit User’s Guide
B-3
Page 94
Standard Reader Connections Reader 7000/101 and 102 Wiring (Mag Stripe and HiTag Proximity)
This section gives the wire color code and corresponding pinout for the readers supported by ATS for use with the Series 7000 ACU.
Table B-6: Reader 7000/101 and 7000/102 Wiring Reader 0/1 Pin Number
Reader Wire Color
1
Shield
2
White and Black
3
N/Ca
4
N/C
5
Green
6
Brown
7
Orange
8
N/C
9
Yellow
10
Purple
11
Blue
12
Red a N/C = not connected
Accu-Time® Series 7000 Access Control Unit User’s Guide
B-4
Page 95
Keypad 7000/103 Table B-7: Keypad 7000/103 Wiring (Storm) Reader 0/1 Pin Number Keypad Wire Color 1
N/Ca
2
N/C
3
N/C
4
Green
5
Pink
6
Grey
7
Brown
8
N/C
9
Orange
10
Purple
11
Blue
12
N/C a N/C = not connected
Accu-Time® Series 7000 Access Control Unit User’s Guide
B-5
Page 96
HID “Clock and Data” Reader Wiring
The following table shows the wiring details for connecting a clock-and-data interface HID Prox-Point Plus reader (P/N: 6008B) to an ATS Series 7000 ACU.
Table B-8: HID ProxPoint Plus “Clock and Data” Reader Wiring Pin Number
Wire Color
Function
1
Shield (Black) Shielda
2
Black
3
N/Cb
4
N/C
5
Orange
Green LED
6
Brown
Red LED
7
N/C
8
N/C
9
Green
Data
10
Purple
Card Present
11
White
Clock
12
Red
+5V
Ground a The shield wire is usually covered with a black sheath and should not be conb fused with the 0V ground wire of the same color. N/C = not connected.
Accu-Time® Series 7000 Access Control Unit User’s Guide
B-6
Page 97
Barcode Readers (ATS Weather Resistant 9001/ XX)
The supplied reader cables use one of two wire color codes, depending on the date of the cable’s manufacture. Table B-9 lists both color codes.
Table B-9: Barcode Readers 9001/XX Wiring Wire Color Pin Number Code A 1
N/Ca
2
Yellow
3 a
N/C
4
N/Ca
5
N/Ca
6
Black
7 a
N/C
8
N/Ca
9
Red
10
Link to pin 2b
11
N/Ca
12
Green
Wire Color Code B
Function
Blue
Ground
White/Blue
Red LED (if supported)
White/Orange
Data
Orange
+5 VDC a N/C = not connected b For barcode reader. Pin 10 of reader 1 connector can be used for exit button input if DIP switch 2 #3 is set to 1. See DIP Switches on page B-3.
The cables that come with ATS 9001/xx readers may have attached modular plugs, but the reader interfaces of the 7000 have only screw-down connectors for separate wires. If the cables that come with your readers have attached plugs, cut the modular plugs off the cables, strip the wires as shown in the section Connecting the Reader and DI/DO Wiring on page 2-6, and route the color-coded wires to the correct pins of the screw-down connectors.
Accu-Time® Series 7000 Access Control Unit User’s Guide
B-7