Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 12 of 13

Accu-Time Series 7000 Access Control Unit User's Manual, pages 98 to 101

Pages 98 to 101 of 105: Appendix C Terminal Addresses; Appendix D Sample Download File

The original document is the PDF (1.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Accu-Time Series 7000

Page 98

Appendix C

Terminal Addresses

You set a Series 7000 ACU serial network address using DIP switch 2, positions 4 through 8. That address is represented in the header of each transaction message sent from an ACU to the host as the character shown in the right-hand column of Table C-1. For example, the character # will appear in transaction messages sent from an ACU with DIP switch 2 positions 4 through 8 set to 3. (0112)

Table C-1: Network Controller ID Addressing Table ACU/Network Controller ID (DIP Switch 2 Positions 4-8) 0 = OFF, 1 = ON

Transaction Header Address

1 (00001) ! 2 (00010) " 3 (00011) # 4 (00100) $ 5 (00101) % 6 (00110) & 7 (00111) ' 8 (01000) ( 9 (01001) ) 10 (01010) * 11 (01011) + 12 (01100) , 13 (01101) 14 (01110) . 15 (01111) / 16 (10000) 0 Accu-Time® Series 7000 Access Control Unit User’s Guide

C-1

Page 99

Table C-1: Network Controller ID Addressing Table 17 (10001) 1 18 (10010) 2 19 (10011) 3 20 (10100) 4 21 (10101) 5 22 (10110) 6 23 (10111) 7 24 (11000) 8 25 (11001) 9 26 (11010) : 27 (11011) ; 28 (11100) < 29 (11101) = 30 (11110) > 31 (11111) ? 32 (00000) @

Accu-Time® Series 7000 Access Control Unit User’s Guide

C-2

Page 100

Appendix D

Sample Download File

Figure D-1 shows a sample download for a Series 7000 ACU running the standard firmware (200 version EPROM). Refer to Table 1 on page xii for definitions of the special character symbols used in the example. Comment lines appear in the example as /* .... */. These are ignored during processing. Two lines in the example, identified by comments, wrap on the page because of their length. The lines in the actual download file do not, in fact, have line breaks in them.

Figure D-1:Sample Download File /* Test 7000 ACU download*/ /*Lock ACU*/ O00^ /*Erase Employee and Schedule Files*/ LEE01^ LSE01^ LBE01^ /*Set Date & Time on ACU*/ T00030716132300^ /*Set Beeper Enable*/ LBP011^ /*Enable Anti-PassBack*/ LAP010^ /*Set Configuration Parameters*/ LPB00001^

Accu-Time® Series 7000 Access Control Unit User’s Guide

D-1

Page 101

/*Setup RS485 Ports*/ /*C0060^*/ /*Set Relay Activation Time, DO1 & DO2*/ LPB0330003000^ /*Set Digital In Timeout*/ /*LPB05060060^*/ /*Set Schedule Start*/ LSB01010101^ /*Set download ID*/ D1012345678^ /*Set Daylight Savings*/ /*T20030328^*/ /*Set Badge Filtering*/ /*LPB0455^*/ /*Load Schedule File*/ LSC01001 0054001020 0192002460 0236003900 0480005340 0624006780^ /* Next line wraps on page; treat as a single line */ LSC01003 0000000360 0144001800 0288003240 0432004680 0576006120 0720007560 0864009000^ LSC01002 0108001300 0252002740 0396004180^ LSC01004 0006000120^ /*Set Validation*/ LEB011000

000^

/*Load Employee File*/ LEC010000000000010001^ LEC010000001234560001^ LEC010000000013780001^ LEC010000000000090001^ /* Load Bell Schedules (LBC01dmmmmtt) */ /* Next line wraps on page; treat as a single line */ /*LBC01100613000623000633000643000653000663000673000683000693000703000713000723 0007330007430007530007630007730007830007930008030^*/ /*Request Time & Date from ACU*/ T10^ /*Request Download ID*/ D20^ /*Request Program Number*/ S00^ /*Request Number of Badges & Schedules*/ S01^ /*Unlock ACU*/ O10^

Accu-Time® Series 7000 Access Control Unit User’s Guide

D-2