Operating Instructions CLP100 Bar Code Reader
Manual58 pagesPDF 1.3 MB
Operating instructions for the SICK CLP100 compact CCD bar code reader: installation, wiring, startup, configuration and maintenance.
Covers · 1 model
The models it covers
Summary
What is in it
SICK's operating instructions for the CLP100 Bar Code Reader, a compact fixed-mount CCD reader that detects and decodes bar codes and sends the result to a host computer. It covers safety information, product design and features, mounting and adjusting the device and its reading-pulse sensor, electrical installation, startup and configuration with the CLP Setup software or command strings, default settings, maintenance, troubleshooting, and technical data with reading field and dimensional drawings.
Its parts
- Notes on this document
- Safety information
- Product description
- Installation
- Electrical installation
- Startup and configuration
- Maintenance
- Troubleshooting
- Technical data
From the manual
Key facts from this manual
Each line names its page in the PDF.
Operating instructions for the SICK CLP100 CCD bar code reader, in versions with a front or side reading window and a cable with a 9-pin D-Sub plug or open end. It explains mounting, wiring the power, serial interfaces and switching signals, quick startup, configuration with the CLP Setup software, troubleshooting and the technical data.
- Device
- Fixed-mount CCD bar code reader with an integrated decoder p. 11
- Variants
- CLP100-0010 (order no. 1018331) front window, D-Sub plug; CLP100-2010 (1018332) side window, D-Sub plug; CLP100-0110 (1018333) front window, open cable end; CLP100-2110 (1018334) side window, open cable end p. 13
- Supply voltage
- 5 V DC ± 5 %, from a supply of at least 2 W p. 13
- Current draw
- 350 mA reading, 150 mA standby p. 43
- Interfaces
- Host RS 232 and auxiliary RS 232 TTL serial interfaces, one switching input for the reading pulse, one switching output for the reading status p. 14
- Data rate
- 1,200 to 19,200 Bd; default 9,600 Bd, 8 data bits, no parity, 1 stop bit p. 35, 43
- D-Sub pinout
- 1 Sensor, 2 RxD (Host), 3 TxD (Host), 4 Result, 5 GND, 6 not assigned, 7 RxD (Terminal) TTL, 8 TxD (Terminal) TTL, 9 +5 V p. 24
- Cable
- 0.9 m (2.95 ft), ending in a 9-pin D-Sub plug or open wires p. 24
- Light and scan rate
- Visible red light (630 nm), LED class 1; 500 Hz scanning/decoding p. 43
- Resolution
- 0.15 to 1.0 mm (5.9 to 39.5 mil); reading area 80 mm (3.15 in) wide at 40 mm (1.58 in) p. 14, 43
- Codes
- All common bar codes; up to 10 codes per reading pulse; code length up to 32 digits p. 43
- Temperature
- 0 to +40 °C operating, −20 to +70 °C storage; 30 to 85 % humidity, non-condensing p. 43
- Housing and weight
- Metal housing, IP 40, approx. 200 g (7.05 oz) p. 43
- Software
- CLP Setup configuration software for Windows 95, 98, NT, 2000 or XP; firmware and CLP Setup from V 1.10 p. 2, 13
What this manual walks you through
- Connecting the 5 V supply voltage p. 25
- Connecting a PC to the RS 232 host interface p. 25, 26
- Wiring the auxiliary (terminal) interface p. 27
- Wiring an external trigger sensor to the Sensor input p. 27
- Wiring the Result switching output p. 28
- Quick-Start with the factory default setting p. 29
- Configuring the reader with CLP Setup and storing the parameter set p. 30
- Viewing and restoring the default setting p. 35
- Reading the red and green status LEDs p. 16
- Troubleshooting power, triggering, reading and data output faults p. 41, 42
Good to know
- The housing must not be opened. p. 25
- Wrong wiring of the host interface can damage the electronics; check the wiring before switching on. p. 26
- The RS 232 host link should be no longer than 12 m (39.37 ft) at up to 19,200 Bd. p. 25
- The auxiliary (terminal) interface uses TTL levels. p. 27
- The user cannot repair the reader, but can replace it. p. 42
Questions this manual answers
What power supply does the SICK CLP100 need?
A stabilized 5 V DC ± 5 % supply giving at least 2 W; the reader draws 350 mA while reading and 150 mA on standby. p. 13, 43
What are the CLP100 default serial settings?
9,600 Bd, 8 data bits, no parity and 1 stop bit, with STX as start character and ETX as stop character. p. 35
What cable connects a CLP100 to a PC?
An RS-232 null modem cable, with RxD and TxD transposed, to a COM port of the PC. p. 26
What can the CLP100 Result output switch?
It is an NPN output switching against GND, rated 5 to 30 V and up to 50 mA, and is not electrically separated. p. 28
Why do the CLP100 LEDs stay dark at power-on?
Either the reader gets no supply voltage or its self-test found a device fault; after a good self-test the LEDs light for three seconds. p. 41
Contents
Chapters and sections
Each line opens the PDF at its page.
- 1 Notes on this document6
- 2 Safety information8
- 3 Product description11
- 4 Installation17
- 5 Electrical installation23
- 6 Startup and configuration29
- 7 Maintenance37